YXYi Xu

Yi Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yi Xu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Haidong Zou

    Department of Ophthalmology, Shanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China

    4 shared publications
  • Lina Lu

    Shanghai Eye Disease Prevention &Treatment Center/Shanghai Eye Hospital, School of Medicine, Tongji University, China; National Clinical Research Center for Eye Diseases, China; Shanghai Engineering Research Center of Precise Diagnosis and Treatment of Eye Diseases, China; Eye Public Health Research Center, School of Medicine, Tongji University, China

    2 shared publications
  • Lina Lu

    Department of Eye Disease Control and Prevention, Shanghai Eye Disease Prevention and Treatment Center/Shanghai Eye Hospital, No. 1440, Hongqiao Road, Shanghai 200041, China

    2 shared publications
  • Saiguang Ling

    EVision Technology (Beijing) Co., Ltd., Beijing 100085, China

    2 shared publications
  • Tianyi Yuan

    Department of Ophthalmology, Shanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, No. 85/86, Wujin Road, Shanghai 200080, China

    2 shared publications
  • Xiaofeng Zhu

    Department of Preventive Ophthalmology, Shanghai Eye Disease Prevention and Treatment Center, Shanghai Eye Hospital, Shanghai, China

    2 shared publications

Latest Publications

  • Open Access

    A Novel Lactobacillus strain with Alcohol Degradation Capability and Its Beneficial Effects on the Alleviation of Alcohol Intolerance

    by Biao Chen, Hui Li, Xiaoyi Cui, Tiancheng Xu, Zhenlin Ma, Huaixu Zhu, Chen Niu, Yi Xu

    Alcohol consumption has a long-standing global history, while alcohol intolerance is a metabolic disorder syndrome characterized by a range of discomfort-related symptoms. The effective strategies to alleviate alcohol intolerance remain an unmet medical need. In this study, multiple lactic acid bacteria (LAB) probiotic strains were isolated from pickles and evaluated for their alcohol degradation capacity through in vitro catabolic assays. Among them, the strain exhibiting the highest ethanol degradation capacity was identified and designated as Lactobacillus plantarum A2 (LpA2). The ethanol metabolism by LpA2 was subsequently evaluated by co-culture with mouse ileal contents and further validated in a pilot clinical study involving 9 volunteers. Results demonstrated that LpA2 strain possesses a remarkable capability to facilitate ethanol metabolism both in vitro & in vivo. Combined with genomic sequencing data and an excellent safety profile, LpA2 displays promising translational potential as a novel food ingredient or product.

  • Open Access

    PM2.5 Exposure as a Risk Factor for Optic Nerve Health in Type 2 Diabetes Mellitus

    by Tianyi Yuan, Minna Cheng, Yingyan Ma, Haidong Zou, Haidong Kan, Xia Meng, Yi Guo, Ziwei Peng, Yi Xu, Lina Lu, et al.

    (1) Objective: This study investigated the relationship between long-term particulate matter (PM2.5) exposure and optic disc parameters—vertical cup-to-disc ratio (vCDR), vertical optic disc diameter (vDD), and vertical optic cup diameter (vCD)—in patients with type 2 diabetes mellitus (T2DM). (2) Methods: A cross-sectional analysis was conducted using data from 65,750 T2DM patients in the 2017–2018 Shanghai Cohort Study of Diabetic Eye Disease (SCODE). Optic disc parameters were extracted from fundus images, and PM2.5 exposure was estimated using a random forest model incorporating satellite and meteorological data. Multivariate linear regression models were applied, adjusting for confounders including age, gender, body mass index, blood pressure, glucose, time of T2DM duration, smoking, drinking, and physical exercise. (3) Results: A 10 μg/m3 increase in PM2.5 exposure was associated with significant reductions in vCDR (−0.008), vDD (−42.547 μm), and vCD (−30.517 μm) (all p-values < 0.001). These associations persisted after sensitivity analyses and adjustments for other pollutants like O3 and NO2. (4) Conclusions: Long-term PM2.5 exposure is associated with detrimental changes in optic disc parameters in patients with T2DM, suggesting possible optic nerve atrophy. Considering the close relationship between the optic nerve and the central nervous system, these findings may also reflect broader neurodegenerative processes.


  • Open Access

    A moderate dosage of coffee causes acute retinal capillary perfusion decrease in healthy young individuals

    by Xiaofeng Zhu, Jiong Zhu, Yongyi Wang, Zhongdi Chu, Ruikang K. Wang, Yi Xu, Lina Lu, Haidong Zou

