Dmitriy G. Reunov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dmitriy G. Reunov has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
N. I. Chkhalo
Institute of Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
6 shared publicationsI. V. Malyshev
Institute of Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
5 shared publications- Ilya V. Malyshev
Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, Russia
3 shared publications A. A. Perekalov
Institute of Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
2 shared publicationsA. N. Nechay
Institute of Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
2 shared publications- Alexey Evgenievich Pestov
Institute for Physics of Microstructures of the Russian Academy of Sciences
2 shared publications
Latest Publications
- Open Access
- 18 March 2026
- Published by MDPI AG in Tomography
- Vol. 12 (3) , 41
Axial X-Ray Microscopy in Nanotomography
Background/Objectives: This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy. Methods: By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells. Results: The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50–100 nm organelles were detected. Conclusions: Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.
- 18 March 2026
- Published by MDPI AG in Tomography
- Vol. 12 (3) , 41
Open AccessAxial X-Ray Microscopy in Nanotomography
Background/Objectives: This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy. Methods: By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells. Results: The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50–100 nm organelles were detected. Conclusions: Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.
- 14 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105415
Microscope for investigating the size of an EUV radiation source emitting at 11.2 nm
In this article, we report on the development, construction and operation of a microscope to study the emission radiation of laser plasma in the EUV spectral range. The main optical unit of the microscope is a two-mirror spherical Schwarzschild objective with a 5x magnification. The microscope builds an image of the plasma cloud at a wavelength of 11.25 nm. This wavelength is determined by the manufactured multilayer x-ray mirrors based on a Mo/Be structure. To suppress the long-wave noise component of the signal in the VUV, UV, visible and IR spectral range, we used two thin-film Mo/Be filters. The device was calibrated on the basis of both EUV radiation registration efficiency and spatial resolution at the operating wavelength, these being 12% and 3.9 μm, respectively. We also discuss the results of studying the size of a laser spark in gas-jet targets.
- 14 October 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (10) , 105415
Microscope for investigating the size of an EUV radiation source emitting at 11.2 nm
In this article, we report on the development, construction and operation of a microscope to study the emission radiation of laser plasma in the EUV spectral range. The main optical unit of the microscope is a two-mirror spherical Schwarzschild objective with a 5x magnification. The microscope builds an image of the plasma cloud at a wavelength of 11.25 nm. This wavelength is determined by the manufactured multilayer x-ray mirrors based on a Mo/Be structure. To suppress the long-wave noise component of the signal in the VUV, UV, visible and IR spectral range, we used two thin-film Mo/Be filters. The device was calibrated on the basis of both EUV radiation registration efficiency and spatial resolution at the operating wavelength, these being 12% and 3.9 μm, respectively. We also discuss the results of studying the size of a laser spark in gas-jet targets.
- 1 December 2024
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 18 (S1) , S38-S44
Stand for Certification of X-ray Optical Elements and Systems for Synchrotron Applications
The article describes an X-ray optical certification setup based on a microfocus X-ray tube, a Kirkpatrick-Baez (KB) collimating system, and a Gpixel2020BSI matrix semiconductor detector. To minimize X-ray beam scattering and intensity loss due to absorption in air, vacuum-tight tubes with compton windows are installed between the microfocus X-ray tube and the KB system, and between the KB system and the detector. Pumping is performed by an oil-free fore-vacuum pump. The setup that has been developed allows for studying the X-ray optical scheme of two-mirror monochromators to determine the deformation of the beam wave front at their outputs, and to calibrate the movement of high-precision mechanical tables. The setup also allows for studying the focusing properties of the Kirkpatrick-Baez system, itself, namely, measuring the size of the focus spot and calibrating the piezo-drives of the mirrors. As a result of adjusting the collimating system, we obtained a converging beam, but this did not prevent us from measuring the wave front broadening upon reflection from the substrates for a two-mirror monochromator. Two substrates made of single-crystal silicon Si(100) were studied. It was shown that upon reflection from the substrate after chemical-mechanical polishing (CMP) only, the reflected beam, due to mirror shape errors, broadened by 18 μm, while after chemical-mechanical polishing and correction of local shape errors using an ion beam, the broadening was reduced to 11 μm, which corresponds to an angular error of the mirror at a level of 3 μrad. This is 7 times less than the angular divergence of the beam at the output of the collimating system, due to the size of the radiation source.
