Takaaki Tanaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takaaki Tanaka has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Akihito Ochiai
Department of Science and Technology, Niigata University
5 shared publicationsMasayuki Taniguchi
Department of Advanced Materials Science and Technology, Graduate School of Science and Technology, Niigata, Japan
5 shared publications- Masayuki Taniguchi
Department of Materials Science and Technology, Graduate School of Science and Technology, Niigata University, Niigata 950-2181, Japan
3 shared publications Atsushi Yukimoto
Department of Gastroenterology and Metabology, Ehime University Graduate School of Medicine
2 shared publications- Francis Bond
Palacký University
2 shared publications Marino Fujisawa
Department of Materials Science and Technology Niigata University Niigata Japan
2 shared publications
Latest Publications
- 20 November 2026
- Published by Society of Chemical Engineers, Japan in KAGAKU KOGAKU RONBUNSHU
- Vol. 52 (6) , 111-115
Preparation of Poly(lactic acid) Filtration Membranes Using Mixed Solvents of Dimethyl Isosorbide and Polysorbate 80
本報では環境に優しい有機溶媒として注目されるジメチルイソソルビド(DMI)と界面活性剤ポリソルベート80の混合溶媒を用いてポリ乳酸製濾過膜を作製した.多孔質構造の形成には非溶媒として水を用いる非溶媒誘起相分離法を用いた.10%ポリソルベート80を含むDMI溶媒にて8%ポリ乳酸溶液を用いて濾過膜を作製すると膜抵抗が100% DMI溶媒の場合(2.9×1012 m−1)の190分の1に低下し,1.5×1010 m−1になった.ポリ乳酸溶液中の高分子濃度を高めると濾過抵抗が指数関数的に増加した.ϕ0.7×2.5 µmの乳酸菌の懸濁液を用いた微生物の阻止実験では高分子濃度を8%以上にすると阻止率が99%の濾過膜を作製することができた.高分子濃度8%で作製したポリ乳酸膜は牛血清アルブミンを90%透過させることができ,生分解性バイオマスプラスチック製精密濾過膜として利用されることが期待される.
- 20 November 2026
- Published by Society of Chemical Engineers, Japan in KAGAKU KOGAKU RONBUNSHU
- Vol. 52 (6) , 111-115
Preparation of Poly(lactic acid) Filtration Membranes Using Mixed Solvents of Dimethyl Isosorbide and Polysorbate 80
本報では環境に優しい有機溶媒として注目されるジメチルイソソルビド(DMI)と界面活性剤ポリソルベート80の混合溶媒を用いてポリ乳酸製濾過膜を作製した.多孔質構造の形成には非溶媒として水を用いる非溶媒誘起相分離法を用いた.10%ポリソルベート80を含むDMI溶媒にて8%ポリ乳酸溶液を用いて濾過膜を作製すると膜抵抗が100% DMI溶媒の場合(2.9×1012 m−1)の190分の1に低下し,1.5×1010 m−1になった.ポリ乳酸溶液中の高分子濃度を高めると濾過抵抗が指数関数的に増加した.ϕ0.7×2.5 µmの乳酸菌の懸濁液を用いた微生物の阻止実験では高分子濃度を8%以上にすると阻止率が99%の濾過膜を作製することができた.高分子濃度8%で作製したポリ乳酸膜は牛血清アルブミンを90%透過させることができ,生分解性バイオマスプラスチック製精密濾過膜として利用されることが期待される.
- Open Access
- 15 December 2025
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 26 (4) , 121-125
Studies on Membrane Filtration in Food Separation Process
食品工業では粒子の除去・回収に多数の分離プロセスが用いられている.本研究では環境循環型の粒子分離用の膜分離プロセスの開発を目指し,生分解性プラスチック製濾過膜の開発とデプスフィルターへの応用研究を行った.製膜法には主として相分離法を,酵母や乳酸菌の膜分離を行った.ポリ乳酸製濾過膜の作製では相分離前の高分子溶液表面の部分乾燥や高分子溶液への界面活性剤の添加により,乳酸菌を阻止可能な膜が作製できることを示した.作製した非対称膜は,粗い面側から濾過を行うとデプスフィルターとして機能し,高い濾過速度が得られた.また,セルロース繊維とポリヒドロキシアルカノエートの複合膜においては,セルロース繊維側から酵母懸濁液の濾過を行うと高い濾過速度が得られることを示した.本研究で開発した生分解性プラスチック製濾過膜やデプスフィルターが食品工業における粒子の除去・回収プロセスの改善につながることが期待される.
