CXChengze Xue

Chengze Xue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengze Xue has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Qiaoling Du

    College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Road, Changchun, Jilin 130012, China

    3 shared publications
  • Jiaqi Zhao

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China

    1 shared publication
  • Sinan Liu

    United Automotive Electronic Systems Company, Shanghai, China

    1 shared publication
  • Tianhe Zhang

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China

    1 shared publication
  • Wenli Ma

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, China

    1 shared publication
  • Yankai Wang

    State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China

    1 shared publication

Latest Publications

  • Open Access

    Research on Motion Control of Bionic Sucker Inchworm Robot Based on MPC

    by Chengze Xue, Qiaoling Du, Wenli Ma, Yinfeng Geng

    Inchworm robots are typical insect bionic robots that are able to move in narrow space such as pipelines, which expand the range of robot application. In this paper, the motion control method of the bionic sucker inchworm robot (BSIR) based on MPC is proposed, which enables the inchworm robot to achieve "Ω" motion gait and steering gait on vertical and horizontal planes of different materials. Firstly, the negative pressure suction cup imitating octopus tentacles (NPSC-IOT) is designed and the sucker control model is proposed. Under negative pressure control, the adsorption pressure of the sucker is adjusted to satisfy the needs of the trunk structure movement. Secondly, the bionic sucker controller based on MPC is designed, and the closed-loop control is realized by using the data feedback from the air pressure sensor. Thirdly, BSIR with installed NPSC-IOT as the robot’s tentacles is developed. Finally, the experiment verifies the feasibility of the bionic sucker controller based on MPC to control BSIR to achieve ’ Ω ’ motion gait and steering gait on vertical and horizontal planes of different materials. The experimental results show that BSIR is able to achieve "Ω" gait and turning gait on vertical and horizontal surfaces of glass, tiles, white gray walls, and metal.


  • A Total Transmitted Light Intensity Method for Detecting Concentration of Glucose Aqueous Solution Directly Irradiated by Near Infrared LED

    by Jiaqi Zhao, Qiaoling Du, Sinan Liu, Chengze Xue

    Glucose plays an important role in biological fermentation and biosensing. Therefore, it is very important to detect the concentration of glucose aqueous solution quickly and accurately. A novel method for detecting the concentration of glucose solution is introduced in this paper. Based on the spectral characteristics of near-infrared light-emitting diode (NIR LED), the total transmitted light intensity (TTLI) - concentration model of glucose solution directly irradiated by NIR LED was established to detect the concentration of glucose solution. In this model, firstly, TTLI of glucose solution and TTLI of deionized water were defined. Secondly, the definition formula of the change ratio of TTLI was provided. Finally, the linear relationship between the change ratio of TTLI and the concentration of glucose solution was derived. In order to verify the effectiveness of TTLI method, NIR LED Glucose Solution Concentration Detection System (NIR LED - GSCDS) was designed. In this system, an alternating measurement method is designed to reduce the influence of the radiation fluctuation of NIR LED light source on the accuracy of detection results, and the thermostatic circulation subsystem is designed to reduce the influence of the change of solution temperature on the infrared light absorption rate of glucose solution. The experimental results show that the linear correlation coefficient between the change rate of total transmitted light intensity and glucose solution concentration is 0.998 and the relative uncertainty is 8.2% in the concentration range of 1000 mg/dL ~ 5000 mg/dL. Therefore, TTLI method can determine the concentration of glucose solution under the direct irradiation of NIR LED light source without complex spectroscopic system.


  • Open Access

    The WL_PCR: A Planning for Ground-to-Pole Transition of Wheeled-Legged Pole-Climbing Robots

    by Yankai Wang, Qiaoling Du, Tianhe Zhang, Chengze Xue

    Hybrid mobile robots with two motion modes of a wheeled vehicle and truss structure with the ability to climb poles have significant flexibility. The motion planning of this kind of robot on a pole has been widely studied, but few studies have focused on the transition of the robot from the ground to the pole. In this study, a locomotion strategy of wheeled-legged pole-climbing robots (the WL_PCR) is proposed to solve the problem of ground-to-pole transition. By analyzing the force of static and dynamic process in the ground-to-pole transition, the condition of torque provided by the gripper and moving joint is proposed. The mathematical expression of Centre of Mass (CoM) of the wheeled-legged pole-climbing robots is utilized, and the conditions for the robot to smoothly transition from the ground to the vertical pole are proposed. Finally, the feasibility of this method is proved by the simulation and experimentation of a locomotion strategy on wheeled-legged pole-climbing robots.