Daria D. Kozhikhina
Research Subjects
Daria D. Kozhikhina has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Yuri Aleksandrovich Vasiliev
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, Moscow, Russia
4 shared publications - Anton Vyacheslavovich Vladzymyrskyy
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, 127051 Moscow, Russia
3 shared publications - Igor M. Shulkin
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies
3 shared publications - Kirill Mikhailovich Arzamasov
МИРЭА - Российский технологический университет, Москва, Россия
3 shared publications - Nikita Dmitrievich Kudryavtsev
Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies of the Moscow Health Care Department, Moscow, Russia
2 shared publications Кожихина Дарья Дмитриевна
Научно-практический клинический центр диагностики и телемедицинских технологий
2 shared publications
Latest Publications
- 6 March 2025
- Published by Media Sphere Publishing Group in Medical Technologies. Assessment and Choice
- No. 1
Compliance with short-team follow-up in BI-RADS 3 patients
Objective. To estimate the incidence of repeated mammography in patients with BI-RADS 3. Material and methods. We analyzed the results of mammography in medical organizations of the Moscow Department of Healthcare providing outpatient medical care for the period from October 1, 2020 to December 31, 2020. The inclusion criterion was BI-RADS 3. Data on repeated mammography performed within 2 years were obtained from electronic medical records. There was no control group. Results. We found 346 mammograms and their text protocols for 346 patients. Repeated mammography was performed in 24.9% (86 out of 346) of patients. The need for repeated mammography was indicated in 34.7% (120 of 346) of protocols. Mean period between baseline and repeated mammography was 327 days. BI-RADS 3 was downgraded to BI-RADS 2 in 81.4% (70 of 86) of cases, increased to BI-RADS 4 in 3.5% of cases (3 of 86) and remained the same in 12.8% of cases (11 of 86). Conclusion. Low rate of repeated mammography indicates the need for strategies to improve mammography adherence, including information technology-based strategies, and additional work with population.
- 6 March 2025
- Published by Media Sphere Publishing Group in Medical Technologies. Assessment and Choice
- No. 1
Compliance with short-team follow-up in BI-RADS 3 patients
Objective. To estimate the incidence of repeated mammography in patients with BI-RADS 3. Material and methods. We analyzed the results of mammography in medical organizations of the Moscow Department of Healthcare providing outpatient medical care for the period from October 1, 2020 to December 31, 2020. The inclusion criterion was BI-RADS 3. Data on repeated mammography performed within 2 years were obtained from electronic medical records. There was no control group. Results. We found 346 mammograms and their text protocols for 346 patients. Repeated mammography was performed in 24.9% (86 out of 346) of patients. The need for repeated mammography was indicated in 34.7% (120 of 346) of protocols. Mean period between baseline and repeated mammography was 327 days. BI-RADS 3 was downgraded to BI-RADS 2 in 81.4% (70 of 86) of cases, increased to BI-RADS 4 in 3.5% of cases (3 of 86) and remained the same in 12.8% of cases (11 of 86). Conclusion. Low rate of repeated mammography indicates the need for strategies to improve mammography adherence, including information technology-based strategies, and additional work with population.
- Open Access
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Effect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- 4 December 2024
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Open AccessEffect of X-ray scan quality on the collective effective dose in patients in telemedicine
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.
- 29 April 2024
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Health Care of the Russian Federation
- Vol. 68 (2) , 102-108
Results of the work of the Reference center for diagnostic radiology with using telemedicine technology
Introduction: the main goal of the Moscow Reference Center (MRC) for Diagnostic Radiology is to optimize study reporting by using teleradiology with a team of highly qualified specialists. Purpose: to evaluate the effectiveness of diagnostic radiology centralization in the capital health care system. Materials and methods. We analyzed the results of telemedicine-based MRC consultations in diagnostic radiology examinations between 08.2020 and 10.2022. Results. The radiologists of MRC reported four million two hundred thousand eighty one study (84.1% first reading, and 15.9% second reading). For the majority of modalities, except for computed tomography (CT), there was a positive correlation between the number of primary descriptions and the number of radiologists. There was a trend towards shorter description times for magnetic resonance imaging (MRI), fluorography, densitometry, and radiography. An audit among MRC employees showed a significantly higher number of fully compliant reports without discrepancies, lower number of general comments, and clinically significant errors compared to the audit of on-site radiologists at medical institutions. Research limitations: no data on (i) anatomical regions of the examinations, (ii) the balance of “normal/pathological” conclusion classes, (iii) the number of examinations with contrast enhancement, making establishing the changes in reporting time impossible. Conclusion. The unification of diagnostic radiology at the MRC has improved report quality and reduced time costs.
