Guanpin Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guanpin Ren has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Shuang Liu
College of Physics, Chengdu University of Technology, Chengdu 610059, China
2 shared publications - Wei Jiang
Chengdu Development Center of Science and Technology of CAEP, Chengdu 610299, China
2 shared publications - Cheng Liao
Chengdu Development Center of Science and Technology of CAEP, Chengdu 610299, China
1 shared publication - Huan Zhan
Chengdu Development Center of Science and Technology of CAEP, Chengdu 610299, China
1 shared publication - Huan Zhan
FSC Innovations (Chengdu) Optoelectronics Technology Co., Ltd., Chengdu 610299, China
1 shared publication - Kun Luo
Chengdu Development Center of Science and Technology of CAEP, Chengdu 610299, China
1 shared publication
Latest Publications
- Open Access
Ultrasonic Measurement of Axial Preload in High-Frequency Nickel-Based Superalloy Smart Bolt
A high-frequency, piezoelectric thin-film sensor was successfully deposited on a nickel-based superalloy bolt by radio frequency magnetron sputtering to develop a smart, nickel-based superalloy bolt. Ultrasonic response characterization, high accuracy, and repeatability of ultrasonic measurement of axial preload in nickel-based superalloy smart bolts are reported here and were fully demonstrated. The axial preload in the nickel-based superalloy smart bolt was directly measured by the bi-wave method (TOF ratio between transverse and longitudinal-mode waves) without using the traditional integration of a longitudinal and shear transducer. A model concerning the bolt before and after tensioning was established to demonstrate the propagation and displacement distribution of the ultrasonic waves inside a nickel-based superalloy smart bolt. The measured A-scan signal presented significantly favorable features including a mixture of transverse and longitudinal mode waves, a pure and broad frequency spectrum which peaked at 17.14 MHz, and high measurement accuracy below 3% for tension of 4 kN–20 kN. For the temporal ultrasonic signal, the measurement envelopes were narrower than for the counterpart of the simulation, justifying the ‘filtration’ advantage of the high-frequency sensor. Both the TOF change of the single longitudinal-mode wave and the TOF ratio between transverse- and longitudinal-mode waves increased linearly with preload force in the range of 0 kN to 20 kN. Compared with the commercial piezoelectric probe, the proposed probe, based on the combination of a high-frequency, piezoelectric thin-film sensor and a magnetically mounted transducer connector, exhibited high tolerance to temperatures as high as 320 °C and high repeatability free from some interference factors such as bolt detection position change and couplant layer thickness. The results indicate that this system is a promising axial preload measurement system for high-temperature fasteners and connectors, and the proposed sensor is a practical, high-frequency ultrasonic sensor for non-destructive testing.
Open AccessUltrasonic Measurement of Axial Preload in High-Frequency Nickel-Based Superalloy Smart Bolt
A high-frequency, piezoelectric thin-film sensor was successfully deposited on a nickel-based superalloy bolt by radio frequency magnetron sputtering to develop a smart, nickel-based superalloy bolt. Ultrasonic response characterization, high accuracy, and repeatability of ultrasonic measurement of axial preload in nickel-based superalloy smart bolts are reported here and were fully demonstrated. The axial preload in the nickel-based superalloy smart bolt was directly measured by the bi-wave method (TOF ratio between transverse and longitudinal-mode waves) without using the traditional integration of a longitudinal and shear transducer. A model concerning the bolt before and after tensioning was established to demonstrate the propagation and displacement distribution of the ultrasonic waves inside a nickel-based superalloy smart bolt. The measured A-scan signal presented significantly favorable features including a mixture of transverse and longitudinal mode waves, a pure and broad frequency spectrum which peaked at 17.14 MHz, and high measurement accuracy below 3% for tension of 4 kN–20 kN. For the temporal ultrasonic signal, the measurement envelopes were narrower than for the counterpart of the simulation, justifying the ‘filtration’ advantage of the high-frequency sensor. Both the TOF change of the single longitudinal-mode wave and the TOF ratio between transverse- and longitudinal-mode waves increased linearly with preload force in the range of 0 kN to 20 kN. Compared with the commercial piezoelectric probe, the proposed probe, based on the combination of a high-frequency, piezoelectric thin-film sensor and a magnetically mounted transducer connector, exhibited high tolerance to temperatures as high as 320 °C and high repeatability free from some interference factors such as bolt detection position change and couplant layer thickness. The results indicate that this system is a promising axial preload measurement system for high-temperature fasteners and connectors, and the proposed sensor is a practical, high-frequency ultrasonic sensor for non-destructive testing.
- Open Access
Evaluation of Axial Preload in Different-Frequency Smart Bolts by Laser Ultrasound
We report here on a laser ultrasonic system to indirectly evaluate the preload force of different-frequency piezoelectric bolts. This newly developed system enables us to achieve the goal of non-contact excitation and synchronously collects the laser-induced ultrasonic signal by the combination of a smart piezoelectric sensor and a magnetically mounted transducer connector. A numerical model based on the finite element method (FEM) was developed to simulate the propagation and displacement distribution of laser-generated ultrasonic waves along the axial direction. The measured A-scan waveform basically coincided with the counterpart obtained from a theoretical simulation, confirming the effectiveness of the proposed system to measure a bolt. By comparison, a laser spot diameter of 6 mm was the optimal beam diameter for the excitation of the ultrasonic wave in the bolt. The linear relationship between time of flight (TOF) of the ultrasonic longitudinal wave and bolt torque was almost independent from the center frequency of the smart bolt. By contrast, a piezoelectric patch centered at 5 MHz was more suitable as an ultrasonic sensor in terms of the nonlinear effects component suppression and linear fitting degree between TOF and torque. The results indicate that the proposed system based on a surface-mounted piezoelectric sensor is a promising system for evaluating the axial preload change of connector and fastener and is an additional potential laser ultrasonic system for nondestructive tests.
Open AccessEvaluation of Axial Preload in Different-Frequency Smart Bolts by Laser Ultrasound
We report here on a laser ultrasonic system to indirectly evaluate the preload force of different-frequency piezoelectric bolts. This newly developed system enables us to achieve the goal of non-contact excitation and synchronously collects the laser-induced ultrasonic signal by the combination of a smart piezoelectric sensor and a magnetically mounted transducer connector. A numerical model based on the finite element method (FEM) was developed to simulate the propagation and displacement distribution of laser-generated ultrasonic waves along the axial direction. The measured A-scan waveform basically coincided with the counterpart obtained from a theoretical simulation, confirming the effectiveness of the proposed system to measure a bolt. By comparison, a laser spot diameter of 6 mm was the optimal beam diameter for the excitation of the ultrasonic wave in the bolt. The linear relationship between time of flight (TOF) of the ultrasonic longitudinal wave and bolt torque was almost independent from the center frequency of the smart bolt. By contrast, a piezoelectric patch centered at 5 MHz was more suitable as an ultrasonic sensor in terms of the nonlinear effects component suppression and linear fitting degree between TOF and torque. The results indicate that the proposed system based on a surface-mounted piezoelectric sensor is a promising system for evaluating the axial preload change of connector and fastener and is an additional potential laser ultrasonic system for nondestructive tests.