Ilya V. Malyshev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ilya V. Malyshev has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Alexey Evgenievich Pestov
Institute for Physics of Microstructures of the Russian Academy of Sciences
7 shared publications - Mikhail N. Toropov
Институт физики микроструктур Российской академии наук, Нижний Новгород, Россия
5 shared publications - Dmitriy G. Reunov
Institute of Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
3 shared publications Nikolay Chkhalo
Institute for Physics of Microstructures of the Russian Academy of Sciences
3 shared publications- Nikolay I. Chkhalo
Institute for Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
3 shared publications Н.и. Чхало
Институт физики микроструктур Российской академии наук, Нижний Новгород, Россия
3 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by MDPI AG in Tomography
- Vol. 12 (3) , 41
Axial X-Ray Microscopy in Nanotomography
Background/Objectives: This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy. Methods: By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells. Results: The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50–100 nm organelles were detected. Conclusions: Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.
- 18 March 2026
- Published by MDPI AG in Tomography
- Vol. 12 (3) , 41
Open AccessAxial X-Ray Microscopy in Nanotomography
Background/Objectives: This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy. Methods: By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells. Results: The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50–100 nm organelles were detected. Conclusions: Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.
- 23 January 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (4) , 837-844
Technique for forming substrates for grazing incidence X-ray mirrors with cylindrical surface profiles
The paper demonstrates the possibility of forming flat substrates for grazing incidence X-ray mirrors with an accuracy of RMS ∼0.7nm, and also implements a technique for manufacturing grazing incidence X-ray optical elements with cylindrical surface profiles, using ion beam etching. The technique assumes the linear movement of the workpiece behind a slit diaphragm with a speed that varies depending on the coordinate. The result of the work was the creation of a pair of X-ray mirror substrates for a Kirkpatrick-Baez collimating system, having surface shape deviations from the ideal plane of HM1=1.05µm and HM2=1.13µm, and from the calculated parabolic cylinders of RMSM1=3.0nm and RMSM2=2.9nm. The described technique makes it possible to produce substrates for mirrors in the form of elliptical and parabolic cylinders used in commercial diffractometers, synchrotrons, and free electron lasers for collimation and focusing of X-ray radiation, as well as in the telescopes of space observatories.
- 23 January 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (4) , 837-844
Technique for forming substrates for grazing incidence X-ray mirrors with cylindrical surface profiles
The paper demonstrates the possibility of forming flat substrates for grazing incidence X-ray mirrors with an accuracy of RMS ∼0.7nm, and also implements a technique for manufacturing grazing incidence X-ray optical elements with cylindrical surface profiles, using ion beam etching. The technique assumes the linear movement of the workpiece behind a slit diaphragm with a speed that varies depending on the coordinate. The result of the work was the creation of a pair of X-ray mirror substrates for a Kirkpatrick-Baez collimating system, having surface shape deviations from the ideal plane of HM1=1.05µm and HM2=1.13µm, and from the calculated parabolic cylinders of RMSM1=3.0nm and RMSM2=2.9nm. The described technique makes it possible to produce substrates for mirrors in the form of elliptical and parabolic cylinders used in commercial diffractometers, synchrotrons, and free electron lasers for collimation and focusing of X-ray radiation, as well as in the telescopes of space observatories.
- Open Access
- 6 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1179-1188
The diamond–silicon carbide composite Skeleton® as a promising material for substrates of intense X-ray beam optics
The paper considers the possibility of using the diamond-silicon carbide composite Skeleton® with a technological coating of polycrystalline silicon as a substrate for X-ray mirrors used with powerful synchrotron radiation sources (third+ and fourth generation). Samples were studied after polishing to provide the following surface parameters: root-mean-square flatness ≃ 50 nm, micro-roughness on the frame 2 µm × 2 µm σ ≃ 0.15 nm. The heat capacity, thermal conductivity and coefficient of linear thermal expansion were investigated. For comparison, a monocrystalline silicon sample was studied under the same conditions using the same methods. The value of the coefficient of linear thermal expansion turned out to be higher than that of monocrystalline silicon and amounted to 4.3 × 10−6 K−1, and the values of thermal conductivity (5.0 W cm−1 K−1) and heat capacity (1.2 J K−1 g−1) also exceeded the values for Si. Thermally induced deformations of both Skeleton® and monocrystalline silicon samples under irradiation with a CO2 laser beam have also been experimentally studied. Taking into account the obtained thermophysical constants, the calculation of thermally induced deformation under irradiation with hard (20 keV) X-rays showed almost three times less deformation of the Skeleton® sample than of the monocrystalline silicon sample.
