Olga S. Shokhina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Olga S. Shokhina has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Anna S. Sergeeva
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
4 shared publications - Olga S. Golynets
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
3 shared publications - M. P. Krasheninina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
2 shared publications - Anastasiya E. Tyurnina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
1 shared publication - Andrei M. Nepomiluev
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
1 shared publication - Artyom P. Shipitsyn
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
1 shared publication
Latest Publications
- Open Access
- 8 October 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 22 (3) , 51-67
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine | Shipitsyn | Measurement Standards. Reference Materials Применение метода дифференциальной сканирующей калориметрии для исследования и разработки стандартных образцов температуры фазовых переходов органических веществ на основе бензофенона, бензойной кислоты и кофеина | Шипицын | Эталоны. Стандартные образцы
- 8 October 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 22 (3) , 51-67
Open AccessApplication of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine | Shipitsyn | Measurement Standards. Reference Materials Применение метода дифференциальной сканирующей калориметрии для исследования и разработки стандартных образцов температуры фазовых переходов органических веществ на основе бензофенона, бензойной кислоты и кофеина | Шипицын | Эталоны. Стандартные образцы
- Open Access
- 25 December 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 20 (4) , 36-56
Development of Reference Materials of Benzoic and Sorbic Acids
The article introduces the development of reference materials of benzoic and sorbic acids with a certified value of the mass fraction of the main substance. The development of reference materials was carried out in several stages: identification, characterization, study of homogeneity and stability of reference materials. Identification of candidate materials for reference materials was carried out by IR Fourier spectroscopy and determination of melting point by differential thermal analysis. The candidate materials for reference materials were characterized by the indirect method «one hundred minus the sum of impurities» with confirmation of the measurement results by the direct method – the acid-base titration method. It was established that the measurement results of the mass fraction of the main substance of benzoic and sorbic acids obtained by the acid-base titration method and the mass balance method are consistent with each other taking into account the values of expanded uncertainties. The work was carried out using primary and secondary standards. The accuracy of the measurement results of the mass fraction of the main substance was increased by searching for and selecting optimal measurement modes when determining each type of impurity. The homogeneity of materials was determined using the one-way analysis of variance method; stability was determined using the regression analysis method.The developed reference materials of benzoic and sorbic acids were included in the Federal Information Fund for Ensuring the Uniformity of Measurements as GSO 12297–2023 and GSO 12298–2023. The certified value of the mass fraction of the main substance is in the range from 95.00 to 100.00 %, the limits of the permissible values of the absolute error at P = 0.95 are ± 0.5 %.The use of GSO 12297–2023 and GSO 12298–2023 for certification and control of the accuracy of methods, establishment and control of the stability of calibration characteristics of measuring instruments, verification, calibration of measuring instruments can improve the quality of food products, food raw materials and pharmaceuticals.
- 25 December 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 20 (4) , 36-56
Open AccessDevelopment of Reference Materials of Benzoic and Sorbic Acids
The article introduces the development of reference materials of benzoic and sorbic acids with a certified value of the mass fraction of the main substance. The development of reference materials was carried out in several stages: identification, characterization, study of homogeneity and stability of reference materials. Identification of candidate materials for reference materials was carried out by IR Fourier spectroscopy and determination of melting point by differential thermal analysis. The candidate materials for reference materials were characterized by the indirect method «one hundred minus the sum of impurities» with confirmation of the measurement results by the direct method – the acid-base titration method. It was established that the measurement results of the mass fraction of the main substance of benzoic and sorbic acids obtained by the acid-base titration method and the mass balance method are consistent with each other taking into account the values of expanded uncertainties. The work was carried out using primary and secondary standards. The accuracy of the measurement results of the mass fraction of the main substance was increased by searching for and selecting optimal measurement modes when determining each type of impurity. The homogeneity of materials was determined using the one-way analysis of variance method; stability was determined using the regression analysis method.The developed reference materials of benzoic and sorbic acids were included in the Federal Information Fund for Ensuring the Uniformity of Measurements as GSO 12297–2023 and GSO 12298–2023. The certified value of the mass fraction of the main substance is in the range from 95.00 to 100.00 %, the limits of the permissible values of the absolute error at P = 0.95 are ± 0.5 %.The use of GSO 12297–2023 and GSO 12298–2023 for certification and control of the accuracy of methods, establishment and control of the stability of calibration characteristics of measuring instruments, verification, calibration of measuring instruments can improve the quality of food products, food raw materials and pharmaceuticals.
