Effect of X-ray scan quality on the collective effective dose in patients in telemedicine
Authors:
- Zoya A. LantukhZLZoya A. Lantukh
- Daria D. KozhikhinaDKDaria D. Kozhikhina
- Kirill V. TolkachevKTKirill V. Tolkachev
- Maria P. ShatenokMSMaria P. Shatenok
- Ilya V. SoldatovISIlya V. Soldatov
- Uliya V. DruzhininaUDUliya V. Druzhinina
- Yuriy A. VasilevYVYuriy A. Vasilev
- Sergey A. RyzhovSRSergey A. Ryzhov
- Aleksandr V. VodovatovAVAleksandr V. Vodovatov
- Лантух Зоя АлександровнаЛАЛантух Зоя Александровна
Open Access
- 4 December 2024
- journal article
- Published by ECO-Vector LLC (Publications) in Digital Diagnostics
- Vol. 5 (3) , 491-504
Abstract
BACKGROUND: The key objective of a healthcare provider is to ensure the quality and increase the efficiency of X-ray diagnostics in both municipal and private medical facilities. A poor-quality radiologic image requires repeated procedures, which results in further reputation, time, and economic losses for the medical organization. Moreover, repeated examinations further contribute to the patient’s total radiation exposure. AIM: To assess the contribution of poor-quality X-ray examinations to patient exposure in outpatient medical organizations with telemedicine services. MATERIALS AND METHODS: This study aimed to evaluate poor-quality X-ray examinations recorded by radiologists at the Moscow Reference Center in 2022 by applying a specially developed quality control system for diagnostic examinations based on information technology. In addition, during X-ray examinations, the methods for finding effective doses received by patients were applied in compliance with current regulatory requirements. Statistical methods were also used. RESULTS: In this study, 2,059 poor-quality examinations were recorded, accounting for 0.084% of the total number of examinations interpreted with telemedicine. The collective effective dose from poor-quality examinations was 3.613 man-Sv, which was 0.11% of the total collective dose of patients in outpatient medical organizations. CONCLUSION: The implementation of a quality control system for diagnostic examinations based on information technology proved to be efficient for medical organizations rendering telemedicine services.Keywords
This publication has 11 references indexed in Scilit:
- The use of artificial intelligence technologies as a way to ensure the quality of chest radiography.2023
- Patient dose monitoring software in radiologyDigital Diagnostics, 2022
- Perspective approaches to classification of radiation accidents in radiology on the example of computed tomographyAIP Conference Proceedings, 2021
- Reject rate analysis in digital radiography: an Australian emergency imaging department case studyJournal of Medical Radiation Sciences, 2019
- How to manage accidental and unintended exposure in radiology: an ESR white paperInsights into Imaging, 2019
- Fundamentals of Medical Imaging Management2019
- Educational Module Intervention for Radiographers to Reduce Repetition Rate of Routine Digital Chest Radiography in Makkah Region of Saudi Arabia Tertiary Hospitals: Protocol of a Quasi-Experimental StudyJMIR Research Protocols, 2017
- Unintended and accidental medical radiation exposures in radiology: guidelines on investigation and preventionJournal of Radiological Protection, 2017
- Digital Repeat Analysis; Setup and OperationJournal of Digital Imaging, 2006