- 15 December 2025
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 26 (4) , 121-125
Open AccessStudies on Membrane Filtration in Food Separation Process
食品工業では粒子の除去・回収に多数の分離プロセスが用いられている.本研究では環境循環型の粒子分離用の膜分離プロセスの開発を目指し,生分解性プラスチック製濾過膜の開発とデプスフィルターへの応用研究を行った.製膜法には主として相分離法を,酵母や乳酸菌の膜分離を行った.ポリ乳酸製濾過膜の作製では相分離前の高分子溶液表面の部分乾燥や高分子溶液への界面活性剤の添加により,乳酸菌を阻止可能な膜が作製できることを示した.作製した非対称膜は,粗い面側から濾過を行うとデプスフィルターとして機能し,高い濾過速度が得られた.また,セルロース繊維とポリヒドロキシアルカノエートの複合膜においては,セルロース繊維側から酵母懸濁液の濾過を行うと高い濾過速度が得られることを示した.本研究で開発した生分解性プラスチック製濾過膜やデプスフィルターが食品工業における粒子の除去・回収プロセスの改善につながることが期待される.
- 3 June 2025
- Published by Wiley in Separation Science Plus
- Vol. 8 (6)
Preparation of Composite Monoliths of Poly(Methyl Methacrylate) and Hydroxyapatite for Protein Separation
Porous composite monoliths of poly(methyl methacrylate) and hydroxyapatite were prepared for protein separation. Poly(methyl methacrylate) skeletons of the monoliths were prepared from poly(methyl methacrylate) solutions in alcohol‐water mixed solvents using a thermally induced phase separation method. Wet hydroxyapatite particles (10 × 100 nm) were homogeneously composited as adsorbents in the porous poly(methyl methacrylate) structure during the phase separation process, whereas dried hydroxyapatite particles were not dispersed in the poly(methyl methacrylate) solutions. The composite monoliths were used to separate native and PEGylated lysozymes. Native lysozyme was preferentially adsorbed by the monolith in a 10 mM sodium phosphate buffer (pH 7). The PEGylated lysozyme was recovered in the flow‐through and washing fractions using the same buffer. The adsorbed native lysozyme was eluted with 400 mM sodium phosphate buffer. The separation was repeated after washing the monolith with 800 and 10 mM sodium phosphate buffers. The developed composite monolith enabled the purity of the PEGylated lysozyme to be increased from 60 ± 2% to 88 ± 3% ( n = 5) by changing the buffers during the five repeated uses. The composite monolith is thus a promising adsorbent for separating native and PEGylated proteins during biopharmaceutical processes.
- 3 June 2025
- Published by Wiley in Separation Science Plus
- Vol. 8 (6)
Preparation of Composite Monoliths of Poly(Methyl Methacrylate) and Hydroxyapatite for Protein Separation
Porous composite monoliths of poly(methyl methacrylate) and hydroxyapatite were prepared for protein separation. Poly(methyl methacrylate) skeletons of the monoliths were prepared from poly(methyl methacrylate) solutions in alcohol‐water mixed solvents using a thermally induced phase separation method. Wet hydroxyapatite particles (10 × 100 nm) were homogeneously composited as adsorbents in the porous poly(methyl methacrylate) structure during the phase separation process, whereas dried hydroxyapatite particles were not dispersed in the poly(methyl methacrylate) solutions. The composite monoliths were used to separate native and PEGylated lysozymes. Native lysozyme was preferentially adsorbed by the monolith in a 10 mM sodium phosphate buffer (pH 7). The PEGylated lysozyme was recovered in the flow‐through and washing fractions using the same buffer. The adsorbed native lysozyme was eluted with 400 mM sodium phosphate buffer. The separation was repeated after washing the monolith with 800 and 10 mM sodium phosphate buffers. The developed composite monolith enabled the purity of the PEGylated lysozyme to be increased from 60 ± 2% to 88 ± 3% ( n = 5) by changing the buffers during the five repeated uses. The composite monolith is thus a promising adsorbent for separating native and PEGylated proteins during biopharmaceutical processes.
