Hui Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Xu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Donglin Su
Beihang University
6 shared publications - Guangzhi Chen
Beihang University
2 shared publications - Jingxuan Chen
School of Electronic and Information Engineering, Beihang University, Beijing, China
2 shared publications - Lingnan Song
School of Electronics and Information Engineering, Beihang University, Beijing, China
2 shared publications - Yanhua Peng
School of Electronic Information Engineering, Beihang University, Beijing, China
2 shared publications - Zhiyu Jia
School of Electronic and Information Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
The Measurement of Dual-Tone Electromagnetic Susceptibility for Integrated Circuits: Characteristics Analysis and Threshold Prediction
As electromagnetic interference (EMI) becomes increasingly complex, conventional continuous wave (CW)-based direct power injection (DPI) tests face challenges in accurately characterizing the electromagnetic susceptibility (EMS) of integrated circuits (ICs). This article focuses on EMS characterization and threshold prediction under dual-tone EMI, which is essential for ensuring reliable IC operation under complex EMI waveforms. An amplitude modulation (AM)-based test method is proposed to identify the EMS characteristics of various ICs. Dual-tone EMS thresholds are defined, and a corresponding prediction method is proposed for ICs with both average power EMS (A-EMS) and peak power EMS (P-EMS) characteristics. The proposed AM-based test method is validated on three types of digital ICs and three types of analog ICs. Results based on the six types of tested ICs indicate that the analog ICs exhibit A-EMS characteristics, while the digital ICs exhibit P-EMS characteristics across most frequency bands. The proposed prediction method is further evaluated through dual-tone sweeping, which achieves an average prediction error of 0.96 dB across the six tested ICs. The proposed methods provide reliable EMS characterization and accurate threshold prediction under dual-tone EMI conditions.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
The Measurement of Dual-Tone Electromagnetic Susceptibility for Integrated Circuits: Characteristics Analysis and Threshold Prediction
As electromagnetic interference (EMI) becomes increasingly complex, conventional continuous wave (CW)-based direct power injection (DPI) tests face challenges in accurately characterizing the electromagnetic susceptibility (EMS) of integrated circuits (ICs). This article focuses on EMS characterization and threshold prediction under dual-tone EMI, which is essential for ensuring reliable IC operation under complex EMI waveforms. An amplitude modulation (AM)-based test method is proposed to identify the EMS characteristics of various ICs. Dual-tone EMS thresholds are defined, and a corresponding prediction method is proposed for ICs with both average power EMS (A-EMS) and peak power EMS (P-EMS) characteristics. The proposed AM-based test method is validated on three types of digital ICs and three types of analog ICs. Results based on the six types of tested ICs indicate that the analog ICs exhibit A-EMS characteristics, while the digital ICs exhibit P-EMS characteristics across most frequency bands. The proposed prediction method is further evaluated through dual-tone sweeping, which achieves an average prediction error of 0.96 dB across the six tested ICs. The proposed methods provide reliable EMS characterization and accurate threshold prediction under dual-tone EMI conditions.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
A Self-Check Method for Enhancing the Measurement Accuracy of Analog Sensors Under Electromagnetic Interference
Inaccurate measurements of analog sensors caused by electromagnetic interference (EMI) signals threaten the security and reliability of sensor-based systems. This article proposes a self-check method for recognizing and correcting disturbed measurements of analog sensors under EMI signals. The core basis of this method involves the use of a dummy sensing element to make the sensor sensitive only to EMI signals, rather than the measurand. This configuration enables the sensor to switch between normal mode and self-check mode through switching devices. Then the sensor response to EMI signals in normal mode is characterized by that in self-check mode, which is computable. A detailed implementation framework is derived to ensure that the sensor responses to EMI signals in both modes are highly similar, involving the properties of the dummy sensing element, the input voltage of the operational amplifier (opamp), and the power supply rails. Owing to its low demand for additional components and computing resources, the proposed self-check method is cost-effective and convenient to implement. Its effectiveness and robustness are validated on a temperature sensor, an ambient light sensor, a linear variable differential transformer (LVDT) and a wireless temperature sensor node with EMI experiments using different signals parameters, temperatures and light intensities. The experimental results show that this method can enhance the measurement accuracy of analog sensors to help maintain the functioning of sensor-based systems under EMI signals.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