- 29 April 2024
- Published by Federal Scientific Center for Hygiene F.F.Erisman in Health Care of the Russian Federation
- Vol. 68 (2) , 102-108
Results of the work of the Reference center for diagnostic radiology with using telemedicine technology
Introduction: the main goal of the Moscow Reference Center (MRC) for Diagnostic Radiology is to optimize study reporting by using teleradiology with a team of highly qualified specialists. Purpose: to evaluate the effectiveness of diagnostic radiology centralization in the capital health care system. Materials and methods. We analyzed the results of telemedicine-based MRC consultations in diagnostic radiology examinations between 08.2020 and 10.2022. Results. The radiologists of MRC reported four million two hundred thousand eighty one study (84.1% first reading, and 15.9% second reading). For the majority of modalities, except for computed tomography (CT), there was a positive correlation between the number of primary descriptions and the number of radiologists. There was a trend towards shorter description times for magnetic resonance imaging (MRI), fluorography, densitometry, and radiography. An audit among MRC employees showed a significantly higher number of fully compliant reports without discrepancies, lower number of general comments, and clinically significant errors compared to the audit of on-site radiologists at medical institutions. Research limitations: no data on (i) anatomical regions of the examinations, (ii) the balance of “normal/pathological” conclusion classes, (iii) the number of examinations with contrast enhancement, making establishing the changes in reporting time impossible. Conclusion. The unification of diagnostic radiology at the MRC has improved report quality and reduced time costs.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Preventive Medicine
- Vol. 27 (5)
The impact of artificial intelligence on double reading of mammograms
Mammography is a gold standard for early diagnosis of breast tumors. Independent double-reading of mammograms by two different radiologists is recommended to use in order to provide a high quality of preventive examination and to detect additional cases of malignant neoplasms. Nevertheless, this approach increases the work load and time of mammography results receiving. OBJECTIVE To assess the impact of artificial intelligence (AI) algorithm on the duration of double reading of mammograms. MATERIAL AND METHODS The study was conducted at the Moscow Reference Centre for Radiology Diagnostics (Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies, telemedai.ru). Mammograms were reviewed and radiology reports were prepared in the Unified Radiological Information Service of the Unified Medical Information and Analytical System in Moscow. Twelve radiologists who specialize in mammogram descriptions participated in the study. Russian-made softwarewas used for automatic analysis of mammograms. Two scenarios were implemented as a part of the study: the first — double-reading by radiologists, the second — first reading by AI algorithm, second reading by radiologist. RESULTS In the first scenario, a double reading was performed for 480 mammograms, in the second one — 510 mammograms. The average duration of the double-reading for the first scenario was 34:12:18 (hh:mm:ss), for the second one — 11:28:58. Application of AI algorithm allowed to reduce the duration of double-reading by 66.4% (p<0.0001). CONCLUSION The use of artificial intelligence algorithm in analysis of preventive mammography examinations allowed to reduce the duration of double-reading and work load on radiologists.
- 23 April 2024
- Published by Media Sphere Publishing Group in Russian Journal of Preventive Medicine
- Vol. 27 (5)
The impact of artificial intelligence on double reading of mammograms
Mammography is a gold standard for early diagnosis of breast tumors. Independent double-reading of mammograms by two different radiologists is recommended to use in order to provide a high quality of preventive examination and to detect additional cases of malignant neoplasms. Nevertheless, this approach increases the work load and time of mammography results receiving. OBJECTIVE To assess the impact of artificial intelligence (AI) algorithm on the duration of double reading of mammograms. MATERIAL AND METHODS The study was conducted at the Moscow Reference Centre for Radiology Diagnostics (Research and Practical Clinical Center for Diagnostics and Telemedicine Technologies, telemedai.ru). Mammograms were reviewed and radiology reports were prepared in the Unified Radiological Information Service of the Unified Medical Information and Analytical System in Moscow. Twelve radiologists who specialize in mammogram descriptions participated in the study. Russian-made softwarewas used for automatic analysis of mammograms. Two scenarios were implemented as a part of the study: the first — double-reading by radiologists, the second — first reading by AI algorithm, second reading by radiologist. RESULTS In the first scenario, a double reading was performed for 480 mammograms, in the second one — 510 mammograms. The average duration of the double-reading for the first scenario was 34:12:18 (hh:mm:ss), for the second one — 11:28:58. Application of AI algorithm allowed to reduce the duration of double-reading by 66.4% (p<0.0001). CONCLUSION The use of artificial intelligence algorithm in analysis of preventive mammography examinations allowed to reduce the duration of double-reading and work load on radiologists.
