Saiguang Ling
Saiguang Ling has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Haidong Zou
Department of Ophthalmology, Shanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Lina Lu
Department of Eye Disease Control and Prevention, Shanghai Eye Disease Prevention and Treatment Center/Shanghai Eye Hospital, No. 1440, Hongqiao Road, Shanghai 200041, China
2 shared publications - Tianyi Yuan
Department of Ophthalmology, Shanghai General Hospital, School of Medicine, Shanghai Jiao Tong University, No. 85/86, Wujin Road, Shanghai 200080, China
2 shared publications - Yi Xu
Shanghai Eye Disease Prevention &Treatment Center/Shanghai Eye Hospital, School of Medicine, Tongji University, China; National Clinical Research Center for Eye Diseases, China; Shanghai Engineering Research Center of Precise Diagnosis and Treatment of Eye Diseases, China; Eye Public Health Research Center, School of Medicine, Tongji University, China
2 shared publications - Yingyan Ma
Department of Eye Disease Control and Prevention, Shanghai Eye Disease Prevention & Treatment Center/Shanghai Eye Hospital, School of Medicine, Tongji University, Shanghai, China
2 shared publications - Zhou Dong
EVision Technology (Beijing) Co., Ltd., Beijing 100085, China
2 shared publications
Latest Publications
- Open Access
PM2.5 Exposure as a Risk Factor for Optic Nerve Health in Type 2 Diabetes Mellitus
(1) Objective: This study investigated the relationship between long-term particulate matter (PM2.5) exposure and optic disc parameters—vertical cup-to-disc ratio (vCDR), vertical optic disc diameter (vDD), and vertical optic cup diameter (vCD)—in patients with type 2 diabetes mellitus (T2DM). (2) Methods: A cross-sectional analysis was conducted using data from 65,750 T2DM patients in the 2017–2018 Shanghai Cohort Study of Diabetic Eye Disease (SCODE). Optic disc parameters were extracted from fundus images, and PM2.5 exposure was estimated using a random forest model incorporating satellite and meteorological data. Multivariate linear regression models were applied, adjusting for confounders including age, gender, body mass index, blood pressure, glucose, time of T2DM duration, smoking, drinking, and physical exercise. (3) Results: A 10 μg/m3 increase in PM2.5 exposure was associated with significant reductions in vCDR (−0.008), vDD (−42.547 μm), and vCD (−30.517 μm) (all p-values < 0.001). These associations persisted after sensitivity analyses and adjustments for other pollutants like O3 and NO2. (4) Conclusions: Long-term PM2.5 exposure is associated with detrimental changes in optic disc parameters in patients with T2DM, suggesting possible optic nerve atrophy. Considering the close relationship between the optic nerve and the central nervous system, these findings may also reflect broader neurodegenerative processes.
Open AccessPM2.5 Exposure as a Risk Factor for Optic Nerve Health in Type 2 Diabetes Mellitus
(1) Objective: This study investigated the relationship between long-term particulate matter (PM2.5) exposure and optic disc parameters—vertical cup-to-disc ratio (vCDR), vertical optic disc diameter (vDD), and vertical optic cup diameter (vCD)—in patients with type 2 diabetes mellitus (T2DM). (2) Methods: A cross-sectional analysis was conducted using data from 65,750 T2DM patients in the 2017–2018 Shanghai Cohort Study of Diabetic Eye Disease (SCODE). Optic disc parameters were extracted from fundus images, and PM2.5 exposure was estimated using a random forest model incorporating satellite and meteorological data. Multivariate linear regression models were applied, adjusting for confounders including age, gender, body mass index, blood pressure, glucose, time of T2DM duration, smoking, drinking, and physical exercise. (3) Results: A 10 μg/m3 increase in PM2.5 exposure was associated with significant reductions in vCDR (−0.008), vDD (−42.547 μm), and vCD (−30.517 μm) (all p-values < 0.001). These associations persisted after sensitivity analyses and adjustments for other pollutants like O3 and NO2. (4) Conclusions: Long-term PM2.5 exposure is associated with detrimental changes in optic disc parameters in patients with T2DM, suggesting possible optic nerve atrophy. Considering the close relationship between the optic nerve and the central nervous system, these findings may also reflect broader neurodegenerative processes.
- Open Access
- 26 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 267
Distinctive Imaging Characteristics of Retinal and Cerebral Vessels between Central and Branch Retinal Vein Occlusion by MRI and AI-Based Image Analyzer
Retinal vessels have been good predictive and prognostic imaging biomarkers for systemic or eye diseases. Numerous studies have shown that the two retinal vein occlusion entities may correlate with cardiovascular and cerebrovascular events or primary open-angle glaucoma. This study aims to investigate if there is a disparity in the correlations between branch RVO (BRVO) and central RVO (CRVO) with systemic disorders or POAG, thus explaining the pathogenic difference between BRVO and CRVO. This retrospective case-control study enrolled 59 RVO subjects (118 eyes), including 25 CRVO and 34 BRVO subjects, who received routine eye and brain MRI examinations. The geometric characteristics of the caliber of the retinal and cerebral blood vessels and the optic nerve subarachnoid space width (ONSASW) were measured. Multivariable logistic regression analysis showed that ONSASW at 3 mm behind the globe (p = 0.044) and the relative retinal venular calibers (p = 0.031) were independent risk factors for the CRVO-affected eyes group in comparison with the BRVO-affected eyes group after adjusting for age, duration of hypertension, BMI, and IOP. In the CRVO-affected eyes, narrower relative retinal arteriolar calibers (p = 0.041) and wider relative venular calibers (p = 0.011) were independent risk factors compared with the CRVO-contralateral normal eyes when adjusting for IOP. We concluded that BRVO may be more associated with cerebrovascular diseases, and CRVO may be correlated with primary angle glaucoma. The geometric characteristics difference between the retinal and cerebrovascular may explain the pathological difference between CRVO and BRVO.
