RBReza Behkam

Reza Behkam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Reza Behkam has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A New High Voltage Gain Transformer-Less Step-Up DC–DC Converter With Double Duty-Cycles: Design and Analysis

    by Arash Imanlou, Arash Imanlou, Reza Behkam, Reza Behkam, Ali Nadermohammadi, Ali Nadermohammadi, Hamed Nafisi, Hamed Nafisi, Hamed Heydari-Doostabad, Hamed Heydari-Doostabad, et al.

    This paper proposes a new high gain step-up non-isolated transformer-less DC-DC converter, achieved through the effective integration of an active switched-inductor network with switched-capacitors. A substantially high voltage gain is achieved considering the quantity of components employed in its structure. Benefiting from double duty cycles, a notable attribute of the propounded circuit is its capability to obtain a consistent voltage gain through diverse duty cycle configurations. The second duty cycle introduces an additional degree of freedom to both the design procedure and the converter control system design. The pole placement control method is employed to regulate the converter, controlling both duty cycles simultaneously. The attainment of a high voltage gain, such as a gain of 20, is feasible through the use of low duty cycle values ( D 1 =50% and D 2 =35%). Also, the power switches are subject to less voltage stresses ( V S1 = V S2 =0.26 Vout and V S3 =0.48 Vout ), enabling the implementation of low voltage rating MOSFETs with low on-resistance, resulting in improved efficiency. Moreover, the output switch under zero-voltage switching (ZVS) conditions and low turn-off switching losses of the input switches lead to an increased efficiency. Omitting the use of a transformer or coupled-inductors in this design reduces the converter size and weight, eliminates the challenges of leakage inductors, and also simplifies analysis, design, and fabrication procedure. The operation principles, steady-state analysis, design considerations, and efficiency calculations are provided in detail, followed by dynamic modeling and control analysis. To assess the merits of the propounded converter, a comparison study is conducted against those of other relevant converters. Ultimately, for the purpose of validating the suggested design, the converter simulation model in PSIM software is tested, and a 300W laboratory prototype is fabricated and evaluated.


  • Open Access

    A New High Voltage Gain Active Switched-Inductor Based High Step-Up DC–DC Converter With Coupled-Inductor

    by Arash Imanlou, Ebrahim Seifi Najmi, Reza Behkam, Morteza Nazari-Heris, Gevork B. Gharehpetian

    This paper propounds a new high step-up DC-DC topology based on the active switched-inductor (A-SL) technique, which utilizes a coupled inductor (CI) for performance enhancement. Among the features of the presented topology are the following: (a) Better voltage gain (VG) and efficiency, (b) Since there are low voltages across power switches, it is possible to reduce the amount of power that is lost as a result of using MOSFETs with a low voltage rating and reduced internal resistance, (c) By reducing the turn ratio of the CI, the VG is enhanced, (d) Through the series connection of a capacitor with the CI primary winding, zero DC bias is achieved, and the core saturation problem is solved, (e) Input current division between input inductors and switches, (f) There is no limitation on duty cycle (0<D<1), and (g) Simple switching patterns and simultaneously driven switches. The propounded converter’s operation principle and steady-state analysis are explained in detail, and parasitic elements’ effects on VG and efficiency are examined. In addition, the VG, the number of components, and the voltage tension on power switches, diodes, and capacitors are compared and analyzed. An experimental laboratory prototype with 30V input and 400V output voltage is used to verify the validity of the study and the performance of the propounded topology.


  • Open Access

    Diagnosing Disk-Space Variation in Distribution Power Transformer Windings Using Group Method of Data Handling Artificial Neural Networks

    by Omid Elahi, Reza Behkam, Gevork B. Gharehpetian, Fazel Mohammadi

    Monitoring centers in the smart grid exchange the collected data by sensors and smart meters to monitor the current conditions and performance of electric power components. Distribution Power Transformers (DPTs) have a key role in maintaining the integrity of power flow in the smart grid. Online monitoring of DPTs to detect possible faults can potentially increase the reliability of modern power systems. Mechanical defects of DPTs are the major issues in their proper operation that must be detected in their early stage of occurrence. One of the most effective solutions for diagnosing mechanical defects in DPTs is Frequency Response Analysis (FRA). In this study, an appropriate condition monitoring scheme for DPTs is developed to identify even minor winding defects. Disk-Space Variation (DSV), a common DPT windings fault, is applied to the 20 kV-winding of a 1.6 MVA DPT in various locations and with different severity. Their corresponding frequency responses are then computed, and all four components of the frequency responses, i.e., amplitude, argument, and real and imaginary parts, are evaluated. Different data-driven-based indices are implemented to extract appropriate feature vectors in the preprocessing stage. Group Method of Data Handling (GMDH) Artificial Neural Networks is proposed to assist monitoring centers in interpreting FRA signatures and identifying DPT defects at primary stages. GMDH has a data-dependent structure, which gives high flexibility to modeling nonlinear characteristics of FRA test results with different data sizes. It is demonstrated that the proposed approach is capable of accurately determining the fault location and fault severity. The proposed Artificial Intelligence (AI)-based approach is used to extract essential features from frequency response traces in order to detect the position and degree of Disk-Space Variation (DSV) in the DPT windings. The experimental results verify the effectiveness of the proposed methods in determining the severity and location of DSV defects.