SBSrinivas Bolem

Srinivas Bolem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Srinivas Bolem has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Histopathology-based near-realistic arterial wall reconstruction of a patient-specific cerebral aneurysm for fluid-structure interaction studies

    by Azhaganmaadevi K. Alagan, Chanikya Valeti, Srinivas Bolem, Omkar Sanjay Karve, K.R. Arvind, P. Rajalakshmi, A. Sabareeswaran, Suraj Gopal, Gowtham Matham, H.R. Darshan, et al.


  • Influence of wall thickness on the rupture risk of a patient-specific cerebral aneurysm: A fluid–structure interaction study

    by Chanikya Valeti, Srinivas Bolem, Azhaganmaadevi K. Alagan, B. J. Sudhir, Santhosh K. Kannath, Bhushan Akhade, Gowtham Matham, K Krishnakumar, B. S. V. Patnaik

    Cerebral aneurysms are the bulges in arteries that have the potential to rupture, as thin-walled regions of an aneurysm are more vulnerable. Understanding the correlation between the wall thickness and the corresponding wall stresses can facilitate better prediction using fluid–structure interaction tools. However, obtaining the actual in vivo wall thickness variation of the aneurysm dome and neck is vital for an accurate prediction of wall stresses. Invasive methods of obtaining wall thickness variation of an abnormal artery may further aggravate the rupture risk of these aneurysms. Modeling aneurysmal wall thickness reconstruction, closer to the in vivo conditions from the histopathological slices, is an apt approach to follow. To this end, the present study performs a comparative assessment of uniform, variable, and patient-specific wall thickness on the hemodynamic and biomechanical wall stresses. Simulations show that maximum wall stresses for the uniform, variable, and patient-specific wall thickness are 13.6, 27.6, and 48.4 kPa, respectively. The maximum wall displacements for the uniform, variable, and patient-specific wall thickness were observed to be 58.5, 126, and 162 μm, respectively. It is observed that the uniform wall thickness model is conservative and underestimates the risk in the prediction of biomechanical stresses and wall displacements. Thinner wall regions experience higher stress for the same internal pressure than thicker wall regions, indicating regions that are more susceptible to rupture. The generation of a variable wall thickness model was observed to be an apt approach, as patient-specific wall thickness information can only be retrospective in the current scientific scenario.


  • Patient-specific arterial wall generation for intracranial aneurysms with a variable and a near realistic vessel wall thickness for FSI studies

    by Srinivas Bolem, Chanikya Valeti, Nimmy Thankom Philip, B.J. Sudhir, B.S.V. Patnaik

    Imaging methodologies such as, computed tomography (CT) aid in three-dimensional (3D) reconstruction of patient-specific aneurysms. The radiological data is useful in understanding their location, shape, size, and disease progression. However, there are serious impediments in discerning the blood vessel wall thickness due to limitations in the current imaging modalities. This further restricts the ability to perform high-fidelity fluid structure interaction (FSI) studies for an accurate assessment of rupture risk. FSI studies would require the arterial wall mesh to be generated to determine realistic maximum allowable wall stresses by performing coupled calculations for the hemodynamic forces with the arterial walls. In the present study, a novel methodology is developed to geometrically model variable vessel wall thickness for the lumen isosurface extracted from CT scan slices of patient-specific aneurysms based on clinical and histopathological inputs. FSI simulations are carried out with the reconstructed models to assess the importance of near realistic wall thickness model on rupture risk predictions. During surgery, clinicians often observe translucent vessel walls, indicating the presence of thin regions. The need to generate variable vessel wall thickness model, that embodies the wall thickness gradation, is closer to such clinical observations. Hence, corresponding FSI simulations performed can improve clinical outcomes. Considerable differences in the magnitude of instantaneous wall shear stresses and von Mises stresses in the walls of the aneurysm was observed between a uniform wall thickness and a variable wall thickness model. In the present study, a variable vessel wall thickness generation algorithm is implemented. It was shown that, a realistic wall thickness modeling is necessary for an accurate prediction of the shear stresses on the wall as well as von Mises stresses in the wall. FSI simulations are performed to demonstrate the utility of variable wall thickness modeling.