    Aim: Caffeinated beverages are very popular across populations and cultures, but quantitative evidence of the acute effects of moderate coffee doses on retinal perfusion is sparse and contradicting. Thus, the aim of this randomized, cross-over and parallel-group design study was to investigate whether moderate consumption of coffee alters macular retinal capillary perfusion in young healthy individuals.Methods: Twenty-seven young healthy individuals were recruited for this study. Acute changes in retinal microvasculature were assessed using spectral-domain optical coherence tomography angiography (SD-OCTA) at baseline, 0.5 h, and 2 h after intake of coffee, or water. Meanwhile, cerebral blood flow (CBF) and retina-choroid blood flow were evaluated in a parallel-group design (4 participants each in coffee or water group) using magnetic resonance imaging (MRI) with pseudo-continuous arterial spin labeling sequences.Results: Two hours after coffee intake, blood caffeine concentration increased from 0 to 5.05 ± 1.36 µg/mL. Coffee caused a significant decrease in retinal vessel diameter index (VDI) (19.05 ± 0.24 versus [vs] 19.13 ± 0.26; p < 0.001) and CBF in the frontal lobe (77.47 ± 15.21 mL/100 mL/min vs. 84.13 ± 15.55 mL/100 mL/min; p < 0.05) 2 h after intake. However, it significantly increased retina-choroid blood flow after 0.5 and 2 h (163.18 ± 61.07 mL/100 mL/min vs. 132.68 ± 70.47 mL/100 mL/min, p < 0.001, and 161.21 ± 47.95 vs. 132.68 ± 70.47; p < 0.001, respectively).Conclusion: This is the first study to demonstrate the acute effects of daily dose coffee consumption on retinal capillary perfusion using SD-OCTA combinate with blood flow MRI. The findings imply that although moderate coffee intake caused a significant increase in retina-choroid blood flow, there was a significant acute decrease both in macular retinal capillary perfusion and CBF.


  • Open Access

    A Generic Pixel Pitch Calibration Method for Fundus Camera via Automated ROI Extraction

    by Tengfei Long, Yi Xu, Haidong Zou, Lina Lu, Tianyi Yuan, Zhou Dong, Jiqun Dong, Xin Ke, Saiguang Ling, Yingyan Ma

    Pixel pitch calibration is an essential step to make the fundus structures in the fundus image quantitatively measurable, which is important for the diagnosis and treatment of many diseases, e.g., diabetes, arteriosclerosis, hereditary optic atrophy, etc. The conventional calibration approaches require the specific parameters of the fundus camera or several specially shot images of the chess board, but these are generally not accessible, and the calibration results cannot be generalized to other cameras. Based on automated ROI (region of interest) and optic disc detection, the diameter ratio of ROI and optic disc (ROI–disc ratio) is quantitatively analyzed for a large number of fundus images. With the prior knowledge of the average diameter of an optic disc in fundus, the pixel pitch can be statistically estimated from a large number of fundus images captured by a specific camera without the availability of chess board images or detailed specifics of the fundus camera. Furthermore, for fundus cameras of FOV (fixed field-of-view), the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel. The average ROI–disc ratio is approximately constant, i.e., 6.404 ± 0.619 in the pixel, according to 40,600 fundus images, captured by different cameras, of 45° FOV. In consequence, the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel, and results show the pixel pitches of Canon CR2, Topcon NW400, Zeiss Visucam 200, and Newvision RetiCam 3100 cameras are 6.825 ± 0.666 μm, 6.625 ± 0.647 μm, 5.793 ± 0.565 μm, and 5.884 ± 0.574 μm, respectively. Compared with the manually measured pixel pitches, based on the method of ISO 10940:2009, i.e., 6.897 μm, 6.807 μm, 5.693 μm, and 6.050 μm, respectively, the bias of the proposed method is less than 5%. Since our method doesn’t require chess board images or detailed specifics, the fundus structures on the fundus image can be measured accurately, according to the pixel pitch obtained by this method, without knowing the type and parameters of the camera.


  • Open Access

    Disparities Between People with Diabetic Retinopathy and Community Health Service Centers’ Staff in Estimating Satisfaction with Telescreening for Diabetic Eye Diseases

    by Xiaofeng Zhu, Yi Xu, Lina Lu, Haidong Zou

    Background The success of the telescreening and management for diabetic retinopathy (DR) in the communities depends on the satisfaction of the people with diabetes, and the community health service centers (CHSCs)’ staff, referred to as providers. To investigate the satisfaction of people with DR and CHSCs’ staff, with the comprehensive management system for diabetic eye diseases (abbreviated as “the System” in the following text). Methods This cross-sectional survey for those receiving the service, included 3817 people with vision-threatening DR (VTDR), focused on the satisfaction with the System, including telescreening process, speed of feedback, interpretation of results, awareness of the related diseases, and eye care service. The survey for the providers, included 234 CHSCs’ staff focused on satisfaction and main barriers encountered during the implementation of the System. Sociodemographic characteristics and perceived barriers related to satisfaction were identified by conducting univariate and multivariate logistic regression analyses. Results The overall satisfaction of those receiving the service was 96.0%, and 75.8% of them were willing to undergo telescreening for DR the following year. The convenience of telescreening, reasonable and orderly telescreening, and improvement in the related disease awareness significantly correlated with satisfaction. Only 48.3% of the providers were satisfied with the System. The three most mentioned barriers to the development of the System were insufficient technical staff, inadequate funds, and incomplete information transmission system. Conclusions Disparities between the high satisfaction of those receiving the service and the low satisfaction of the providers with the System were mainly related to the current weak ophthalmic medical level in the CHSCs and the low awareness of screening for diabetic eye diseases among not only people with DR but the CHSCs’ staff.