- Open Access
- 15 September 2024
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 25 (3) , 59-64
Composite Membranes of Polyhydroxyalkanoate and Cellulose for Depth Filtration
In this study, we developed composite membranes of biorenewable and biodegradable polyhydroxyalkanoate (PHA) and cellulose for depth filtration. The membranes were prepared by coating PHA solutions in N,N-dimethylformamide onto cellulose lint cloth, followed by the phase separation method. Approximately half of the PHA porous layer was integrated into the cellulose fiber layer of the lint cloth. The average permeation flux was five-fold higher when yeast cell suspensions were filtered from the cloth side of the membrane than from the PHA side. The permeation behavior of filtration from the PHA side followed the cake filtration model, resulting in a dense cake layer. However, when the yeast suspension was filtered from the cloth side, yeast cells were captured in the cellulose fiber network, indicating a less increase in filtration resistance. These composite membranes are expected to facilitate the development of sustainable and efficient filter media in food and biochemical processes.
- 15 September 2024
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 25 (3) , 59-64
Open AccessComposite Membranes of Polyhydroxyalkanoate and Cellulose for Depth Filtration
In this study, we developed composite membranes of biorenewable and biodegradable polyhydroxyalkanoate (PHA) and cellulose for depth filtration. The membranes were prepared by coating PHA solutions in N,N-dimethylformamide onto cellulose lint cloth, followed by the phase separation method. Approximately half of the PHA porous layer was integrated into the cellulose fiber layer of the lint cloth. The average permeation flux was five-fold higher when yeast cell suspensions were filtered from the cloth side of the membrane than from the PHA side. The permeation behavior of filtration from the PHA side followed the cake filtration model, resulting in a dense cake layer. However, when the yeast suspension was filtered from the cloth side, yeast cells were captured in the cellulose fiber network, indicating a less increase in filtration resistance. These composite membranes are expected to facilitate the development of sustainable and efficient filter media in food and biochemical processes.
- 27 November 2022
- Published by Wiley in Journal of Separation Science
- Vol. 46 (2) , e2200638
Preparation of composite monoliths of quaternized chitosan and diatom earth for protein separation
In this study, composite monoliths with porous structures were prepared using quaternized chitosan and diatom earth for protein separation. Quaternized chitosan (N‐[(2‐hydroxy‐3‐trimethylammonium)propyl] chitosan chloride) dissolved in water was mixed with diatom earth and crosslinked with glutaraldehyde under low‐temperature conditions to form a cryogel. Interconnected porous monoliths were obtained after removing ice crystals from the cryogel. The monoliths adsorbed bovine serum albumin selectively from the solution mixture of bovine serum albumin and bovine ɤ‐globulin, and bovine ɤ‐globulin was recovered in the flow‐through fraction. The adsorption selectivity was enhanced by changing the solution pH from 6.8 to 5.5. The adsorption of bovine serum albumin by the monolith was replicated at least five times following its washing with a buffer containing 400 mM NaCl and subsequent regeneration with a 10 mM acetate buffer. The composited monolith is a promising adsorbent for the removal of acidic proteins, such as serum albumin contamination in neutral proteins, for example, ɤ‐globulins, in bioproduction processes.
- 27 November 2022
- Published by Wiley in Journal of Separation Science
- Vol. 46 (2) , e2200638
Preparation of composite monoliths of quaternized chitosan and diatom earth for protein separation
In this study, composite monoliths with porous structures were prepared using quaternized chitosan and diatom earth for protein separation. Quaternized chitosan (N‐[(2‐hydroxy‐3‐trimethylammonium)propyl] chitosan chloride) dissolved in water was mixed with diatom earth and crosslinked with glutaraldehyde under low‐temperature conditions to form a cryogel. Interconnected porous monoliths were obtained after removing ice crystals from the cryogel. The monoliths adsorbed bovine serum albumin selectively from the solution mixture of bovine serum albumin and bovine ɤ‐globulin, and bovine ɤ‐globulin was recovered in the flow‐through fraction. The adsorption selectivity was enhanced by changing the solution pH from 6.8 to 5.5. The adsorption of bovine serum albumin by the monolith was replicated at least five times following its washing with a buffer containing 400 mM NaCl and subsequent regeneration with a 10 mM acetate buffer. The composited monolith is a promising adsorbent for the removal of acidic proteins, such as serum albumin contamination in neutral proteins, for example, ɤ‐globulins, in bioproduction processes.
