Yanhua Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanhua Peng has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Donglin Su
Beihang University
4 shared publications - Hui Xu
School of Electronic and Information Engineering, Beihang University, Beijing, China
2 shared publications - Lingnan Song
School of Electronics and Information Engineering, Beihang University, Beijing, China
2 shared publications - Shuo Cui
School of Electronic and Information Engineering, Beihang University, Beijing, China
2 shared publications - Dongdong Shen
School of Electronic and Information Engineering and the Research Institute of Frontier Science and Technology Innovation, Beihang University, Beijing, China
1 shared publication - Hangyi Zhou
School of Electronic and Information Engineering and the Research Institute of Frontier Science and Technology Innovation, Beihang University, Beijing, China
1 shared publication
Latest Publications
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (18) , 35255-35267
Conformal and Distributed Monitoring of Electromagnetic Emission Enabled by RFID Backscattering and Colorimetric Visualization
Distributed monitoring of electromagnetic radiation has emerged as a critical challenge in modern wireless environments. To address this need, we present a radio frequency identification (RFID)-integrated electromagnetic field detection system that enables rapid and distributed collection of electromagnetic field intensity across the 2.2–6-GHz spectrum. The system achieves a dynamic range of 0.05–60 V/m for electric field monitoring while providing instantaneous visual feedback through colorimetric indicators. Validated for stable operation at bending radii exceeding 30 mm, our solution combines miniaturization, low-power operation, and mechanical flexibility to support scalable multinode deployments. We demonstrate this capability through a 16-element multinode prototype that simultaneously displays field intensities across distributed locations while enabling accurate RFID-based data acquisition. The system was further deployed in an automobile-manufacturing industrial scenario with 11 distributed sensing nodes, which successfully indicate potential interference sources in space and provide both immediate visual alerts and quantifiable data. The proposed sensing paradigm provides an optimized solution for spatially resolved field monitoring in industrial facilities and healthcare environments, where dense deployments of low-profile sensors are desirable for rapid identification of interference sources or mapping of overexposure zones around vulnerable populations.
- 4 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (18) , 35255-35267
Conformal and Distributed Monitoring of Electromagnetic Emission Enabled by RFID Backscattering and Colorimetric Visualization
Distributed monitoring of electromagnetic radiation has emerged as a critical challenge in modern wireless environments. To address this need, we present a radio frequency identification (RFID)-integrated electromagnetic field detection system that enables rapid and distributed collection of electromagnetic field intensity across the 2.2–6-GHz spectrum. The system achieves a dynamic range of 0.05–60 V/m for electric field monitoring while providing instantaneous visual feedback through colorimetric indicators. Validated for stable operation at bending radii exceeding 30 mm, our solution combines miniaturization, low-power operation, and mechanical flexibility to support scalable multinode deployments. We demonstrate this capability through a 16-element multinode prototype that simultaneously displays field intensities across distributed locations while enabling accurate RFID-based data acquisition. The system was further deployed in an automobile-manufacturing industrial scenario with 11 distributed sensing nodes, which successfully indicate potential interference sources in space and provide both immediate visual alerts and quantifiable data. The proposed sensing paradigm provides an optimized solution for spatially resolved field monitoring in industrial facilities and healthcare environments, where dense deployments of low-profile sensors are desirable for rapid identification of interference sources or mapping of overexposure zones around vulnerable populations.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (12) , 4283-4287
An Integrated Signal Injection and Detection Broadband Near-Field Probe for Circuit Characterization
In this letter, a probe with integrated signal injection and detection is designed. By actively injecting signals into the circuit, the probe enables the identification of characteristics at different locations of the circuit. The probe features a minimum width of 4 mm, and a length of 59.32 mm. By using L-shaped structures and impedance matching techniques, the probe achieves a frequency range of 40 GHz. Additionally, the design incorporates a ground-signal-ground-signal-ground structure to ensure high isolation between the injection and detection components. Near field scanning of the microstrip line enables the realization of S-parameter and phase distributions at various frequencies, facilitating the extraction of circuit characteristics at different spatial locations.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (12) , 4283-4287
An Integrated Signal Injection and Detection Broadband Near-Field Probe for Circuit Characterization
