XCXinchao Cui

Xinchao Cui

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinchao Cui has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetization Dynamics-Modulated Near-Infrared Mie Scattering Enables Homogeneous Femtomolar Immunosensing for Whole Blood

    by Yulin Yang, Qin Bi, Ke Qin, Guang Jia, Qian Gao, Bing Tan, Yanfang Wu, Xinchao Cui, Jing Zhong, Wenzhong Liu, et al.

    Low-abundance biomarkers in whole blood hold immense clinical value for disease diagnosis. However, their detection remains constrained by the difficulty of conventional assays in simultaneously achieving high sensitivity, rapid turnaround, and operational simplicity. Here we introduce optomagnetic particle spectroscopy (OptoMPS), a homogeneous biosensing technology for magnetic label-based immuno-agglutination assays, which overcomes these limitations via the integration of nonlinear magnetization dynamics and orientation-dependent Mie scattering of magnetic particles. Under an optimally biased oscillating magnetic field, numerical simulations indicate that third-harmonic optical modulation can be markedly amplified by the combined effects of hydrodynamic size expansion, effective magnetic moment reduction, and Mie scattering, yielding substantial signal contrast between agglutinated and monomeric magnetic particles under idealized monomer–dimer conditions. Using near-infrared excitation and magnetic actuation to suppress biological matrix background, the platform achieves a detection limit of 63 fM (1.54 pg/mL) for cardiac troponin I (cTnI) in 10% (v/v) routine whole blood within 5 min. Sample pretreatment is required only for severely lipemic specimens. Preliminary method comparison using 58 clinical samples shows good agreement with the commercial chemiluminescence immunoassay used in routine clinical practice, with good capacity to distinguish cTnI-positive and cTnI-negative samples classified by the reference method. These results demonstrate that OptoMPS is an effective platform for femtomolar biomarker detection in complex biological matrices.

  • Remote non-invasive nanothermometry based on opto-magnetic detection

    by Xinchao Cui, Joanna Chwiej, Ryszard Buczyński, Bo Tian, Wenzhong Liu

    As an emerging sensing paradigm for magnetic nanoparticles (MNPs), opto-magnetic detection offers distinct advantages over conventional magnetic methods, including remote operation and non-invasiveness. Optical readout enables stable monitoring of the dynamic response of MNPs under magnetic excitation and has recently shown promise for rapid biomolecular detection. The core principle of opto-magnetic detection is the magnetic-field-induced modulation of the extinction cross section of MNPs, thereby transducing physicochemical information from the local particle environment via the dynamic characteristics of Brownian relaxation. In this work, we adopt the Cole–Cole model to effectively describe the thermal motion of particles arising from the interplay between magnetic potential energy and thermal energy. Furthermore, exploiting the relationship between the second harmonic phase and the Brownian relaxation-time spectrum, we propose an opto-magnetic thermometry method. By employing a Cole–Cole-derived Cauchy-type relaxation-time distribution, we achieve high-precision temperature measurements over the range of 308–318 K, with a root mean square error of only 0.03 K. This approach provides technical support for opto-magnetic thermometry in applications such as intracellular temperature imaging, real-time thermotherapy monitoring, and point-of-care testing.

  • Optomagnetic Viscometry for Monitoring Nanoscale Blood Coagulation Dynamics In Vitro

    by Qin Bi, Yulin Yang, Liyang Shi, Xinli Liu, Zheyuan Zhou, Zhuxin Dong, Wenzhong Liu, Xinchao Cui, Bing Tan, Bo Tian

    Capturing the dynamic variations of nanoscale viscosity within biological fluids is pivotal for deciphering the mechanisms of critical physiological and pathological processes, notably blood coagulation. However, this endeavor remains challenging due to the limitations of conventional techniques. Standard assays relying on bulk optical or rheological measurements lack the spatial resolution required for nanoscale viscosity analysis, failing to distinguish cascade processes in complex coagulation reactions. We present an optomagnetic nanorelaxometry platform that probes nanoscale viscosity in real time through analysis of magnetic nanoparticles’ Brownian relaxation dynamics. Requiring a sample volume of 50 μL, the platform demonstrated quantitative accuracy in glycerol solutions and successfully tracked dynamic viscosity changes during collagen gelation. Most notably, during platelet-rich plasma coagulation, our platform revealed a nonmonotonic viscosity profile inaccessible to conventional assays, suggesting a novel methodological perspective on coagulation mechanisms. Evaluation with clinical anticoagulants and a thrombolytic agent further confirmed its practical utility, underscoring the platform’s potential for pharmacological screening and point-of-care coagulation monitoring with nanoscale resolution.


  • Magnetic particle optical imaging method based on magnetic linear dichroism effect

    by Xinchao Cui, Joanna Chwiej, Ryszard Buczyński, Wenzhong Liu

    Magnetic particle imaging (MPI) has attracted considerable attention in recent years because it can achieve functional imaging of magnetic nanoparticles (MNPs) within biological tissues. Developing efficient MPI techniques while simultaneously enhancing imaging resolution is crucial for advancing their clinical applications. In this Letter, we propose a magnetic particle optical imaging (MPOI) method capable of quantitatively mapping the two-dimensional spatial distribution of (MNPs). This approach leverages optical imaging technology to simplify both the construction of the free-field region and the complex image reconstruction process. By extracting the second harmonic signal through phase-sensitive detection, the signal-to-noise ratio of the magnetic linear dichroism image is improved to 60 dB. The proposed method achieves highly sensitive detection of MNPs at concentrations as low as 0.01 mg/ml, along with 50 µm two-dimensional spatial resolution. These results demonstrate that the MPOI method provides a powerful platform for employing magnetic nanoparticles as magnetic labels in the metabolic imaging of living cells.

