Haider H. Haider
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haider H. Haider has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Haider Sattar Faraj
Department of Civil Engineering, Engineering College, University of Misan, Amarah, Iraq
2 shared publications - Hayder Al-Khazraji
Department of Civil Engineering , University of Misan , Iraq
2 shared publications - Majed Ali Mozan
Department of Civil Engineering, Engineering College, University of Misan, Amarah, Iraq
2 shared publications - Sajjad Sadiq Maktuf
Department of Civil Engineering, Engineering College, University of Misan, Amarah, Iraq
2 shared publications Abdulkhaliq A. Jaafer
University of Misan
1 shared publication- Abdulkhaliq Abdulyimah Jaafer
Misan University
1 shared publication
Latest Publications
- Open Access
Behavior of Ferrocement Reinforced Concrete Beams Incorporating Waste Glass Exposed to Fire
This study is an experiment that looks at what happens when 18 supported reinforced concrete beams with waste glass inside them are put on fire. All the supported beams were tested under a three-point load. We classified the beams into three groups based on the glass-to-sand replacement ratio. Two sand replacement ratios (10% and 20%) were considered and compared with the control beams (without replacement). Two periods of burning were studied to investigate the mechanical properties of ferrocement and the behavior of simply supported beams. We considered a temperature of 550 °C and gradually increased the burning to reach this degree. Mode failure, mechanical properties, and load–deflection were present in this study. According to this study and its results, it seems that approximately all mode failures were compound flexural and shear failures. The flexural and compressive strength of replacing sand with glass concrete leads to an improvement in the flexural behavior of the reinforced concrete beam incorporating waste glass (brittle failure) that happened when burning the beam element without sand replacement glasses. The replacement ratio (10%) is the best value of the replacement ratio of the glasses; the compressive strength increased by about 10% to 29% by the replacement ratio. When replacing 10% of the sand with glasses, the ratio increases from 1% to 16%, but the compressive strength decreases from 20% to 51% when the burning time increases from one hour to an hour and a half. When 10% of the sand is replaced by glasses by weight, the first crack load capacity goes up by about 8% for one hour of burning and by 16% for one hour and a half of burning compared to beams that are not burning. The ultimate load capacity also goes up by about 17.5% for one hour of burning and by 23.5% for one hour and a half of burning compared to beams that are not burning. Otherwise, sand replacement was 10% by glasses; by weight, the ultimate load strength increased about 6% when the burning was one hour and 12% when the burning was one hour and a half compared with the beams without burning for the same phase.
Open AccessBehavior of Ferrocement Reinforced Concrete Beams Incorporating Waste Glass Exposed to Fire
This study is an experiment that looks at what happens when 18 supported reinforced concrete beams with waste glass inside them are put on fire. All the supported beams were tested under a three-point load. We classified the beams into three groups based on the glass-to-sand replacement ratio. Two sand replacement ratios (10% and 20%) were considered and compared with the control beams (without replacement). Two periods of burning were studied to investigate the mechanical properties of ferrocement and the behavior of simply supported beams. We considered a temperature of 550 °C and gradually increased the burning to reach this degree. Mode failure, mechanical properties, and load–deflection were present in this study. According to this study and its results, it seems that approximately all mode failures were compound flexural and shear failures. The flexural and compressive strength of replacing sand with glass concrete leads to an improvement in the flexural behavior of the reinforced concrete beam incorporating waste glass (brittle failure) that happened when burning the beam element without sand replacement glasses. The replacement ratio (10%) is the best value of the replacement ratio of the glasses; the compressive strength increased by about 10% to 29% by the replacement ratio. When replacing 10% of the sand with glasses, the ratio increases from 1% to 16%, but the compressive strength decreases from 20% to 51% when the burning time increases from one hour to an hour and a half. When 10% of the sand is replaced by glasses by weight, the first crack load capacity goes up by about 8% for one hour of burning and by 16% for one hour and a half of burning compared to beams that are not burning. The ultimate load capacity also goes up by about 17.5% for one hour of burning and by 23.5% for one hour and a half of burning compared to beams that are not burning. Otherwise, sand replacement was 10% by glasses; by weight, the ultimate load strength increased about 6% when the burning was one hour and 12% when the burning was one hour and a half compared with the beams without burning for the same phase.
- 2 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- p. 1-14
New technique used for strengthening jack arch slabs
- 2 February 2023
- Published by Springer Nature in Asian Journal of Civil Engineering
- p. 1-14
New technique used for strengthening jack arch slabs
- Open Access
- 10 November 2022
- Published by Springer Nature in Research Square
New Technique Used for Strengthening Jack Arch Slab
The use of fiber-reinforced polymer rope (FRPR) increases the seismic performance of clay-brick unreinforced masonry slabs and increases the flexural strength of jack arch slabs or roofs. This study examines the bond strength between the clay brick units that make up the jack arch slab and strengthens it using fiber-reinforced polymer rope (FRPR) utilizing a load deflection test. Various parameters were studied, clay brick types affected, span length, camber high and number of injection point (i.e. number of FRPR strengthening are used for each span). The results show the bond strength for jack arch specimens at mid-span for two solid and perforated clay brick slabs gives the most flexural failure. In addition, the increase in the performance of jack arch slabs under line loading (i.e. it is higher deflection) with camber and number of injection.
- 10 November 2022
- Published by Springer Nature in Research Square
Open AccessNew Technique Used for Strengthening Jack Arch Slab
The use of fiber-reinforced polymer rope (FRPR) increases the seismic performance of clay-brick unreinforced masonry slabs and increases the flexural strength of jack arch slabs or roofs. This study examines the bond strength between the clay brick units that make up the jack arch slab and strengthens it using fiber-reinforced polymer rope (FRPR) utilizing a load deflection test. Various parameters were studied, clay brick types affected, span length, camber high and number of injection point (i.e. number of FRPR strengthening are used for each span). The results show the bond strength for jack arch specimens at mid-span for two solid and perforated clay brick slabs gives the most flexural failure. In addition, the increase in the performance of jack arch slabs under line loading (i.e. it is higher deflection) with camber and number of injection.