HXHongjian Xia

Hongjian Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongjian Xia has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Capacitor Parameter Estimation Based on Wavelet Transform and Convolution Neural Network

    by Hongjian Xia, Yi Zhang, Minyou Chen, Dan Luo, Wei Lai, Huai Wang

    This article proposes a capacitor parameter estimation method based on wavelet transform and convolution neural network (CNN). By fully utilizing wavelet transforms and the inherently nonideal properties of bandpass filters, the low-frequency and midfrequency band features contained in capacitor voltages are extracted with high resolution. Leveraging these features, a subsequent CNN network simultaneously estimates two crucial aging indicators of capacitors, i.e., capacitance and equivalent series resistance (ESR). While most existing methods can only identify either capacitance or ESR, the proposed method stands out by addressing both. The integration of two different frequency features enables the proposed method to exhibit broader applicability across different modulation schemes and control strategies, and is less sensitive to load conditions and sampling frequency. Experiment results based on a modular multilevel converter case study prove the effectiveness of the proposed method.


  • Time-Varying Cumulative Damage Recursive Method for Power Semiconductor Devices

    by Wei Lai, Hanrui Li, Hui Li, Minyou Chen, Ran Yao, Hongjian Xia, Renkuai Liu, Anbin Liu

    Accurate simulation of power semiconductor devices failure process is one of the most important means to clarify the failure mechanism and evaluate the device reliability, which is induced by the associated internal temperature gradient acting on the mismatch of coefficients of thermal expansion between adjacent layers and internal temperature gradients. This article investigates the microstructure change of the new and replaced modules using the CT scanner, which represents that the void distribution of the die-attach solder layer is an important factor to indicate the reliability status of the power semiconductor devices. A multiple physical field model combining time-varying cumulative damage recursive method is proposed to simulate the damage accumulation and the physical failure process based on mesh automatic updated method and material failure formula. The number of cycles to failure, thermal resistance, and junction temperature extracted from power cycling test results are used to validate the accuracy of the parameter variation. The physical outline of the voids is extracted to prove the consistency of the microstructure change. This method is intended for operational management and also provided the foundation for the design and development of power electronic devices with high power and high reliability.


  • Capacitor Condition Monitoring for Modular Multilevel Converter Based on Charging Transient Voltage Analysis

    by Hongjian Xia, Yi Zhang, Minyou Chen, Wei Lai, Dan Luo, Huai Wang

    This article proposes a capacitor condition monitoring (CM) method for modular multilevel converter (MMC) in motor drive applications. The proposed method is based on wavelet decomposition of transient voltage signals, which is independent of modulation schemes and control strategies. The equivalent series resistance (ESR) change can be detected with a moderate computation requirement. Both simulation and experimental results have verified the performance of the proposed method.


  • Open Access

    A Fault Detection Method of IGBT Bond Wire Fatigue Based on the Reduction of Measured Heatsink Thermal Resistance

    by Dan Luo, Minyou Chen, Wei Lai, Hongjian Xia, Zhenyu Deng, Zhi Wang, Kai Yu

    Bond wire lift-off is one of the major failure mechanisms in the insulated gate bipolar transistor (IGBT) modules. Detecting the fault of bond wires is important to avoid the open-circuit fault of IGBT to ensure the reliable operation of power converters. In this paper, we propose a novel bond wire fatigue detection method for IGBT, which could be used in normal working conditions. Firstly, we investigated the dependence of bond wire fatigue on heatsink thermal resistance. An aging rate K was proposed to compare the measured thermal resistance with the initial value, which could indicate the bond wire fatigue. Then, this proposed method was verified by simulation and experimental results under different current levels. Finally, a power cycling test was used to show the aging process of the IGBT module, which shows the feasibility of proposed method.


  • Open Access

    A Study on the Effect of Bond Wires Lift-Off on IGBT Thermal Resistance Measurement

    by Dan Luo, Minyou Chen, Wei Lai, Hongjian Xia, Xueni Ding, Zhenyu Deng

    Bond wire lift-off will cause an increase of remaining wires’ power dissipation, which usually is ignored for healthy modules. However, only partial wires’ power dissipation transfers through thermal path from junction to case, which will lead to overestimate the whole power dissipation from collector to emitter pole and underestimate the calculated thermal resistance using the proportion of temperature difference to power dissipation. A FEM model is established to show the change of heat flow after bond wires were removed, the temperature of bond wires increases, and the measured thermal resistance decrease after bond wires lift-off. It is validated by experimental results using open package Insulated Gate Bipolar Transistor (IGBT) modules under different current conditions. This conclusion might be helpful to indicate the bond wires lift-off and solder fatigue by comparing the change of measured thermal resistance. Using the Kelvin setup to measure thermal resistance will cause misjudgment of failure mode due to the ignoring of wires’ power dissipation. This paper proposed that the lift-off of bond wires will lead to underestimating the thermal resistance measurement, which will overestimate the lifetime of IGBT module and misjudge its state of health.