  • A Remote Noninvasive Thermometer Based on Faraday Rotation of Magnetic Nanoparticles

    by Xinchao Cui, Chong Lu, Chunping Liu, Ryszard Buczyński, Wenzhong Liu

    Magnetic nanoparticles (MNPs) are temperature sensitive, making them useful as probes for measuring cellular temperature. In this paper, we propose a remote non-invasive thermometer that replaces a traditional magnetic sensor with linearly polarized light as the transmission medium, utilizing the Faraday rotation of MNPs. This method not only overcomes the limitations of distance on temperature measurement accuracy but also offers strong anti-interference capabilities. Using this thermometer, we measured the cooling process of MNPs within a temperature range of 310–316 K, achieving an estimated temperature root mean square error (RMSE) of 0.14 K. This approach shows promise for integration with microscopy systems for temperature imaging of cells or biological tissues, potentially revealing new biological insights.


  • Mie scattering in magnetic nanoparticle agglutination-based optomagnetic biosensing

    by Yulin Yang, Jiajun Cui, Xinchao Cui, Wenzhong Liu, Bo Tian, Jing Zhong

    Magnetic nanoparticle (MNP) agglutination-based optomagnetic biosensing has been applied for rapid and sensitive detection of various biomolecules. However, the underlying physics of optomagnetic biosensing remains a hurdle, especially when the size of MNPs approaches the laser wavelength, i.e., the scattering enters the Mie regime. In this study, we propose a numerical model by combining the Fokker–Planck equation and the T-matrix to explain the effect of Mie scattering on the optomagnetic signal of the agglutinated MNPs. It indicates that the orientation-dependent Mie scattering of the MNP dimer leads to an inverse optomagnetic response compared to that of the MNP monomer. The inverse optomagnetic response can dominate with the enhancement of Mie scattering. To verify the numerical model, biotinylated bovine serum albumin (biotin-BSA) is applied to agglomerate streptavidin-coated MNPs in a standard biosensing strategy representing the immuno-agglutination assay. Guided by the model, a proportion-based signal analysis is proposed to improve the performance of the MNP agglutination-based optomagnetic biosensor, which provides a picomolar detection limit for biotin-BSA (∼0.1 ng/mL) with a total assay time of 8 min, paving the way for more accurate point-of-care diagnosis.


  • Rapid and High Sensitivity Temperature Measurement Based on Near-Extinction Photoelastic Modulated Magneto-Optical Kerr Effect of Fe-Gd Nanofilm

    by Lan Li, Wentong Yi, Xinchao Cui, Wenzhong Liu

    In this study, we demonstrate a novel magneto-optical thermometer using a Magneto-optical Kerr Effect (MOKE) system optimally configured with a photoelastic modulator (PEM) that combines the optical and pyro effects of Fe-Gd nanofilm to detect transient surface temperatures with high sensitivity and temporal resolution. The AC-DC harmonic ratio of the modulating frequency senses the temperature-induced Kerr signal of the metal film. In previous MOKE systems using a PEM, the optical axis of the analyzer was configured at 45° to maximize the harmonic amplitude. However, the decreased sensitivity of the harmonic ratio in this conventional configuration leads to lower signal-to-noise ratios (SNRs). By configuring the analyzer axis at a near-extinction position close to 0°, the signal gain of the harmonic ratio can be increased, thus significantly improving the SNRs of the temperature measurement. Experimental results based on near-extinction photoelastic modulated MOKE (NEPEM MOKE) of Fe-Gd nanofilm show that the harmonic ratio achieves a resolution better than 0.02 K over a wide range, from room temperature to the Curie temperature of Fe-Gd nanofilm. On this basis, the magneto-optical thermometer can capture thermal pulses with a pulse width of no less than 80 μs. The proposed method combines the high spatial and temporal resolution of the MOKE, which converts temperature changes into magneto-optical signal changes. Therefore, this noninvasive magneto-optical thermometer provides a possible method for temperature measurements on the micro- and nanometer scales.

  • A Rapid and Sensitive Magnetic Immunoassay of Biomolecules Based on Magnetic Nanoparticles

    by Xinchao Cui, Lan Li, Wenzhong Liu

    In this study, a real-time detection method for amol biomolecules based on 2nd and 3rd harmonics of water-based magnetic nanoparticles (MNPs) is reported. In previous magnetic immunoassay methods based on magnetic particle spectroscopy (MPS), the 1st harmonic was affected by the diamagnetic environment and would easily interfere with the signal at a concentration lower than pM MNPs. We propose to use the ratio of the 3rd to 2nd harmonics to achieve more sensitive immune detection by using an AC plus DC excitation magnetic field. We found that a homemade magnetic particle spectrometer can ensure that the signal-to-noise ratios of the 2nd and 3rd harmonics are roughly the same by modulating the DC magnetic field to compare and adjust the amplitudes of the 2nd and 3rd harmonics. The immunoassay sensitivity was greatly improved, and the ability of magnetic immunoassay based on water-based MNPs to detect trace biomolecules was roughly estimated using the limit of detection (LOD) for 0.4 pM (40 amol) biomolecules in a 100 μL suspension, by binding streptavidin to biotin. In addition, the entire test is completed within 1 s, which will be useful in testing for viral aerosols in the air.