- 6 August 2024
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 31 (5) , 1179-1188
Open AccessThe diamond–silicon carbide composite Skeleton® as a promising material for substrates of intense X-ray beam optics
The paper considers the possibility of using the diamond-silicon carbide composite Skeleton® with a technological coating of polycrystalline silicon as a substrate for X-ray mirrors used with powerful synchrotron radiation sources (third+ and fourth generation). Samples were studied after polishing to provide the following surface parameters: root-mean-square flatness ≃ 50 nm, micro-roughness on the frame 2 µm × 2 µm σ ≃ 0.15 nm. The heat capacity, thermal conductivity and coefficient of linear thermal expansion were investigated. For comparison, a monocrystalline silicon sample was studied under the same conditions using the same methods. The value of the coefficient of linear thermal expansion turned out to be higher than that of monocrystalline silicon and amounted to 4.3 × 10−6 K−1, and the values of thermal conductivity (5.0 W cm−1 K−1) and heat capacity (1.2 J K−1 g−1) also exceeded the values for Si. Thermally induced deformations of both Skeleton® and monocrystalline silicon samples under irradiation with a CO2 laser beam have also been experimentally studied. Taking into account the obtained thermophysical constants, the calculation of thermally induced deformation under irradiation with hard (20 keV) X-rays showed almost three times less deformation of the Skeleton® sample than of the monocrystalline silicon sample.
- 1 June 2024
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 69 (6) , 1555-1567
The Theory of Axial Tomography Based on the Inverse Radon Transform for High-Aperture Soft X-ray Microscopy
For soft X-ray microscopy in the approximation of geometrical optics, a theoretical model for the formation of the received image is constructed – a relationship is found between the image recorded on the detector and the 3D distribution of the sample absorption index using a high-aperture mirror objective (NA ¿ 0.3) with a focus depth close to the diffraction limit. The solution of the inverse problem of tomography for determining this 3D distribution from the data of measurements in a high-aperture mirror SXR-microscope is obtained.
- 1 June 2024
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 69 (6) , 1555-1567
The Theory of Axial Tomography Based on the Inverse Radon Transform for High-Aperture Soft X-ray Microscopy
For soft X-ray microscopy in the approximation of geometrical optics, a theoretical model for the formation of the received image is constructed – a relationship is found between the image recorded on the detector and the 3D distribution of the sample absorption index using a high-aperture mirror objective (NA ¿ 0.3) with a focus depth close to the diffraction limit. The solution of the inverse problem of tomography for determining this 3D distribution from the data of measurements in a high-aperture mirror SXR-microscope is obtained.
- Open Access
- 18 December 2023
- Published by Acta Naturae Ltd in Acta Naturae
- Vol. 15 (4) , 32-43
Soft X-ray Microscopy in Cell Biology: Current Status, Contributions and Prospects
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.
- 18 December 2023
- Published by Acta Naturae Ltd in Acta Naturae
- Vol. 15 (4) , 32-43
Open AccessSoft X-ray Microscopy in Cell Biology: Current Status, Contributions and Prospects
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.
- 26 October 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (31) , 8462-8471
EUV telescope for a Cubesat nanosatellite
This paper describes in detail a compact (2U format) telescope operating in the extreme ultraviolet range for studying the solar corona at a wavelength of 17.14 nm. The telescope objective has been built according to the Ritchey–Chrétien scheme with the following parameters: effective focal length of 381.3 mm, field of view of 2×2∘, and angular resolution of 11 in. Reflective multilayer Al/Be coatings were used, having 55% reflectance and a 0.4 nm spectral bandwidth. The wavefront rms error is 30 nm. An interferometric technique for controlling the shapes of the substrates and for adjusting the optical system and detector of the telescope assembly is described in detail.
