M. P. Krasheninina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
M. P. Krasheninina has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Olga S. Golynets
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
3 shared publications - Anna S. Sergeeva
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
2 shared publications - Olga S. Shokhina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
2 shared publications A. L. Khohlov
Yaroslavl State Medical University
1 shared publicationA. V. Sobina
UNIIM - Affiliated Branch of the D.I. Mendeleev Institute for Metrology
1 shared publication- Alena V. Sobina
UNIIM – Affiliated branch of the D. I. Mendeleyev Institute for Metrology
1 shared publication
Latest Publications
- Open Access
- 8 October 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 22 (3) , 51-67
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine | Shipitsyn | Measurement Standards. Reference Materials Применение метода дифференциальной сканирующей калориметрии для исследования и разработки стандартных образцов температуры фазовых переходов органических веществ на основе бензофенона, бензойной кислоты и кофеина | Шипицын | Эталоны. Стандартные образцы
- 8 October 2026
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 22 (3) , 51-67
Open AccessApplication of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine
Application of Differential Scanning Calorimetry for the Research and Development of Reference Materials for Phase Transition Temperatures of Organic Substances Based on Benzophenone, Benzoic Acid and Caffeine | Shipitsyn | Measurement Standards. Reference Materials Применение метода дифференциальной сканирующей калориметрии для исследования и разработки стандартных образцов температуры фазовых переходов органических веществ на основе бензофенона, бензойной кислоты и кофеина | Шипицын | Эталоны. Стандартные образцы
- Open Access
- 25 December 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 20 (4) , 36-56
Development of Reference Materials of Benzoic and Sorbic Acids
The article introduces the development of reference materials of benzoic and sorbic acids with a certified value of the mass fraction of the main substance. The development of reference materials was carried out in several stages: identification, characterization, study of homogeneity and stability of reference materials. Identification of candidate materials for reference materials was carried out by IR Fourier spectroscopy and determination of melting point by differential thermal analysis. The candidate materials for reference materials were characterized by the indirect method «one hundred minus the sum of impurities» with confirmation of the measurement results by the direct method – the acid-base titration method. It was established that the measurement results of the mass fraction of the main substance of benzoic and sorbic acids obtained by the acid-base titration method and the mass balance method are consistent with each other taking into account the values of expanded uncertainties. The work was carried out using primary and secondary standards. The accuracy of the measurement results of the mass fraction of the main substance was increased by searching for and selecting optimal measurement modes when determining each type of impurity. The homogeneity of materials was determined using the one-way analysis of variance method; stability was determined using the regression analysis method.The developed reference materials of benzoic and sorbic acids were included in the Federal Information Fund for Ensuring the Uniformity of Measurements as GSO 12297–2023 and GSO 12298–2023. The certified value of the mass fraction of the main substance is in the range from 95.00 to 100.00 %, the limits of the permissible values of the absolute error at P = 0.95 are ± 0.5 %.The use of GSO 12297–2023 and GSO 12298–2023 for certification and control of the accuracy of methods, establishment and control of the stability of calibration characteristics of measuring instruments, verification, calibration of measuring instruments can improve the quality of food products, food raw materials and pharmaceuticals.
- 25 December 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 20 (4) , 36-56
Open AccessDevelopment of Reference Materials of Benzoic and Sorbic Acids
The article introduces the development of reference materials of benzoic and sorbic acids with a certified value of the mass fraction of the main substance. The development of reference materials was carried out in several stages: identification, characterization, study of homogeneity and stability of reference materials. Identification of candidate materials for reference materials was carried out by IR Fourier spectroscopy and determination of melting point by differential thermal analysis. The candidate materials for reference materials were characterized by the indirect method «one hundred minus the sum of impurities» with confirmation of the measurement results by the direct method – the acid-base titration method. It was established that the measurement results of the mass fraction of the main substance of benzoic and sorbic acids obtained by the acid-base titration method and the mass balance method are consistent with each other taking into account the values of expanded uncertainties. The work was carried out using primary and secondary standards. The accuracy of the measurement results of the mass fraction of the main substance was increased by searching for and selecting optimal measurement modes when determining each type of impurity. The homogeneity of materials was determined using the one-way analysis of variance method; stability was determined using the regression analysis method.The developed reference materials of benzoic and sorbic acids were included in the Federal Information Fund for Ensuring the Uniformity of Measurements as GSO 12297–2023 and GSO 12298–2023. The certified value of the mass fraction of the main substance is in the range from 95.00 to 100.00 %, the limits of the permissible values of the absolute error at P = 0.95 are ± 0.5 %.The use of GSO 12297–2023 and GSO 12298–2023 for certification and control of the accuracy of methods, establishment and control of the stability of calibration characteristics of measuring instruments, verification, calibration of measuring instruments can improve the quality of food products, food raw materials and pharmaceuticals.
