A Total Transmitted Light Intensity Method for Detecting Concentration of Glucose Aqueous Solution Directly Irradiated by Near Infrared LED
- 16 November 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Abstract
Glucose plays an important role in biological fermentation and biosensing. Therefore, it is very important to detect the concentration of glucose aqueous solution quickly and accurately. A novel method for detecting the concentration of glucose solution is introduced in this paper. Based on the spectral characteristics of near-infrared light-emitting diode (NIR LED), the total transmitted light intensity (TTLI) - concentration model of glucose solution directly irradiated by NIR LED was established to detect the concentration of glucose solution. In this model, firstly, TTLI of glucose solution and TTLI of deionized water were defined. Secondly, the definition formula of the change ratio of TTLI was provided. Finally, the linear relationship between the change ratio of TTLI and the concentration of glucose solution was derived. In order to verify the effectiveness of TTLI method, NIR LED Glucose Solution Concentration Detection System (NIR LED - GSCDS) was designed. In this system, an alternating measurement method is designed to reduce the influence of the radiation fluctuation of NIR LED light source on the accuracy of detection results, and the thermostatic circulation subsystem is designed to reduce the influence of the change of solution temperature on the infrared light absorption rate of glucose solution. The experimental results show that the linear correlation coefficient between the change rate of total transmitted light intensity and glucose solution concentration is 0.998 and the relative uncertainty is 8.2% in the concentration range of 1000 mg/dL ~ 5000 mg/dL. Therefore, TTLI method can determine the concentration of glucose solution under the direct irradiation of NIR LED light source without complex spectroscopic system.Keywords
Funding Information
- Jilin province science and technology development plan project (20190303008SF)
This publication has 18 references indexed in Scilit:
- The effects of pulsed laser parameters on the photoacoustic detection of glucose aqueous solution2017
- Development of a biosensor telemetry system for monitoring fermentation in craft breweriesFood Chemistry, 2016
- Exploration and Practice in Photoacoustic Measurement for Glucose Concentration Based on Tunable Pulsed Laser Induced UltrasoundInternational Journal of Optomechatronics, 2015
- Near-Infrared Studies of Glucose and Sucrose in Aqueous Solutions: Water Displacement Effect and Red Shift in Water Absorption from Water-Solute InteractionApplied Spectroscopy, 2013
- Uncertainty in the Determination of Glucose and Sucrose in Solutions with Chitosan by Enzymatic MethodsJournal of the Brazilian Chemical Society, 2013
- A Reference-Wavelength-Based Method for Improved Analysis of Near-Infrared SpectroscopyApplied Spectroscopy, 2009
- Measuring glucose concentration by Raman spectroscopy using liquid core optical fibersProceedings of SPIE, 2004
- Temperature-Insensitive Measurement of Glucose Concentration Based on Near Infrared Spectroscopy and Partial Least Squares AnalysisOptical Review, 2003
- Near-Infrared Transmission Spectroscopy of Aqueous Solutions: Influence of Optical Pathlength on Signal-To-Noise RatioApplied Spectroscopy, 2002
- Analysis of metabolites in aqueous solutions by using laser Raman spectroscopyApplied Optics, 1993