In this letter, a probe with integrated signal injection and detection is designed. By actively injecting signals into the circuit, the probe enables the identification of characteristics at different locations of the circuit. The probe features a minimum width of 4 mm, and a length of 59.32 mm. By using L-shaped structures and impedance matching techniques, the probe achieves a frequency range of 40 GHz. Additionally, the design incorporates a ground-signal-ground-signal-ground structure to ensure high isolation between the injection and detection components. Near field scanning of the microstrip line enables the realization of S-parameter and phase distributions at various frequencies, facilitating the extraction of circuit characteristics at different spatial locations.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High Accuracy Near-Field Electromagnetic Emission Identification System Using Characteristics Recognition and Image Localization
In this paper, an automatic near-field measurement system is introduced to record the electromagnetic emission (EME) of equipment under testing (EUT). Firstly, a camera is used to capture the measurement area, which is combined with an image positioning method to achieve fast and accurate positioning of the area. Then, based on the wavelet transform and autocorrelation transform of the EME signal identification algorithm, the system further identifies the broadband and narrowband characteristics of the signal and obtains the power distributions of the corresponding characteristics. In performance tests, the near-field probe moves with a minimum stepping accuracy of 0.1 mm. The movement error of the consistency and stability are guaranteed as less than 1% of the set value. The image positioning error in the 30 cm × 30 cm scanned area is less than 0.5 mm. Finally, the system identifies EME signals from a circuit with multiple crystal oscillators and a sine signal, predictive identification of the circuit functions under the metal shell of a router system. The proposed measurement system therefore offers great measurement accuracy, stability, and efficiency.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High Accuracy Near-Field Electromagnetic Emission Identification System Using Characteristics Recognition and Image Localization
In this paper, an automatic near-field measurement system is introduced to record the electromagnetic emission (EME) of equipment under testing (EUT). Firstly, a camera is used to capture the measurement area, which is combined with an image positioning method to achieve fast and accurate positioning of the area. Then, based on the wavelet transform and autocorrelation transform of the EME signal identification algorithm, the system further identifies the broadband and narrowband characteristics of the signal and obtains the power distributions of the corresponding characteristics. In performance tests, the near-field probe moves with a minimum stepping accuracy of 0.1 mm. The movement error of the consistency and stability are guaranteed as less than 1% of the set value. The image positioning error in the 30 cm × 30 cm scanned area is less than 0.5 mm. Finally, the system identifies EME signals from a circuit with multiple crystal oscillators and a sine signal, predictive identification of the circuit functions under the metal shell of a router system. The proposed measurement system therefore offers great measurement accuracy, stability, and efficiency.
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Broadband Time-Domain Detection System for Electromagnetic Compatibility Conducted Susceptibility Test
In this paper, a novel conducted susceptibility (CS) test system is proposed to analyze broadband interference for equipment under test (EUT). This system can quickly locate the susceptibility frequency bands and effectively find the susceptibility thresholds. The system can generate a unipolar or bipolar Gaussian pulse signal with a pulse width of less than 720 ps to perform these functions. In addition, the pulse amplitude can be adjusted from ±50 V to ±1.5 kV under a 50 Ω resistance load. The repetition frequency is adjustable within the range of 1 Hz to 1 kHz. The pulse spacing of the bipolar Gaussian pulse signal can be controlled from 0.25 ns to 12 ns in the step of 0.25 ns. In detail, a CS test on an electric vehicle was performed with the proposed system and an existing CS system. By using the proposed system, three potential problems of electric vehicles were predicted, susceptible frequency bands were located, and susceptibility thresholds were determined. The proposed method has high test efficiency and high reliability.
- 1 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Broadband Time-Domain Detection System for Electromagnetic Compatibility Conducted Susceptibility Test
In this paper, a novel conducted susceptibility (CS) test system is proposed to analyze broadband interference for equipment under test (EUT). This system can quickly locate the susceptibility frequency bands and effectively find the susceptibility thresholds. The system can generate a unipolar or bipolar Gaussian pulse signal with a pulse width of less than 720 ps to perform these functions. In addition, the pulse amplitude can be adjusted from ±50 V to ±1.5 kV under a 50 Ω resistance load. The repetition frequency is adjustable within the range of 1 Hz to 1 kHz. The pulse spacing of the bipolar Gaussian pulse signal can be controlled from 0.25 ns to 12 ns in the step of 0.25 ns. In detail, a CS test on an electric vehicle was performed with the proposed system and an existing CS system. By using the proposed system, three potential problems of electric vehicles were predicted, susceptible frequency bands were located, and susceptibility thresholds were determined. The proposed method has high test efficiency and high reliability.