A Self-Check Method for Enhancing the Measurement Accuracy of Analog Sensors Under Electromagnetic Interference
Inaccurate measurements of analog sensors caused by electromagnetic interference (EMI) signals threaten the security and reliability of sensor-based systems. This article proposes a self-check method for recognizing and correcting disturbed measurements of analog sensors under EMI signals. The core basis of this method involves the use of a dummy sensing element to make the sensor sensitive only to EMI signals, rather than the measurand. This configuration enables the sensor to switch between normal mode and self-check mode through switching devices. Then the sensor response to EMI signals in normal mode is characterized by that in self-check mode, which is computable. A detailed implementation framework is derived to ensure that the sensor responses to EMI signals in both modes are highly similar, involving the properties of the dummy sensing element, the input voltage of the operational amplifier (opamp), and the power supply rails. Owing to its low demand for additional components and computing resources, the proposed self-check method is cost-effective and convenient to implement. Its effectiveness and robustness are validated on a temperature sensor, an ambient light sensor, a linear variable differential transformer (LVDT) and a wireless temperature sensor node with EMI experiments using different signals parameters, temperatures and light intensities. The experimental results show that this method can enhance the measurement accuracy of analog sensors to help maintain the functioning of sensor-based systems under EMI signals.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electronics
- Vol. 34 (1) , 114-124
Study on the Impact of Imbalance Between Transmission Lines on Crosstalk: A Novel Perspective of Displacement Current
This paper systematically studies the impact of imbalances between adjacent lines and effects on crosstalk. A novel perspective of displacement current is introduced to analyze and explain the simulated observations. The imbalances caused by coupling between single-single, single-differential, and differential-differential lines are studied and analyzed by considering the near-field coupling through the generated displacement currents. Measurements are conducted for various cases of coupled adjacent lines. An equivalent model considering the variation of displacement current with geometrical parameters is also proposed, and the corresponding coupling coefficients are extracted based on simulations to characterize the impact of imbalances. The methods and results presented in this paper provide useful guidelines for designing high-speed circuit layouts with closely spaced transmission lines.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electronics
- Vol. 34 (1) , 114-124
Study on the Impact of Imbalance Between Transmission Lines on Crosstalk: A Novel Perspective of Displacement Current
This paper systematically studies the impact of imbalances between adjacent lines and effects on crosstalk. A novel perspective of displacement current is introduced to analyze and explain the simulated observations. The imbalances caused by coupling between single-single, single-differential, and differential-differential lines are studied and analyzed by considering the near-field coupling through the generated displacement currents. Measurements are conducted for various cases of coupled adjacent lines. An equivalent model considering the variation of displacement current with geometrical parameters is also proposed, and the corresponding coupling coefficients are extracted based on simulations to characterize the impact of imbalances. The methods and results presented in this paper provide useful guidelines for designing high-speed circuit layouts with closely spaced transmission lines.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (12) , 4283-4287
An Integrated Signal Injection and Detection Broadband Near-Field Probe for Circuit Characterization
In this letter, a probe with integrated signal injection and detection is designed. By actively injecting signals into the circuit, the probe enables the identification of characteristics at different locations of the circuit. The probe features a minimum width of 4 mm, and a length of 59.32 mm. By using L-shaped structures and impedance matching techniques, the probe achieves a frequency range of 40 GHz. Additionally, the design incorporates a ground-signal-ground-signal-ground structure to ensure high isolation between the injection and detection components. Near field scanning of the microstrip line enables the realization of S-parameter and phase distributions at various frequencies, facilitating the extraction of circuit characteristics at different spatial locations.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (12) , 4283-4287
An Integrated Signal Injection and Detection Broadband Near-Field Probe for Circuit Characterization
