Huan Zhan
Huan Zhan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shuang Liu
College of Physics, Chengdu University of Technology, Chengdu 610059, China
3 shared publications - Cheng Liao
Chengdu Development Center of Science and Technology of CAEP, Chengdu 610299, China
1 shared publication - Guanghua Cheng
School of Artificial Intelligence, Optics and Electronics (iOPEN), Northwestern Polytechnical University, Xi’an 710072, China
1 shared publication Guanpin Ren
Department of Applied Physics, College of Mathematics and Physics, Chengdu University of Technology 1 , Chengdu 610059, China
1 shared publication- Guanpin Ren
Department of Applied Physics, College of Mathematics and Physics, Chengdu University of Technology, Chengdu 610059, China
1 shared publication - Hai Wang
Sichuan Gaolu Traffic Information Engineering Co., Ltd., Chengdu 610095, China
1 shared publication
Latest Publications
- Open Access
Direct μJ-Level Femtosecond Laser Welding of Fused Silica to Titanium Foil Without Interlayer
Direct welding of fused silica to pure titanium (Ti) foil using conventional methods faces significant challenges, such as poor interfacial wettability, insufficient joint strength, and the need for interlayers or surface pretreatments. Existing femtosecond (fs) laser welding techniques for these materials often require high-energy millijoule (mJ)-level pulses or alloy interlayers. Moreover, reports on direct microjoule (μJ)-level fs laser welding of Ti foil to fused silica remain scarce. This study successfully demonstrates a direct welding process for pure Ti foil and fused silica using μJ-level fs laser pulses under ambient conditions, achieving joints with a maximum shear strength of 9.19 MPa. Microstructural analysis revealed an elemental interdiffusion region at the weld interface, supported by mechanical interlocking effects. X-ray photoelectron spectroscopy (XPS) confirmed the occurrence of interfacial chemical reactions, forming titanium silicide (TiSi2) and titanium oxide (TiO2). Additionally, a 24 h water immersion test of a square sealed cavity revealed outstanding hermeticity, with no water ingress. This work provides a simple, efficient, and robust solution for high-strength, additive-free bonding of fused silica to Ti foil under low-energy processing conditions.
Open AccessDirect μJ-Level Femtosecond Laser Welding of Fused Silica to Titanium Foil Without Interlayer
Direct welding of fused silica to pure titanium (Ti) foil using conventional methods faces significant challenges, such as poor interfacial wettability, insufficient joint strength, and the need for interlayers or surface pretreatments. Existing femtosecond (fs) laser welding techniques for these materials often require high-energy millijoule (mJ)-level pulses or alloy interlayers. Moreover, reports on direct microjoule (μJ)-level fs laser welding of Ti foil to fused silica remain scarce. This study successfully demonstrates a direct welding process for pure Ti foil and fused silica using μJ-level fs laser pulses under ambient conditions, achieving joints with a maximum shear strength of 9.19 MPa. Microstructural analysis revealed an elemental interdiffusion region at the weld interface, supported by mechanical interlocking effects. X-ray photoelectron spectroscopy (XPS) confirmed the occurrence of interfacial chemical reactions, forming titanium silicide (TiSi2) and titanium oxide (TiO2). Additionally, a 24 h water immersion test of a square sealed cavity revealed outstanding hermeticity, with no water ingress. This work provides a simple, efficient, and robust solution for high-strength, additive-free bonding of fused silica to Ti foil under low-energy processing conditions.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Fabrication and characterization of smart titanium alloy bolt based on high-frequency piezoelectric thin-film
We reported here on the fabrication and characterization of a smart titanium alloy bolt based on a high-frequency piezoelectric thin-film sensor. The thin-film sensor was directly deposited on a titanium alloy bolt head with radio frequency magnetron sputtering and characterized by a scanning electron microscope and an atomic force microscope. The ultrasonic characteristics of the smart bolt, which include a pure and broad frequency spectrum peaked at 14.81 MHz, high measurement accuracy below 3%, and high repeatability free from some interference from bolt detection position change, were fully characterized. No obvious frequency shift was observed with the increase in axial preload. Based on the mono-wave method [TOF (time of flight) of longitudinal mode wave], TOF change increased linearly with preload force in the range of 0–20 kN. With the increase in temperature from 22 to 150 °C, the TOF linearly increases while the longitudinal wave velocity linearly decreases. The results indicate the prepared smart titanium alloy bolt is suitable as a smart aviation and automotive fastener.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Fabrication and characterization of smart titanium alloy bolt based on high-frequency piezoelectric thin-film
We reported here on the fabrication and characterization of a smart titanium alloy bolt based on a high-frequency piezoelectric thin-film sensor. The thin-film sensor was directly deposited on a titanium alloy bolt head with radio frequency magnetron sputtering and characterized by a scanning electron microscope and an atomic force microscope. The ultrasonic characteristics of the smart bolt, which include a pure and broad frequency spectrum peaked at 14.81 MHz, high measurement accuracy below 3%, and high repeatability free from some interference from bolt detection position change, were fully characterized. No obvious frequency shift was observed with the increase in axial preload. Based on the mono-wave method [TOF (time of flight) of longitudinal mode wave], TOF change increased linearly with preload force in the range of 0–20 kN. With the increase in temperature from 22 to 150 °C, the TOF linearly increases while the longitudinal wave velocity linearly decreases. The results indicate the prepared smart titanium alloy bolt is suitable as a smart aviation and automotive fastener.