- Open Access
- 12 July 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (2) , 93-104
Double-reading mammograms using artificial intelligence technologies: A new model of mass preventive examination organization
BACKGROUND: In recent years, the availability of medical datasets and technologies for software development based on artificial intelligence technology has resulted in a growth in the number of solutions for medical diagnostics, particularly mammography. Registered as a medical device, this program can interpret digital mammography, significantly saving time, material, and human resources in healthcare while ensuring the quality of mammary gland preventive studies. AIM: This study aims to justify the possibility and effectiveness of artificial intelligence-based software for the first interpretation of digital mammograms while maintaining the practice of a radiologists second description of X-ray images. MATERIALS AND METHODS: A dataset of 100 digital mammography studies (50 absence of target pathology and 50 ― presence of target pathology, with signs of malignant neoplasms) was processed by software based on artificial intelligence technology that was registered as a medical device in the Russian Federation. Receiver operating characteristic analysis was performed. Limitations of the study include the values of diagnostic accuracy metrics obtained for software based on artificial intelligence technology versions, relevant at the end of 2022. RESULTS: When set to 80.0% sensitivity, artificial intelligence specificity was 90.0% (95% CI, 81.798.3), and accuracy was 85.0% (95% CI, 78.092.0). When set to 100% specificity, artificial intelligence demonstrated 56.0% sensitivity (95% CI, 42.269.8) and 78.0% accuracy (95% CI, 69.986.1). When the sensitivity was set to 100%, the artificial intelligence specificity was 54.0% (95% CI, 40.267.8), and the accuracy was 77.0% (95% CI, 68.885.2). Two approaches have been proposed, providing an autonomous first interpretation of digital mammography using artificial intelligence. The first approach is to evaluate the X-ray image using artificial intelligence with a higher sensitivity than that of the double-reading mammogram by radiologists, with a comparable level of specificity. The second approach implies that artificial intelligence-based software will determine the mammogram category (absence of target pathology or presence of target pathology), indicating the degree of confidence in the obtained result, depending on the corridor into which the predicted value falls. CONCLUSIONS: Both proposed approaches for using artificial intelligence-based software for the autonomous first interpretation of digital mammograms can provide diagnostic quality comparable to, if not superior to, double-image reading by radiologists. The economic benefit from the practical implementation of this approach nationwide can range from 0.6 to 5.5 billion rubles annually.
- 12 July 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (2) , 93-104
Open AccessDouble-reading mammograms using artificial intelligence technologies: A new model of mass preventive examination organization
BACKGROUND: In recent years, the availability of medical datasets and technologies for software development based on artificial intelligence technology has resulted in a growth in the number of solutions for medical diagnostics, particularly mammography. Registered as a medical device, this program can interpret digital mammography, significantly saving time, material, and human resources in healthcare while ensuring the quality of mammary gland preventive studies. AIM: This study aims to justify the possibility and effectiveness of artificial intelligence-based software for the first interpretation of digital mammograms while maintaining the practice of a radiologists second description of X-ray images. MATERIALS AND METHODS: A dataset of 100 digital mammography studies (50 absence of target pathology and 50 ― presence of target pathology, with signs of malignant neoplasms) was processed by software based on artificial intelligence technology that was registered as a medical device in the Russian Federation. Receiver operating characteristic analysis was performed. Limitations of the study include the values of diagnostic accuracy metrics obtained for software based on artificial intelligence technology versions, relevant at the end of 2022. RESULTS: When set to 80.0% sensitivity, artificial intelligence specificity was 90.0% (95% CI, 81.798.3), and accuracy was 85.0% (95% CI, 78.092.0). When set to 100% specificity, artificial intelligence demonstrated 56.0% sensitivity (95% CI, 42.269.8) and 78.0% accuracy (95% CI, 69.986.1). When the sensitivity was set to 100%, the artificial intelligence specificity was 54.0% (95% CI, 40.267.8), and the accuracy was 77.0% (95% CI, 68.885.2). Two approaches have been proposed, providing an autonomous first interpretation of digital mammography using artificial intelligence. The first approach is to evaluate the X-ray image using artificial intelligence with a higher sensitivity than that of the double-reading mammogram by radiologists, with a comparable level of specificity. The second approach implies that artificial intelligence-based software will determine the mammogram category (absence of target pathology or presence of target pathology), indicating the degree of confidence in the obtained result, depending on the corridor into which the predicted value falls. CONCLUSIONS: Both proposed approaches for using artificial intelligence-based software for the autonomous first interpretation of digital mammograms can provide diagnostic quality comparable to, if not superior to, double-image reading by radiologists. The economic benefit from the practical implementation of this approach nationwide can range from 0.6 to 5.5 billion rubles annually.
- 1 January 2022
- Published by Geotar-Media Publishing Group in Healthcare Management: News. Views. Education. Bulletin of VSHOUZ
- Vol. 8 (3)
Speech recognition technology: results of a survey of radiologists at the Moscow reference center for diagnostic radiology
Технология распознавания речи: результаты опроса врачей-рентгенологов Московского референс-центра лучевой диагностики
- 1 January 2022
- Published by Geotar-Media Publishing Group in Healthcare Management: News. Views. Education. Bulletin of VSHOUZ
- Vol. 8 (3)
Speech recognition technology: results of a survey of radiologists at the Moscow reference center for diagnostic radiology
Технология распознавания речи: результаты опроса врачей-рентгенологов Московского референс-центра лучевой диагностики