- Open Access
- 7 January 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (5) , 95-112
Methodology for Measuring Volume Fractions of Gases Using Gas Chromatography in Medical Nitrous Oxide: Features of Assessing Metrological Characteristics
An analysis by the Federal Information Fund revealed the lack of methods for measuring the volume fractions of nitrous oxide, carbon oxide and dioxide, oxygen, nitrogen, and non-condensable gases in medical nitrous oxide using portable devices. Nitrous oxide is widely used in medicine, and therefore this research was committed to the development and certification of a method for measuring volume fractions of nitrous oxide, carbon oxide and dioxide, oxygen, nitrogen, and non-condensable gases using gas chromatography in medical nitrous oxide. Certification of the measurement method in accordance with legal requirements in the field of ensuring the uniformity of measurements was carried out by organizing a quasi-interlaboratory experiment; the following approaches were used to obtain the measurement result: the method for constructing a calibration dependence, the external standard method, and the calculation method. In addition, the study presents an algorithm and results for calculating the uncertainty of measurements of volume fractions of gases, subject to the provisions of EURACHEM CITAC, as well methodologically influencing factors that were assessed using a multifactorial experiment and its processing by regression analysis.
- 7 January 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (5) , 95-112
Open AccessMethodology for Measuring Volume Fractions of Gases Using Gas Chromatography in Medical Nitrous Oxide: Features of Assessing Metrological Characteristics
An analysis by the Federal Information Fund revealed the lack of methods for measuring the volume fractions of nitrous oxide, carbon oxide and dioxide, oxygen, nitrogen, and non-condensable gases in medical nitrous oxide using portable devices. Nitrous oxide is widely used in medicine, and therefore this research was committed to the development and certification of a method for measuring volume fractions of nitrous oxide, carbon oxide and dioxide, oxygen, nitrogen, and non-condensable gases using gas chromatography in medical nitrous oxide. Certification of the measurement method in accordance with legal requirements in the field of ensuring the uniformity of measurements was carried out by organizing a quasi-interlaboratory experiment; the following approaches were used to obtain the measurement result: the method for constructing a calibration dependence, the external standard method, and the calculation method. In addition, the study presents an algorithm and results for calculating the uncertainty of measurements of volume fractions of gases, subject to the provisions of EURACHEM CITAC, as well methodologically influencing factors that were assessed using a multifactorial experiment and its processing by regression analysis.
- Open Access
- 7 January 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (5) , 127-141
Method for Measuring the Mass Fraction of Soybean Trypsin Inhibitor: Features of Development and Certification
Modern industrialization increases the requirements for the accuracy of identifying allergens, especially those that have a negative impact – soy trypsin inhibitor (STI). Correct determination of the presence of STI in food products containing soybeans is key for product safety control and labeling. The authors set a goal to develop and certify a method for measuring the mass fraction of STI using an enzyme-linked immunosorbent assay – a technique that may increase the specificity of the method and avoid false-negative results. The object of research was a method for analyzing food allergens – an enzyme-linked immunosorbent assay carried out with a set of reagents produced by XEMA LLC. In the process of developing the measurement method, the main methodological factors influencing the accuracy of the measurement results were optimized: sample weight, time of its extraction, time and speed of sample centrifugation, ratio of supernatant liquid to ELISA buffer, incubation temperature, interaction time of the allergen-antibody complex with the coloring agent, the wavelength for measuring absorbance, and the maximum time for measuring absorbance after introduction of the stop reagent. The developed method was tested during an interlaboratory experiment with the participation of 5 laboratories. Metrological characteristics were established in accordance with RMG 61–2010. The proposed method was certified in accordance with the requirements of GOST R8.563-2009, No. 102–FZ. The method has a wide range of quantitative determination of the mass fraction of STI from 0.5 to 25.0 μg/kg (ppb) with a detection limit of 0.1 μg/kg (ppb) and a relative error of 40 %. Based on the results of the research, the Federal Information Fund for Ensuring the Uniformity of Measurements (FIF) registered a certified method for identifying and quantifying the content of non-infectious food allergens of plant protein origin in samples of all types of food products and objects related to the requirements for food products, swabs taken from working surfaces during production control using reagent kits for an enzyme-linked immunosorbent assay produced by XEMA LLC No. FR.1.31.2022.43884. The method is intended for use in testing laboratories involved in monitoring the quality and safety of manufactured products; it can be used to confirm product compliance with the mandatory requirements established in the Technical Regulations of the Customs Union TR CU022/2012.
