Masamichi Koyanagi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masamichi Koyanagi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Haruhiko Machida
Department of Radiology, Tokyo Women’s Medical University, Adachi Medical Center
1 shared publication - Keita Fukushima
Department of Radiology, Kyorin University Hospital, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan
1 shared publication - Kenichi Yokoyama
Department of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan
1 shared publication - Makiko Nishikawa
Department of Radiology, Tokyo Women’s Medical University Adachi Medical Center, 4-33-1 Kohoku, Adachi-ku 123-8558, Tokyo, Japan
1 shared publication - Toru Satoh
Division of Cardiology, Second Department of Internal Medicine, Kyorin University School of Medicine, Tokyo, Japan
1 shared publication - Toshiya Kariyasu
Department of Radiology, Faculty of Medicine, Kyorin University, 6-20-2 Shinkawa, Mitaka-shi 181-8611, Tokyo, Japan
1 shared publication
Latest Publications
- Open Access
- 21 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2895
Correlation between CT Value on Lung Subtraction CT and Radioactive Count on Perfusion Lung Single Photon Emission CT in Chronic Thromboembolic Pulmonary Hypertension
Background: Lung subtraction CT (LSCT), the subtraction of noncontrast CT from CT pulmonary angiography (CTPA) without spatial misregistration, is easily applicable by utilizing a software-based deformable image registration technique without additional hardware and permits the evaluation of lung perfusion as iodine accumulation, similar to that observed in perfusion lung single photon emission CT (PL-SPECT). The aim of this study was to use LSCT to newly assess the quantitative correlation between the CT value on LSCT and radioactive count on PL-SPECT as a reference and validate the quantification of lung perfusion by measuring the CT value in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: We prospectively enrolled 47 consecutive patients with CTEPH undergoing both LSCT and PL-SPECT; we used noncontrast CT, CTPA, and LSCT to measure CT values and PL-SPECT to measure radioactive counts in areas representing three different perfusion classes—no perfusion defect, subsegmental perfusion defect, and segmental perfusion defect; we compared CT values on noncontrast CT, CTPA, and LSCT and radioactive counts on PL-SPECT among the three classes, then assessed the correlation between them. Results: Both the CT values and radioactive counts differed significantly among the three classes (p < 0.01 for all) and showed weak correlation (ρ = 0.38) by noncontrast CT, moderate correlation (ρ = 0.61) by CTPA, and strong correlation (ρ = 0.76) by LSCT. Conclusions: The CT value measurement on LSCT is a novel quantitative approach to assess lung perfusion in CTEPH and only correlates strongly with radioactive count measurement on PL-SPECT.
- 21 November 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (11) , 2895
Open AccessCorrelation between CT Value on Lung Subtraction CT and Radioactive Count on Perfusion Lung Single Photon Emission CT in Chronic Thromboembolic Pulmonary Hypertension
Background: Lung subtraction CT (LSCT), the subtraction of noncontrast CT from CT pulmonary angiography (CTPA) without spatial misregistration, is easily applicable by utilizing a software-based deformable image registration technique without additional hardware and permits the evaluation of lung perfusion as iodine accumulation, similar to that observed in perfusion lung single photon emission CT (PL-SPECT). The aim of this study was to use LSCT to newly assess the quantitative correlation between the CT value on LSCT and radioactive count on PL-SPECT as a reference and validate the quantification of lung perfusion by measuring the CT value in chronic thromboembolic pulmonary hypertension (CTEPH). Methods: We prospectively enrolled 47 consecutive patients with CTEPH undergoing both LSCT and PL-SPECT; we used noncontrast CT, CTPA, and LSCT to measure CT values and PL-SPECT to measure radioactive counts in areas representing three different perfusion classes—no perfusion defect, subsegmental perfusion defect, and segmental perfusion defect; we compared CT values on noncontrast CT, CTPA, and LSCT and radioactive counts on PL-SPECT among the three classes, then assessed the correlation between them. Results: Both the CT values and radioactive counts differed significantly among the three classes (p < 0.01 for all) and showed weak correlation (ρ = 0.38) by noncontrast CT, moderate correlation (ρ = 0.61) by CTPA, and strong correlation (ρ = 0.76) by LSCT. Conclusions: The CT value measurement on LSCT is a novel quantitative approach to assess lung perfusion in CTEPH and only correlates strongly with radioactive count measurement on PL-SPECT.