- Open Access
- 1 November 2022
- Published by Japan Society of Hepatology in Kanzo
- Vol. 63 (11) , 473-481
A case of alcohol-related liver cirrhosis diagnosed with thrombotic microangiopathy by renal biopsy
症例は70歳男性.アルコール性肝硬変の経過中にアルコール性肝炎を合併し入院した.血尿を伴うネフローゼ症候群を呈しており,禁酒,利尿剤と栄養療法の導入により蛋白尿は改善した.顕微鏡的血尿が残存したため腎生検を実施し,血栓性微小血管障害症(TMA)と診断した.血漿ADAMTS13活性低下とvon Willebrand factor(VWF)抗原高値がみられ,肝星細胞減少によるADAMTS13産生低下がTMAの原因と想定された.ADAMTS13補充目的に新鮮凍結血漿(FFP)の投与,内皮細胞障害に対してトロンボモジュリン製剤(rTM)を開始した.FFPの漸減,中止後もADAMTS13活性の低下はみられず,腎機能が維持された.肝硬変の経過中に血尿が出現した場合,ADAMTS13活性低下とVWF抗原とのインバランスがある場合はTMAを疑い,FFPやrTMの投与を考慮する必要があると考えられた.
- 1 November 2022
- Published by Japan Society of Hepatology in Kanzo
- Vol. 63 (11) , 473-481
Open AccessA case of alcohol-related liver cirrhosis diagnosed with thrombotic microangiopathy by renal biopsy
症例は70歳男性.アルコール性肝硬変の経過中にアルコール性肝炎を合併し入院した.血尿を伴うネフローゼ症候群を呈しており,禁酒,利尿剤と栄養療法の導入により蛋白尿は改善した.顕微鏡的血尿が残存したため腎生検を実施し,血栓性微小血管障害症(TMA)と診断した.血漿ADAMTS13活性低下とvon Willebrand factor(VWF)抗原高値がみられ,肝星細胞減少によるADAMTS13産生低下がTMAの原因と想定された.ADAMTS13補充目的に新鮮凍結血漿(FFP)の投与,内皮細胞障害に対してトロンボモジュリン製剤(rTM)を開始した.FFPの漸減,中止後もADAMTS13活性の低下はみられず,腎機能が維持された.肝硬変の経過中に血尿が出現した場合,ADAMTS13活性低下とVWF抗原とのインバランスがある場合はTMAを疑い,FFPやrTMの投与を考慮する必要があると考えられた.
- 24 December 2020
- Published by Wiley in Hepatology Research
- Vol. 51 (3) , 284-293
Dilatation of lymphatic vessels increases liver stiffness on transient elastography irrespective of fibrosis
Aim: Liver stiffness measured using transient elastography (TE) is affected by tissue viscosity. The role of intrahepatic lymphatic fluid in liver stiffness is unclear. The present study aimed to investigate the effects of lymphatic vessel dilatation on liver stiffness.Methods: Patients with chronic liver disease (n = 116) were enrolled from June 2018 to March 2020. All specimens were acquired by laparoscopic liver biopsy. Biopsy samples were stained with D2‐40 for lymphatic vessel quantification based on a five‐point scale for each specimen. Independent associations of liver stiffness measured by TE, strain elasticity (liver fibrosis index), and controlled attenuation parameter with fibrosis, lymphatic vessels, alanine aminotransferase, bilirubin, and steatosis were evaluated.Results: Fibrosis, splenic stiffness measurement, and splenic volume were significantly correlated with the area of lymphatic vessels. Fibrosis, lymphatic vessels, and alanine aminotransferase were independent factors significantly associated with liver stiffness measurement (LSM; standardized coefficient [β] = 0.375, P < 0.001; β = 0.342, P < 0.001; and β = 0.359, P < 0.001, respectively). Fibrosis was the only independent factor significantly associated with liver fibrosis index (β = 0.360, P < 0.001), whereas the fat deposit area was the only independent factor significantly associated with controlled attenuation parameter (β = 0.455, P < 0.001). The areas under the receiver operating characteristic curves for diagnosing controlled ascites based on LSM, liver fibrosis index, splenic stiffness measurement, collagen proportionate area, and area of lymphatic vessels were 0.94, 0.66, 0.76, 0.64, and 0.79, respectively.Conclusions: Lymphatic vessel dilatation can affect liver stiffness measured using TE. Liver stiffness measurement is a predictive factor for ascites.