- 7 January 2024
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 19 (5) , 127-141
Open AccessMethod for Measuring the Mass Fraction of Soybean Trypsin Inhibitor: Features of Development and Certification
Modern industrialization increases the requirements for the accuracy of identifying allergens, especially those that have a negative impact – soy trypsin inhibitor (STI). Correct determination of the presence of STI in food products containing soybeans is key for product safety control and labeling. The authors set a goal to develop and certify a method for measuring the mass fraction of STI using an enzyme-linked immunosorbent assay – a technique that may increase the specificity of the method and avoid false-negative results. The object of research was a method for analyzing food allergens – an enzyme-linked immunosorbent assay carried out with a set of reagents produced by XEMA LLC. In the process of developing the measurement method, the main methodological factors influencing the accuracy of the measurement results were optimized: sample weight, time of its extraction, time and speed of sample centrifugation, ratio of supernatant liquid to ELISA buffer, incubation temperature, interaction time of the allergen-antibody complex with the coloring agent, the wavelength for measuring absorbance, and the maximum time for measuring absorbance after introduction of the stop reagent. The developed method was tested during an interlaboratory experiment with the participation of 5 laboratories. Metrological characteristics were established in accordance with RMG 61–2010. The proposed method was certified in accordance with the requirements of GOST R8.563-2009, No. 102–FZ. The method has a wide range of quantitative determination of the mass fraction of STI from 0.5 to 25.0 μg/kg (ppb) with a detection limit of 0.1 μg/kg (ppb) and a relative error of 40 %. Based on the results of the research, the Federal Information Fund for Ensuring the Uniformity of Measurements (FIF) registered a certified method for identifying and quantifying the content of non-infectious food allergens of plant protein origin in samples of all types of food products and objects related to the requirements for food products, swabs taken from working surfaces during production control using reagent kits for an enzyme-linked immunosorbent assay produced by XEMA LLC No. FR.1.31.2022.43884. The method is intended for use in testing laboratories involved in monitoring the quality and safety of manufactured products; it can be used to confirm product compliance with the mandatory requirements established in the Technical Regulations of the Customs Union TR CU022/2012.
- Open Access
- 17 January 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 17 (4) , 65-84-84
Application of direct and indirect methods for determining the mass fraction of the main component in flotation potassium chloride
The article is devoted to the comparison of two approaches to determining the purity of metal salts on the example of a complex in composition object - flotation potassium chloride. The results of determining the mass fraction of the main component (potassium chloride) in flotation potassium chloride obtained by direct (using the coulometric titration method with correction for anions titrated with the determined chloride ion and an excess of cations) and indirect (according to the scheme 100% minus the amount of impurities with regard to their species) methods. It is shown that direct and indirect methods give well consistent results: (96.08 ± 0.17) % and (96.11 ± 0.12) %, respectively. Also, the measurement results obtained using the standard installations considering the uncertainty are well consistent with the certified value of the mass fraction of potassium chloride (96.11 ± 0.11) %, obtained based on an interlaboratory experiment in laboratories that perform measurements in accordance with GOST 20851.3. The feature of the direct and indirect methods implemented in this work is the construction of a model of the chemical composition of the analysed object based on a priori and experimental data using two basic principles when summing up the content of impurities: the conditions of material balance and the principle of electroneutrality.
- 17 January 2022
- Published by Ural Research Institute of Metrology (UNIIM) in Measurement Standards. Reference Materials
- Vol. 17 (4) , 65-84-84
Open AccessApplication of direct and indirect methods for determining the mass fraction of the main component in flotation potassium chloride
The article is devoted to the comparison of two approaches to determining the purity of metal salts on the example of a complex in composition object - flotation potassium chloride. The results of determining the mass fraction of the main component (potassium chloride) in flotation potassium chloride obtained by direct (using the coulometric titration method with correction for anions titrated with the determined chloride ion and an excess of cations) and indirect (according to the scheme 100% minus the amount of impurities with regard to their species) methods. It is shown that direct and indirect methods give well consistent results: (96.08 ± 0.17) % and (96.11 ± 0.12) %, respectively. Also, the measurement results obtained using the standard installations considering the uncertainty are well consistent with the certified value of the mass fraction of potassium chloride (96.11 ± 0.11) %, obtained based on an interlaboratory experiment in laboratories that perform measurements in accordance with GOST 20851.3. The feature of the direct and indirect methods implemented in this work is the construction of a model of the chemical composition of the analysed object based on a priori and experimental data using two basic principles when summing up the content of impurities: the conditions of material balance and the principle of electroneutrality.
- 31 March 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (3) , 378-383
Determination of the Antioxidant Capacity of Pharmaceuticals by Potentiometry: Indicators of Measurement Accuracy
The antioxidant capacity (AOC) of water–alcohol tinctures of medicinal plant materials, vitamins, and vitamin complexes was investigated. The accuracy indicators for determining the antioxidant capacity of these samples are found; the accuracy of the measurement results is examined using a sample of ascorbic acid with a known concentration of the main component. The relative measurement error of the antioxidant capacity of herbal and synthetic medications does not exceed 10%.
- 31 March 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (3) , 378-383
Determination of the Antioxidant Capacity of Pharmaceuticals by Potentiometry: Indicators of Measurement Accuracy
The antioxidant capacity (AOC) of water–alcohol tinctures of medicinal plant materials, vitamins, and vitamin complexes was investigated. The accuracy indicators for determining the antioxidant capacity of these samples are found; the accuracy of the measurement results is examined using a sample of ascorbic acid with a known concentration of the main component. The relative measurement error of the antioxidant capacity of herbal and synthetic medications does not exceed 10%.