- 1 December 2024
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 18 (S1) , S38-S44
Stand for Certification of X-ray Optical Elements and Systems for Synchrotron Applications
The article describes an X-ray optical certification setup based on a microfocus X-ray tube, a Kirkpatrick-Baez (KB) collimating system, and a Gpixel2020BSI matrix semiconductor detector. To minimize X-ray beam scattering and intensity loss due to absorption in air, vacuum-tight tubes with compton windows are installed between the microfocus X-ray tube and the KB system, and between the KB system and the detector. Pumping is performed by an oil-free fore-vacuum pump. The setup that has been developed allows for studying the X-ray optical scheme of two-mirror monochromators to determine the deformation of the beam wave front at their outputs, and to calibrate the movement of high-precision mechanical tables. The setup also allows for studying the focusing properties of the Kirkpatrick-Baez system, itself, namely, measuring the size of the focus spot and calibrating the piezo-drives of the mirrors. As a result of adjusting the collimating system, we obtained a converging beam, but this did not prevent us from measuring the wave front broadening upon reflection from the substrates for a two-mirror monochromator. Two substrates made of single-crystal silicon Si(100) were studied. It was shown that upon reflection from the substrate after chemical-mechanical polishing (CMP) only, the reflected beam, due to mirror shape errors, broadened by 18 μm, while after chemical-mechanical polishing and correction of local shape errors using an ion beam, the broadening was reduced to 11 μm, which corresponds to an angular error of the mirror at a level of 3 μrad. This is 7 times less than the angular divergence of the beam at the output of the collimating system, due to the size of the radiation source.
- 1 July 2024
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 69 (7) , 2098-2102
Substrates for Soft X-Ray Microscopy Based on Si3N4 Membranes
Silicon nitride membranes were experimentally obtained as substrates for biological samples, which are examined using a microscope with an operating wavelength of 13.8 nm. The free-hanging films obtained have a size of up to 1.5 × 1.5 mm2, which makes it possible to select an area of interest for investigation on the sample on the order of tens to hundreds of microns. The mechanical strength of the membranes satisfies that the samples do not tear the membranes and withstand transportation. The results obtained are an import-substituting technology for the manufacture of Si3N4 membranes. The resulting membranes have a transparency of more than 40% in the range of the “water transparency window” (2.3–4.4 nm) and EUV (13–15 nm). The developed technology will become the basis for creating cuvettes for living biological samples for soft X-ray microscopy studies.
- 1 July 2024
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 69 (7) , 2098-2102
Substrates for Soft X-Ray Microscopy Based on Si3N4 Membranes
Silicon nitride membranes were experimentally obtained as substrates for biological samples, which are examined using a microscope with an operating wavelength of 13.8 nm. The free-hanging films obtained have a size of up to 1.5 × 1.5 mm2, which makes it possible to select an area of interest for investigation on the sample on the order of tens to hundreds of microns. The mechanical strength of the membranes satisfies that the samples do not tear the membranes and withstand transportation. The results obtained are an import-substituting technology for the manufacture of Si3N4 membranes. The resulting membranes have a transparency of more than 40% in the range of the “water transparency window” (2.3–4.4 nm) and EUV (13–15 nm). The developed technology will become the basis for creating cuvettes for living biological samples for soft X-ray microscopy studies.
- 7 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 57 (4) , 925-930
Observation of quasi-Bragg scattering by Goebel mirrors
This paper reports the first observation of quasi-Bragg scattering from collimating Goebel mirrors in a real instrument. On the basis of the experimental data obtained and the numerical analysis performed, it is concluded that it is necessary to take into account the effect of quasi-Bragg scattering when constructing real devices with multilayer mirrors for use in X-ray diffractometry and in spectroscopy, especially for small-angle scattering with position-sensitive detectors.
- 7 June 2024
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 57 (4) , 925-930
Observation of quasi-Bragg scattering by Goebel mirrors
This paper reports the first observation of quasi-Bragg scattering from collimating Goebel mirrors in a real instrument. On the basis of the experimental data obtained and the numerical analysis performed, it is concluded that it is necessary to take into account the effect of quasi-Bragg scattering when constructing real devices with multilayer mirrors for use in X-ray diffractometry and in spectroscopy, especially for small-angle scattering with position-sensitive detectors.