- 26 January 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (3) , 267
Open AccessDistinctive Imaging Characteristics of Retinal and Cerebral Vessels between Central and Branch Retinal Vein Occlusion by MRI and AI-Based Image Analyzer
Retinal vessels have been good predictive and prognostic imaging biomarkers for systemic or eye diseases. Numerous studies have shown that the two retinal vein occlusion entities may correlate with cardiovascular and cerebrovascular events or primary open-angle glaucoma. This study aims to investigate if there is a disparity in the correlations between branch RVO (BRVO) and central RVO (CRVO) with systemic disorders or POAG, thus explaining the pathogenic difference between BRVO and CRVO. This retrospective case-control study enrolled 59 RVO subjects (118 eyes), including 25 CRVO and 34 BRVO subjects, who received routine eye and brain MRI examinations. The geometric characteristics of the caliber of the retinal and cerebral blood vessels and the optic nerve subarachnoid space width (ONSASW) were measured. Multivariable logistic regression analysis showed that ONSASW at 3 mm behind the globe (p = 0.044) and the relative retinal venular calibers (p = 0.031) were independent risk factors for the CRVO-affected eyes group in comparison with the BRVO-affected eyes group after adjusting for age, duration of hypertension, BMI, and IOP. In the CRVO-affected eyes, narrower relative retinal arteriolar calibers (p = 0.041) and wider relative venular calibers (p = 0.011) were independent risk factors compared with the CRVO-contralateral normal eyes when adjusting for IOP. We concluded that BRVO may be more associated with cerebrovascular diseases, and CRVO may be correlated with primary angle glaucoma. The geometric characteristics difference between the retinal and cerebrovascular may explain the pathological difference between CRVO and BRVO.
- Open Access
A Generic Pixel Pitch Calibration Method for Fundus Camera via Automated ROI Extraction
Pixel pitch calibration is an essential step to make the fundus structures in the fundus image quantitatively measurable, which is important for the diagnosis and treatment of many diseases, e.g., diabetes, arteriosclerosis, hereditary optic atrophy, etc. The conventional calibration approaches require the specific parameters of the fundus camera or several specially shot images of the chess board, but these are generally not accessible, and the calibration results cannot be generalized to other cameras. Based on automated ROI (region of interest) and optic disc detection, the diameter ratio of ROI and optic disc (ROI–disc ratio) is quantitatively analyzed for a large number of fundus images. With the prior knowledge of the average diameter of an optic disc in fundus, the pixel pitch can be statistically estimated from a large number of fundus images captured by a specific camera without the availability of chess board images or detailed specifics of the fundus camera. Furthermore, for fundus cameras of FOV (fixed field-of-view), the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel. The average ROI–disc ratio is approximately constant, i.e., 6.404 ± 0.619 in the pixel, according to 40,600 fundus images, captured by different cameras, of 45° FOV. In consequence, the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel, and results show the pixel pitches of Canon CR2, Topcon NW400, Zeiss Visucam 200, and Newvision RetiCam 3100 cameras are 6.825 ± 0.666 μm, 6.625 ± 0.647 μm, 5.793 ± 0.565 μm, and 5.884 ± 0.574 μm, respectively. Compared with the manually measured pixel pitches, based on the method of ISO 10940:2009, i.e., 6.897 μm, 6.807 μm, 5.693 μm, and 6.050 μm, respectively, the bias of the proposed method is less than 5%. Since our method doesn’t require chess board images or detailed specifics, the fundus structures on the fundus image can be measured accurately, according to the pixel pitch obtained by this method, without knowing the type and parameters of the camera.
Open AccessA Generic Pixel Pitch Calibration Method for Fundus Camera via Automated ROI Extraction
Pixel pitch calibration is an essential step to make the fundus structures in the fundus image quantitatively measurable, which is important for the diagnosis and treatment of many diseases, e.g., diabetes, arteriosclerosis, hereditary optic atrophy, etc. The conventional calibration approaches require the specific parameters of the fundus camera or several specially shot images of the chess board, but these are generally not accessible, and the calibration results cannot be generalized to other cameras. Based on automated ROI (region of interest) and optic disc detection, the diameter ratio of ROI and optic disc (ROI–disc ratio) is quantitatively analyzed for a large number of fundus images. With the prior knowledge of the average diameter of an optic disc in fundus, the pixel pitch can be statistically estimated from a large number of fundus images captured by a specific camera without the availability of chess board images or detailed specifics of the fundus camera. Furthermore, for fundus cameras of FOV (fixed field-of-view), the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel. The average ROI–disc ratio is approximately constant, i.e., 6.404 ± 0.619 in the pixel, according to 40,600 fundus images, captured by different cameras, of 45° FOV. In consequence, the pixel pitch of a fundus image of 45° FOV can be directly estimated according to the automatically measured diameter of ROI in the pixel, and results show the pixel pitches of Canon CR2, Topcon NW400, Zeiss Visucam 200, and Newvision RetiCam 3100 cameras are 6.825 ± 0.666 μm, 6.625 ± 0.647 μm, 5.793 ± 0.565 μm, and 5.884 ± 0.574 μm, respectively. Compared with the manually measured pixel pitches, based on the method of ISO 10940:2009, i.e., 6.897 μm, 6.807 μm, 5.693 μm, and 6.050 μm, respectively, the bias of the proposed method is less than 5%. Since our method doesn’t require chess board images or detailed specifics, the fundus structures on the fundus image can be measured accurately, according to the pixel pitch obtained by this method, without knowing the type and parameters of the camera.