- Open Access
Ultrasonic Measurement of Axial Preload in High-Frequency Nickel-Based Superalloy Smart Bolt
A high-frequency, piezoelectric thin-film sensor was successfully deposited on a nickel-based superalloy bolt by radio frequency magnetron sputtering to develop a smart, nickel-based superalloy bolt. Ultrasonic response characterization, high accuracy, and repeatability of ultrasonic measurement of axial preload in nickel-based superalloy smart bolts are reported here and were fully demonstrated. The axial preload in the nickel-based superalloy smart bolt was directly measured by the bi-wave method (TOF ratio between transverse and longitudinal-mode waves) without using the traditional integration of a longitudinal and shear transducer. A model concerning the bolt before and after tensioning was established to demonstrate the propagation and displacement distribution of the ultrasonic waves inside a nickel-based superalloy smart bolt. The measured A-scan signal presented significantly favorable features including a mixture of transverse and longitudinal mode waves, a pure and broad frequency spectrum which peaked at 17.14 MHz, and high measurement accuracy below 3% for tension of 4 kN–20 kN. For the temporal ultrasonic signal, the measurement envelopes were narrower than for the counterpart of the simulation, justifying the ‘filtration’ advantage of the high-frequency sensor. Both the TOF change of the single longitudinal-mode wave and the TOF ratio between transverse- and longitudinal-mode waves increased linearly with preload force in the range of 0 kN to 20 kN. Compared with the commercial piezoelectric probe, the proposed probe, based on the combination of a high-frequency, piezoelectric thin-film sensor and a magnetically mounted transducer connector, exhibited high tolerance to temperatures as high as 320 °C and high repeatability free from some interference factors such as bolt detection position change and couplant layer thickness. The results indicate that this system is a promising axial preload measurement system for high-temperature fasteners and connectors, and the proposed sensor is a practical, high-frequency ultrasonic sensor for non-destructive testing.
Open AccessUltrasonic Measurement of Axial Preload in High-Frequency Nickel-Based Superalloy Smart Bolt
A high-frequency, piezoelectric thin-film sensor was successfully deposited on a nickel-based superalloy bolt by radio frequency magnetron sputtering to develop a smart, nickel-based superalloy bolt. Ultrasonic response characterization, high accuracy, and repeatability of ultrasonic measurement of axial preload in nickel-based superalloy smart bolts are reported here and were fully demonstrated. The axial preload in the nickel-based superalloy smart bolt was directly measured by the bi-wave method (TOF ratio between transverse and longitudinal-mode waves) without using the traditional integration of a longitudinal and shear transducer. A model concerning the bolt before and after tensioning was established to demonstrate the propagation and displacement distribution of the ultrasonic waves inside a nickel-based superalloy smart bolt. The measured A-scan signal presented significantly favorable features including a mixture of transverse and longitudinal mode waves, a pure and broad frequency spectrum which peaked at 17.14 MHz, and high measurement accuracy below 3% for tension of 4 kN–20 kN. For the temporal ultrasonic signal, the measurement envelopes were narrower than for the counterpart of the simulation, justifying the ‘filtration’ advantage of the high-frequency sensor. Both the TOF change of the single longitudinal-mode wave and the TOF ratio between transverse- and longitudinal-mode waves increased linearly with preload force in the range of 0 kN to 20 kN. Compared with the commercial piezoelectric probe, the proposed probe, based on the combination of a high-frequency, piezoelectric thin-film sensor and a magnetically mounted transducer connector, exhibited high tolerance to temperatures as high as 320 °C and high repeatability free from some interference factors such as bolt detection position change and couplant layer thickness. The results indicate that this system is a promising axial preload measurement system for high-temperature fasteners and connectors, and the proposed sensor is a practical, high-frequency ultrasonic sensor for non-destructive testing.