- Open Access
- 18 December 2023
- Published by Acta Naturae Ltd in Acta Naturae
- Vol. 15 (4) , 32-43
Soft X-ray Microscopy in Cell Biology: Current Status, Contributions and Prospects
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.
- 18 December 2023
- Published by Acta Naturae Ltd in Acta Naturae
- Vol. 15 (4) , 32-43
Open AccessSoft X-ray Microscopy in Cell Biology: Current Status, Contributions and Prospects
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.
- 17 August 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (4) , 859-864
Determining the Size of the EUV Laser-Plasma Source for a Microscope
In this paper, the size and intensity of laser-plasma sources based on pulsed argon gas jets operating at a wavelength of 13.84 nm are studied. The gas jet is excited by laser radiation at a wavelength of 1064 nm with a pulse duration of 4.4 ns, a repetition frequency of 10 Hz, and a pulse energy of 0.5 J. Two methods are used to form the jet of a pulsed gas target: using a jet with a supersonic nozzle and using a capillary. The capillary source is commercially available. The sources are certified using a mirror microscope operating in the extreme ultraviolet region at a wavelength of 13.84 nm. Due to the possibility of supplying a higher pressure of the operating gas to the nozzle inlet, increasing the density, and reducing the exit angle of the gas jet in the supersonic nozzle compared to the capillary, the peak radiation intensity at a wavelength of 13.84 nm is found to increase six times. The width at half maximum of the injector-based source diameter is 250 ± 10 μm with a profile close to Gaussian. In the field of view of a microscope of 25 × 25 μm, the nonuniformity of illumination from the “source on the injector” is ~1%, and in the field of view of 50 × 50 μm, it is ~4%. The width at half maximum of the source diameter based on a commercial valve with a capillary source is 330 ± 10 µm with a profile close to U-shaped. Based on the results of the comparison, an upgraded version of the microscope with up to 350× magnification will use an injector-based source.
- 17 August 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (4) , 859-864
Determining the Size of the EUV Laser-Plasma Source for a Microscope
In this paper, the size and intensity of laser-plasma sources based on pulsed argon gas jets operating at a wavelength of 13.84 nm are studied. The gas jet is excited by laser radiation at a wavelength of 1064 nm with a pulse duration of 4.4 ns, a repetition frequency of 10 Hz, and a pulse energy of 0.5 J. Two methods are used to form the jet of a pulsed gas target: using a jet with a supersonic nozzle and using a capillary. The capillary source is commercially available. The sources are certified using a mirror microscope operating in the extreme ultraviolet region at a wavelength of 13.84 nm. Due to the possibility of supplying a higher pressure of the operating gas to the nozzle inlet, increasing the density, and reducing the exit angle of the gas jet in the supersonic nozzle compared to the capillary, the peak radiation intensity at a wavelength of 13.84 nm is found to increase six times. The width at half maximum of the injector-based source diameter is 250 ± 10 μm with a profile close to Gaussian. In the field of view of a microscope of 25 × 25 μm, the nonuniformity of illumination from the “source on the injector” is ~1%, and in the field of view of 50 × 50 μm, it is ~4%. The width at half maximum of the source diameter based on a commercial valve with a capillary source is 330 ± 10 µm with a profile close to U-shaped. Based on the results of the comparison, an upgraded version of the microscope with up to 350× magnification will use an injector-based source.