- 26 October 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (31) , 8462-8471
EUV telescope for a Cubesat nanosatellite
This paper describes in detail a compact (2U format) telescope operating in the extreme ultraviolet range for studying the solar corona at a wavelength of 17.14 nm. The telescope objective has been built according to the Ritchey–Chrétien scheme with the following parameters: effective focal length of 381.3 mm, field of view of 2×2∘, and angular resolution of 11 in. Reflective multilayer Al/Be coatings were used, having 55% reflectance and a 0.4 nm spectral bandwidth. The wavefront rms error is 30 nm. An interferometric technique for controlling the shapes of the substrates and for adjusting the optical system and detector of the telescope assembly is described in detail.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 867
Теория аксиальной томографии на основе обратного преобразования Радона для высокоапертурной мягкой рентгеновской микроскопии
For soft X-ray microscopy in the approximation of geometrical optics, a theoretical model for the formation of the received image is constructed - a relationship is found between the image recorded on the detector and the 3D distribution of the sample absorption index using a high-aperture mirror objective (NA>0.3) with a focus depth close to the diffraction limit. The solution of the inverse problem of tomography for determining this 3D distribution from the data of measurements in a high-aperture mirror SXR-microscope is obtained.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 867
Теория аксиальной томографии на основе обратного преобразования Радона для высокоапертурной мягкой рентгеновской микроскопии
For soft X-ray microscopy in the approximation of geometrical optics, a theoretical model for the formation of the received image is constructed - a relationship is found between the image recorded on the detector and the 3D distribution of the sample absorption index using a high-aperture mirror objective (NA>0.3) with a focus depth close to the diffraction limit. The solution of the inverse problem of tomography for determining this 3D distribution from the data of measurements in a high-aperture mirror SXR-microscope is obtained.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 963
Внеосевой асферический коллектор для экстремальной ультрафиолетовой литографии и мягкой рентгеновской микроскопии
By the method of ion-beam shape correction, a small-sized ion beam formed a non–axisymmetric aspherical profile of the collector surface for an extreme ultraviolet radiation source TEUS-S100 with a numerical aperture of NA= 0.25, PV on the surface is 36.3 microns, the surface shape accuracy by standard deviation is 0.074 microns, which allowed to obtain a focusing spot with a width of 300 microns at half-height. To solve the problem, the technological ion source KLAN-53M was upgraded – the flat ion-optical system was replaced with a focusing one. The ion-optical system consisting of a pair of concave grids with a radius of curvature of 60 mm provided the following parameters of the ion beam: the ion current is 20 mA, the width at half–height is 8.2 mm at a distance of 66 mm from the cutoff of the ion source.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 963
Внеосевой асферический коллектор для экстремальной ультрафиолетовой литографии и мягкой рентгеновской микроскопии
By the method of ion-beam shape correction, a small-sized ion beam formed a non–axisymmetric aspherical profile of the collector surface for an extreme ultraviolet radiation source TEUS-S100 with a numerical aperture of NA= 0.25, PV on the surface is 36.3 microns, the surface shape accuracy by standard deviation is 0.074 microns, which allowed to obtain a focusing spot with a width of 300 microns at half-height. To solve the problem, the technological ion source KLAN-53M was upgraded – the flat ion-optical system was replaced with a focusing one. The ion-optical system consisting of a pair of concave grids with a radius of curvature of 60 mm provided the following parameters of the ion beam: the ion current is 20 mA, the width at half–height is 8.2 mm at a distance of 66 mm from the cutoff of the ion source.
- 14 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47567-47586
High-aperture EUV microscope using multilayer mirrors and a 3D reconstruction algorithm based on z-tomography
The article is devoted to the development of an EUV microscope using a wavelength of 13.84 nm. Due to the use of a mirror lens with a large numerical aperture, NA = 0.27, and a short depth of focus, it has been possible to carry out z-tomography of bio-samples for the first time with this type of microscope. A 3D image was reconstructed, and a pixel resolution of 140 nm was obtained. A new simple algorithm for the 3D reconstruction of absorption images from z-tomography data has been proposed that takes into account lens aberrations and a point spread function. The algorithm reduces the inverse absorption task to the corresponding well-studied task of fluorescence microscopy, with an error of 10% for cells up to 10 µm thick.
- 14 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47567-47586
High-aperture EUV microscope using multilayer mirrors and a 3D reconstruction algorithm based on z-tomography
The article is devoted to the development of an EUV microscope using a wavelength of 13.84 nm. Due to the use of a mirror lens with a large numerical aperture, NA = 0.27, and a short depth of focus, it has been possible to carry out z-tomography of bio-samples for the first time with this type of microscope. A 3D image was reconstructed, and a pixel resolution of 140 nm was obtained. A new simple algorithm for the 3D reconstruction of absorption images from z-tomography data has been proposed that takes into account lens aberrations and a point spread function. The algorithm reduces the inverse absorption task to the corresponding well-studied task of fluorescence microscopy, with an error of 10% for cells up to 10 µm thick.