In this letter, a probe with integrated signal injection and detection is designed. By actively injecting signals into the circuit, the probe enables the identification of characteristics at different locations of the circuit. The probe features a minimum width of 4 mm, and a length of 59.32 mm. By using L-shaped structures and impedance matching techniques, the probe achieves a frequency range of 40 GHz. Additionally, the design incorporates a ground-signal-ground-signal-ground structure to ensure high isolation between the injection and detection components. Near field scanning of the microstrip line enables the realization of S-parameter and phase distributions at various frequencies, facilitating the extraction of circuit characteristics at different spatial locations.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High Accuracy Near-Field Electromagnetic Emission Identification System Using Characteristics Recognition and Image Localization
In this paper, an automatic near-field measurement system is introduced to record the electromagnetic emission (EME) of equipment under testing (EUT). Firstly, a camera is used to capture the measurement area, which is combined with an image positioning method to achieve fast and accurate positioning of the area. Then, based on the wavelet transform and autocorrelation transform of the EME signal identification algorithm, the system further identifies the broadband and narrowband characteristics of the signal and obtains the power distributions of the corresponding characteristics. In performance tests, the near-field probe moves with a minimum stepping accuracy of 0.1 mm. The movement error of the consistency and stability are guaranteed as less than 1% of the set value. The image positioning error in the 30 cm × 30 cm scanned area is less than 0.5 mm. Finally, the system identifies EME signals from a circuit with multiple crystal oscillators and a sine signal, predictive identification of the circuit functions under the metal shell of a router system. The proposed measurement system therefore offers great measurement accuracy, stability, and efficiency.
- 13 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High Accuracy Near-Field Electromagnetic Emission Identification System Using Characteristics Recognition and Image Localization
In this paper, an automatic near-field measurement system is introduced to record the electromagnetic emission (EME) of equipment under testing (EUT). Firstly, a camera is used to capture the measurement area, which is combined with an image positioning method to achieve fast and accurate positioning of the area. Then, based on the wavelet transform and autocorrelation transform of the EME signal identification algorithm, the system further identifies the broadband and narrowband characteristics of the signal and obtains the power distributions of the corresponding characteristics. In performance tests, the near-field probe moves with a minimum stepping accuracy of 0.1 mm. The movement error of the consistency and stability are guaranteed as less than 1% of the set value. The image positioning error in the 30 cm × 30 cm scanned area is less than 0.5 mm. Finally, the system identifies EME signals from a circuit with multiple crystal oscillators and a sine signal, predictive identification of the circuit functions under the metal shell of a router system. The proposed measurement system therefore offers great measurement accuracy, stability, and efficiency.
- Open Access
- 23 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2874
A Method of Extracting Transmission Characteristics of Interconnects from Near-Field Emissions in PCBs
This paper proposes a method for extracting transmission characteristics of interconnects in printed circuit boards (PCBs) from near-field emission. A wideband microstrip line electric probe is used to measure the near-field emission. There are two key technologies in the extraction principle, obtaining the transfer function and the input signal estimation, and they are explained in detail. To validate the method, one-trace structures, including a corner trace and a via trace, and a multi-trace structure were measured. The transmission characteristics extracted by the proposed method agrees well with the standard vector network analyzer (VNA) measurements up to frequency of 12 GHz. The error caused by the distance and the disturbance signal is investigated.
- 23 February 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 2874
Open AccessA Method of Extracting Transmission Characteristics of Interconnects from Near-Field Emissions in PCBs
This paper proposes a method for extracting transmission characteristics of interconnects in printed circuit boards (PCBs) from near-field emission. A wideband microstrip line electric probe is used to measure the near-field emission. There are two key technologies in the extraction principle, obtaining the transfer function and the input signal estimation, and they are explained in detail. To validate the method, one-trace structures, including a corner trace and a via trace, and a multi-trace structure were measured. The transmission characteristics extracted by the proposed method agrees well with the standard vector network analyzer (VNA) measurements up to frequency of 12 GHz. The error caused by the distance and the disturbance signal is investigated.