- 1 August 2023
- Published by The Russian Academy of Sciences in Poverhnostʹ. Rentgenovskie, sinhrotronnye i nejtronnye issledovaniâ
- No. 8,p. 16-21
Sizing the EUV Laser-Plasma Source for a Microscope
The size and intensity of laser-plasma sources based on pulsed argon gas jets operating at a wavelength of 13.84 nm were studied. The gas jet was excited by laser radiation at a wavelength of 1064 nm with a pulse duration of 4.4 ns, a repetition frequency of 10 Hz, and a pulse energy of 0.5 J. Two methods of forming a jet of a pulsed gas target were studied: using a jet with a supersonic nozzle and using a capillary. The capillary source is commercially available. The sources were certified using a mirror microscope operating in the extreme ultraviolet region at a wavelength of 13.84 nm. It was found that due to the possibility of supplying a higher pressure of the working gas to the nozzle inlet, increasing the density and reducing the exit angle of the gas jet in the supersonic nozzle compared to the capillary, the peak radiation intensity at a wavelength of 13.84 nm increased six times. The full width at half maximum of the nozzle-based source diameter was 250 ± 10 μm with a profile close to Gaussian. In the field of view of a microscope of 25 × 25 μm, the nonuniformity of illumination from the “source on the nozzle” is about 1%; in the field of view of 50 × 50 μm, it is about 4%. The full width at half maximum of the source diameter based on a commercial valve with a capillary source was 330 ± 10 µm with a profile close to П-shaped. Based on the results of the comparison, an upgraded version of the microscope with up to 350× magnification will use a nozzle-based source.
- 1 August 2023
- Published by The Russian Academy of Sciences in Poverhnostʹ. Rentgenovskie, sinhrotronnye i nejtronnye issledovaniâ
- No. 8,p. 16-21
Sizing the EUV Laser-Plasma Source for a Microscope
The size and intensity of laser-plasma sources based on pulsed argon gas jets operating at a wavelength of 13.84 nm were studied. The gas jet was excited by laser radiation at a wavelength of 1064 nm with a pulse duration of 4.4 ns, a repetition frequency of 10 Hz, and a pulse energy of 0.5 J. Two methods of forming a jet of a pulsed gas target were studied: using a jet with a supersonic nozzle and using a capillary. The capillary source is commercially available. The sources were certified using a mirror microscope operating in the extreme ultraviolet region at a wavelength of 13.84 nm. It was found that due to the possibility of supplying a higher pressure of the working gas to the nozzle inlet, increasing the density and reducing the exit angle of the gas jet in the supersonic nozzle compared to the capillary, the peak radiation intensity at a wavelength of 13.84 nm increased six times. The full width at half maximum of the nozzle-based source diameter was 250 ± 10 μm with a profile close to Gaussian. In the field of view of a microscope of 25 × 25 μm, the nonuniformity of illumination from the “source on the nozzle” is about 1%; in the field of view of 50 × 50 μm, it is about 4%. The full width at half maximum of the source diameter based on a commercial valve with a capillary source was 330 ± 10 µm with a profile close to П-shaped. Based on the results of the comparison, an upgraded version of the microscope with up to 350× magnification will use a nozzle-based source.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 1032
Подложки для мягкой рентгеновской микроскопии на основе Si-=SUB=-3-=/SUB=-N-=SUB=-4-=/SUB=- мембран
Silicon nitride membranes were experimentally obtained as substrates for biological samples, which are examined using a microscope with an operating wavelength of 13.8 nm. The free-hanging films obtained have a size of up to 1.5 x 1.5 mm2, which makes it possible to select an area of interest for investigation on the sample on the order of tens to hundreds of microns. The mechanical strength of the membranes satisfies that the samples do not tear the membranes and withstand transportation. The results obtained are an import-substituting technology for the manufacture of Si3N4 membranes. The resulting membranes have a transparency of more than 40% in the range of the “water transparency window” (2.3–4.4 nm) and EUV (13–15 nm). The developed technology will become the basis for creating cuvettes for living biological samples for soft X-ray microscopy studies.
- 1 January 2023
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 93 (7) , 1032
Подложки для мягкой рентгеновской микроскопии на основе Si-=SUB=-3-=/SUB=-N-=SUB=-4-=/SUB=- мембран
Silicon nitride membranes were experimentally obtained as substrates for biological samples, which are examined using a microscope with an operating wavelength of 13.8 nm. The free-hanging films obtained have a size of up to 1.5 x 1.5 mm2, which makes it possible to select an area of interest for investigation on the sample on the order of tens to hundreds of microns. The mechanical strength of the membranes satisfies that the samples do not tear the membranes and withstand transportation. The results obtained are an import-substituting technology for the manufacture of Si3N4 membranes. The resulting membranes have a transparency of more than 40% in the range of the “water transparency window” (2.3–4.4 nm) and EUV (13–15 nm). The developed technology will become the basis for creating cuvettes for living biological samples for soft X-ray microscopy studies.