Marc Kouwenhoven
Marc Kouwenhoven has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Guruprasad Krishnamoorthy
Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications - Joao Tourais
Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
2 shared publications - Arthur H. M. van Roermund
Eindhoven University of Technology
1 shared publication J. Mulder
Electronics Research Laboratory, Delft University of Technology, Mekelweg 4, Delft, 2628 CD, The Netherlands
1 shared publicationJouke Smink
Department MR R&D–Clinical Science Best The Netherlands
1 shared publication- Jouke Smink
Philips Healthcare, 5684 PC Best, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 15 October 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (2) , 1-20
Variable density and anisotropic field-of-view for 3D Stack-of-Stars radial imaging
Objective: To develop a non-iterative method for applying elliptical field-of-view (FOV) to radial imaging and evaluate it for Stack-Of-Stars (SOS) with variable radial density in the $${k}_{z}$$ direction. Materials and methods: New analytic expressions were derived to compute the radial profile angles for an elliptical FOV with and without golden angle sampling. With a major-to-minor-axis FOV ratio of 1:0.5, anisotropic FOV and variable density SOS were evaluated, using point spread function analysis, phantom imaging, and in vivo pelvic imaging. Results: Compared with conventional SOS, elliptical density in $${k}_{z}$$ reduced scan time by 20%, while maintaining similar levels of radial aliasing artifacts. Anisotropic FOV reduced scan time by 31%, resulting in similar levels of radial aliasing artifacts at low undersampling for objects with matching in-plane anisotropy. Combining both techniques resulted in a 45% scan time reduction. Alternatively, when compared to conventional SOS using identical scan time, variable density and anisotropic FOV both displayed a lower level of radial aliasing artifacts, although for anisotropic FOV this effect was less pronounced at higher undersampling. Discussion: Variable density and anisotropic FOV can reduce scan time and/or reduce aliasing artifacts for SOS. The new analytical expressions for elliptical FOV will facilitate future studies on anisotropic FOV radial imaging.- 15 October 2025
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 39 (2) , 1-20
Open AccessVariable density and anisotropic field-of-view for 3D Stack-of-Stars radial imaging
Objective: To develop a non-iterative method for applying elliptical field-of-view (FOV) to radial imaging and evaluate it for Stack-Of-Stars (SOS) with variable radial density in the $${k}_{z}$$ direction. Materials and methods: New analytic expressions were derived to compute the radial profile angles for an elliptical FOV with and without golden angle sampling. With a major-to-minor-axis FOV ratio of 1:0.5, anisotropic FOV and variable density SOS were evaluated, using point spread function analysis, phantom imaging, and in vivo pelvic imaging. Results: Compared with conventional SOS, elliptical density in $${k}_{z}$$ reduced scan time by 20%, while maintaining similar levels of radial aliasing artifacts. Anisotropic FOV reduced scan time by 31%, resulting in similar levels of radial aliasing artifacts at low undersampling for objects with matching in-plane anisotropy. Combining both techniques resulted in a 45% scan time reduction. Alternatively, when compared to conventional SOS using identical scan time, variable density and anisotropic FOV both displayed a lower level of radial aliasing artifacts, although for anisotropic FOV this effect was less pronounced at higher undersampling. Discussion: Variable density and anisotropic FOV can reduce scan time and/or reduce aliasing artifacts for SOS. The new analytical expressions for elliptical FOV will facilitate future studies on anisotropic FOV radial imaging. - Open Access
- 8 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 977-989
Free‐breathing 2D radial cine MRI with respiratory auto‐calibrated motion correction (RAMCO)
Purpose: To develop a free‐breathing (FB) 2D radial balanced steady‐state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto‐calibrated motion correction (RAMCO) based on a motion‐sensing camera.Methods: The signal from a respiratory motion‐sensing camera was recorded during a FB retrospectively electrocardiogram triggered 2D radial balanced steady‐state free precession acquisition using pseudo–tiny‐golden‐angle ordering. With RAMCO, for each acquisition the respiratory signal was retrospectively auto‐calibrated by applying different linear translations, using the resulting in‐plane image sharpness as a criterium. The auto‐calibration determines the optimal magnitude of the linear translations for each of the in‐plane directions to minimize motion blurring caused by bulk respiratory motion. Additionally, motion‐weighted density compensation was applied during radial gridding to minimize through‐plane and non‐bulk motion blurring. Left ventricular functional parameters and sharpness scores of FB radial cine were compared with and without RAMCO, and additionally with conventional breath‐hold Cartesian cine on 9 volunteers.Results: FB radial cine with RAMCO had similar sharpness scores as conventional breath‐hold Cartesian cine and the left ventricular functional parameters agreed. For FB radial cine, RAMCO reduced respiratory motion artifacts with a statistically significant difference in sharpness scores (P < 0.05) compared to reconstructions without motion correction.Conclusion: 2D radial cine imaging with RAMCO allows evaluation of left ventricular functional parameters in FB with 100% respiratory efficiency. It eliminates the need for breath‐holds, which is especially valuable for patients with no or impaired breath‐holding capacity. Validation of the proposed method on patients is warranted.
- 8 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 977-989
Open AccessFree‐breathing 2D radial cine MRI with respiratory auto‐calibrated motion correction (RAMCO)
Purpose: To develop a free‐breathing (FB) 2D radial balanced steady‐state free precession cine cardiac MRI method with 100% respiratory gating efficiency using respiratory auto‐calibrated motion correction (RAMCO) based on a motion‐sensing camera.Methods: The signal from a respiratory motion‐sensing camera was recorded during a FB retrospectively electrocardiogram triggered 2D radial balanced steady‐state free precession acquisition using pseudo–tiny‐golden‐angle ordering. With RAMCO, for each acquisition the respiratory signal was retrospectively auto‐calibrated by applying different linear translations, using the resulting in‐plane image sharpness as a criterium. The auto‐calibration determines the optimal magnitude of the linear translations for each of the in‐plane directions to minimize motion blurring caused by bulk respiratory motion. Additionally, motion‐weighted density compensation was applied during radial gridding to minimize through‐plane and non‐bulk motion blurring. Left ventricular functional parameters and sharpness scores of FB radial cine were compared with and without RAMCO, and additionally with conventional breath‐hold Cartesian cine on 9 volunteers.Results: FB radial cine with RAMCO had similar sharpness scores as conventional breath‐hold Cartesian cine and the left ventricular functional parameters agreed. For FB radial cine, RAMCO reduced respiratory motion artifacts with a statistically significant difference in sharpness scores (P < 0.05) compared to reconstructions without motion correction.Conclusion: 2D radial cine imaging with RAMCO allows evaluation of left ventricular functional parameters in FB with 100% respiratory efficiency. It eliminates the need for breath‐holds, which is especially valuable for patients with no or impaired breath‐holding capacity. Validation of the proposed method on patients is warranted.
- 16 April 1998
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 34 (8) , 705-706
Noise analysis of dynamically nonlinear translinearcircuits
Current noise analysis techniques for translinear and other companding filters are unsuitable for circuits that contain intentional dynamic nonlinearities. The authors present a method for treating dynamic nonlinearities in a straightforward manner using stochastic differential equations.
- 16 April 1998
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 34 (8) , 705-706
Noise analysis of dynamically nonlinear translinearcircuits
Current noise analysis techniques for translinear and other companding filters are unsuitable for circuits that contain intentional dynamic nonlinearities. The authors present a method for treating dynamic nonlinearities in a straightforward manner using stochastic differential equations.