- 24 December 2020
- Published by Wiley in Hepatology Research
- Vol. 51 (3) , 284-293
Dilatation of lymphatic vessels increases liver stiffness on transient elastography irrespective of fibrosis
Aim: Liver stiffness measured using transient elastography (TE) is affected by tissue viscosity. The role of intrahepatic lymphatic fluid in liver stiffness is unclear. The present study aimed to investigate the effects of lymphatic vessel dilatation on liver stiffness.Methods: Patients with chronic liver disease (n = 116) were enrolled from June 2018 to March 2020. All specimens were acquired by laparoscopic liver biopsy. Biopsy samples were stained with D2‐40 for lymphatic vessel quantification based on a five‐point scale for each specimen. Independent associations of liver stiffness measured by TE, strain elasticity (liver fibrosis index), and controlled attenuation parameter with fibrosis, lymphatic vessels, alanine aminotransferase, bilirubin, and steatosis were evaluated.Results: Fibrosis, splenic stiffness measurement, and splenic volume were significantly correlated with the area of lymphatic vessels. Fibrosis, lymphatic vessels, and alanine aminotransferase were independent factors significantly associated with liver stiffness measurement (LSM; standardized coefficient [β] = 0.375, P < 0.001; β = 0.342, P < 0.001; and β = 0.359, P < 0.001, respectively). Fibrosis was the only independent factor significantly associated with liver fibrosis index (β = 0.360, P < 0.001), whereas the fat deposit area was the only independent factor significantly associated with controlled attenuation parameter (β = 0.455, P < 0.001). The areas under the receiver operating characteristic curves for diagnosing controlled ascites based on LSM, liver fibrosis index, splenic stiffness measurement, collagen proportionate area, and area of lymphatic vessels were 0.94, 0.66, 0.76, 0.64, and 0.79, respectively.Conclusions: Lymphatic vessel dilatation can affect liver stiffness measured using TE. Liver stiffness measurement is a predictive factor for ascites.
- Open Access
- 19 June 2019
- Published by MDPI AG in Biomedicines
- Vol. 7 (2) , 45
Evidence for Contamination of Silica Microparticles in Advanced Platelet-Rich Fibrin Matrices Prepared Using Silica-Coated Plastic Tubes
Platelet-rich fibrin (PRF) therapy has been widely applied in regenerative dentistry, and PRF preparation has been optimized to efficiently form fibrin clots using plain glass tubes. Currently, a shortage of commercially available glass tubes has forced PRF users to utilize silica-coated plastic tubes. However, most plastic tubes are approved by regulatory authorities only for diagnostic use and remain to be approved for PRF therapy. To clarify this issue, we quantified silica microparticles incorporated into the PRF matrix. Blood samples were collected into three different brands of silica-containing plastic tubes and were immediately centrifuged following the protocol for advanced-PRF (A-PRF). Advanced-PRF-like matrices were examined using a scanning electron microscope (SEM), and silica microparticles were quantified using a spectrophotometer. Each brand used silica microparticles of specific size and appearance. Regardless of tube brands and individual donors, significant, but not accidental, levels of silica microparticles were found to be incorporated into the A-PRF-like matrix, which will be consequently incorporated into the implantation sites. Presently, from the increasing data for cytotoxicity of amorphous silica, we cannot exclude the possibility that such A-PRF-like matrices negatively influence tissue regeneration through induction of inflammation. Further investigation should be performed to clarify such potential risks.
- 19 June 2019
- Published by MDPI AG in Biomedicines
- Vol. 7 (2) , 45
Open AccessEvidence for Contamination of Silica Microparticles in Advanced Platelet-Rich Fibrin Matrices Prepared Using Silica-Coated Plastic Tubes
Platelet-rich fibrin (PRF) therapy has been widely applied in regenerative dentistry, and PRF preparation has been optimized to efficiently form fibrin clots using plain glass tubes. Currently, a shortage of commercially available glass tubes has forced PRF users to utilize silica-coated plastic tubes. However, most plastic tubes are approved by regulatory authorities only for diagnostic use and remain to be approved for PRF therapy. To clarify this issue, we quantified silica microparticles incorporated into the PRF matrix. Blood samples were collected into three different brands of silica-containing plastic tubes and were immediately centrifuged following the protocol for advanced-PRF (A-PRF). Advanced-PRF-like matrices were examined using a scanning electron microscope (SEM), and silica microparticles were quantified using a spectrophotometer. Each brand used silica microparticles of specific size and appearance. Regardless of tube brands and individual donors, significant, but not accidental, levels of silica microparticles were found to be incorporated into the A-PRF-like matrix, which will be consequently incorporated into the implantation sites. Presently, from the increasing data for cytotoxicity of amorphous silica, we cannot exclude the possibility that such A-PRF-like matrices negatively influence tissue regeneration through induction of inflammation. Further investigation should be performed to clarify such potential risks.