- Open Access
- 22 November 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 18 (2) , 35-56
Development of Measurement Procedures for the Characterization of Reference Materials for Carbohydrate Composition of Dairy Products
This article studies the development of measurement procedures based on various methods for a comprehensive analysis of the carbohydrate composition of food systems. The basis of the primary reference measurement procedure (PRMP) is the method of iodometric titration based on the ability of iodine to oxidize aldosaccharides to the corresponding uronic acids in an alkaline medium. The accuracy of the PRMP was improved by optimizing the measurement parameters, including the method of high-performance liquid chromatography with refractometric detection (HPLC/RD), and by establishing their possible variation limit based on a multifactorial experiment. The application of the PRMP made it possible to measure the mass fraction of carbohydrates (total sugar) as the sum of the mass fractions of reducing and non-reducing sugars in milk and dairy products, grain and milk products, low-lactose and lactose-free products, including those used for preparing baby food. In order to further detail the carbohydrate composition, highly selective methods were developed for measuring the mass fractions of lactose and galactose by the spectrophotometric (enzymatic) method, and the mass fractions of mono- and disaccharides by the HPLC/RD method in milk and dairy products. It was found that the measurement results of both the total content of carbohydrates and individual mono- and disaccharides in the samples of milk and dairy products obtained by various methods (iodometric titration, HPLC/RD, enzymatic method, refractometry, IR spectroscopy, calculation method) are consistent with each other subject to the stated uncertainties. Thus, the applicability of the developed PRMP in combination with other methods for conducting an in-depth analysis of the carbohydrate composition of milk and dairy products was confirmed. The developed procedures were used to characterize reference materials for the composition of dairy products (3 types), mono- and disaccharides (9 types).
- 22 November 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 18 (2) , 35-56
Open AccessDevelopment of Measurement Procedures for the Characterization of Reference Materials for Carbohydrate Composition of Dairy Products
This article studies the development of measurement procedures based on various methods for a comprehensive analysis of the carbohydrate composition of food systems. The basis of the primary reference measurement procedure (PRMP) is the method of iodometric titration based on the ability of iodine to oxidize aldosaccharides to the corresponding uronic acids in an alkaline medium. The accuracy of the PRMP was improved by optimizing the measurement parameters, including the method of high-performance liquid chromatography with refractometric detection (HPLC/RD), and by establishing their possible variation limit based on a multifactorial experiment. The application of the PRMP made it possible to measure the mass fraction of carbohydrates (total sugar) as the sum of the mass fractions of reducing and non-reducing sugars in milk and dairy products, grain and milk products, low-lactose and lactose-free products, including those used for preparing baby food. In order to further detail the carbohydrate composition, highly selective methods were developed for measuring the mass fractions of lactose and galactose by the spectrophotometric (enzymatic) method, and the mass fractions of mono- and disaccharides by the HPLC/RD method in milk and dairy products. It was found that the measurement results of both the total content of carbohydrates and individual mono- and disaccharides in the samples of milk and dairy products obtained by various methods (iodometric titration, HPLC/RD, enzymatic method, refractometry, IR spectroscopy, calculation method) are consistent with each other subject to the stated uncertainties. Thus, the applicability of the developed PRMP in combination with other methods for conducting an in-depth analysis of the carbohydrate composition of milk and dairy products was confirmed. The developed procedures were used to characterize reference materials for the composition of dairy products (3 types), mono- and disaccharides (9 types).