Sydney Nicole Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sydney Nicole Williams has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Shajan Gunamony
Imaging Center of Excellence University of Glasgow Glasgow UK
4 shared publications Paul McElhinney
Imaging Centre of Excellence University of Glasgow Glasgow UK
3 shared publicationsSarah Allwood‐Spiers
MRI Physics NHS Greater Glasgow and Clyde Glasgow UK
3 shared publications- Belinda Ding
Siemens Healthcare Ltd Camberley UK
2 shared publications David Andrew Porter
Imaging Centre of Excellence University of Glasgow Glasgow UK
2 shared publications- Patrick Liebig
Siemens Healthineers AG Erlangen Germany
2 shared publications
Latest Publications
- Open Access
- 29 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 386-400
Simultaneous whole‐brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8‐channel transceiver array and 56‐channel receiver array
Purpose: To develop a 7T neurovascular head and neck (NVHN) coil with an extended longitudinal coverage of the brain and cervical spine, with eight transceiver (TxRx) channels and 56 receive (Rx) channels for dynamic parallel‐transmit (pTx) applications. Methods: A dual‐row transceiver array with six elements in the upper row and two elements in the lower row was designed using combined electromagnetic and circuit optimization and constructed. A 56Rx array covering the brain and cervical spine was designed and combined with the transceiver array. The performance of the 8TxRx56Rx NVHN coil such as , signal‐to‐noise ratio, and g‐factor were validated in phantom and in vivo studies and compared with an in‐house 8Tx64Rx head coil. High‐resolution in vivo images were acquired with the NVHN and head coil. Results: The average in phantom while exciting the upper six channels and all eight channels are 43.45 nT/V and 45.80 nT/V, respectively, demonstrating that the available field is seamlessly distributed in the brain and/or cervical spine, depending on the chosen excitation. The 8TxRx56Rx NVHN coil increases the SNR in the cervical spine and central brain by a factor of 2.18 and 1.16, respectively, compared with the 8Tx64Rx head coil. Furthermore, it demonstrates similar 1/g‐factor performance for acceleration factors up to 5 × 5 compared with the head coil and provides diagnostic‐quality images of the brain and spinal cord in a single acquisition. Conclusion: The extended longitudinal coverage of the NVHN coil promises to improve the clinical application of the current generation of pTx 7T MRI systems with 8Tx channels.
- 29 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 386-400
Open AccessSimultaneous whole‐brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8‐channel transceiver array and 56‐channel receiver array
Purpose: To develop a 7T neurovascular head and neck (NVHN) coil with an extended longitudinal coverage of the brain and cervical spine, with eight transceiver (TxRx) channels and 56 receive (Rx) channels for dynamic parallel‐transmit (pTx) applications. Methods: A dual‐row transceiver array with six elements in the upper row and two elements in the lower row was designed using combined electromagnetic and circuit optimization and constructed. A 56Rx array covering the brain and cervical spine was designed and combined with the transceiver array. The performance of the 8TxRx56Rx NVHN coil such as , signal‐to‐noise ratio, and g‐factor were validated in phantom and in vivo studies and compared with an in‐house 8Tx64Rx head coil. High‐resolution in vivo images were acquired with the NVHN and head coil. Results: The average in phantom while exciting the upper six channels and all eight channels are 43.45 nT/V and 45.80 nT/V, respectively, demonstrating that the available field is seamlessly distributed in the brain and/or cervical spine, depending on the chosen excitation. The 8TxRx56Rx NVHN coil increases the SNR in the cervical spine and central brain by a factor of 2.18 and 1.16, respectively, compared with the 8Tx64Rx head coil. Furthermore, it demonstrates similar 1/g‐factor performance for acceleration factors up to 5 × 5 compared with the head coil and provides diagnostic‐quality images of the brain and spinal cord in a single acquisition. Conclusion: The extended longitudinal coverage of the NVHN coil promises to improve the clinical application of the current generation of pTx 7T MRI systems with 8Tx channels.
- Open Access
- 1 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Slice‐specific B1+ shimming improves the repeatability of multishot DWI at 7 T
Purpose: Compared with lower field strengths, DWI at 7 T faces the combined challenges of increased distortion and blurring due to B0 inhomogeneity, and increased signal dropouts due to B1+ inhomogeneity. This study addresses the B1+ limitations using slice‐specific static parallel transmission (pTx) in a multi‐shot, readout‐segmented EPI diffusion imaging sequence.Methods: DWI was performed in 7 healthy subjects using MRI at 7 T and readout‐segmented EPI. Data were acquired with non‐pTx circular‐polarized (CP) pulses (CP‐DWI) and static pTx pulses (pTx‐DWI) using slice‐specific B1+ shim coefficients. Each volunteer underwent two scan sessions on the same day, with two runs of each sequence in the first session and one run in the second. The sequences were evaluated by assessing image quality, flip‐angle homogeneity, and intrasession and intersession repeatability in ADC estimates.Results: pTx‐DWI significantly reduced signal voids compared with CP‐DWI, particularly in inferior brain regions. The use of pTx also improved RF uniformity and symmetry across the brain. These effects translated into improved intrasession and intersession repeatability for pTx‐DWI. Additionally, re‐optimizing the pTx pulse between repeat scans did not have a negative effect on ADC repeatability.Conclusion: The study demonstrates that pTx provides a reproducible image‐quality increase in multishot DWI at 7 T. The benefits of pTx also extend to quantitative ADC estimation with regard to the improvement in intrasession and intersession repeatability. Overall, the combination of multishot imaging and pTx can support the development of reliable, high‐resolution DWI for clinical studies at 7 T.
- 1 August 2024
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessSlice‐specific B1+ shimming improves the repeatability of multishot DWI at 7 T
Purpose: Compared with lower field strengths, DWI at 7 T faces the combined challenges of increased distortion and blurring due to B0 inhomogeneity, and increased signal dropouts due to B1+ inhomogeneity. This study addresses the B1+ limitations using slice‐specific static parallel transmission (pTx) in a multi‐shot, readout‐segmented EPI diffusion imaging sequence.Methods: DWI was performed in 7 healthy subjects using MRI at 7 T and readout‐segmented EPI. Data were acquired with non‐pTx circular‐polarized (CP) pulses (CP‐DWI) and static pTx pulses (pTx‐DWI) using slice‐specific B1+ shim coefficients. Each volunteer underwent two scan sessions on the same day, with two runs of each sequence in the first session and one run in the second. The sequences were evaluated by assessing image quality, flip‐angle homogeneity, and intrasession and intersession repeatability in ADC estimates.Results: pTx‐DWI significantly reduced signal voids compared with CP‐DWI, particularly in inferior brain regions. The use of pTx also improved RF uniformity and symmetry across the brain. These effects translated into improved intrasession and intersession repeatability for pTx‐DWI. Additionally, re‐optimizing the pTx pulse between repeat scans did not have a negative effect on ADC repeatability.Conclusion: The study demonstrates that pTx provides a reproducible image‐quality increase in multishot DWI at 7 T. The benefits of pTx also extend to quantitative ADC estimation with regard to the improvement in intrasession and intersession repeatability. Overall, the combination of multishot imaging and pTx can support the development of reliable, high‐resolution DWI for clinical studies at 7 T.
- Open Access
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 645-659
Intra‐scan RF power amplifier drift correction
Purpose: The drift in radiofrequency (RF) power amplifiers (RFPAs) is assessed and several contributing factors are investigated. Two approaches for prospective correction of drift are proposed and their effectiveness is evaluated.Methods: RFPA drift assessment encompasses both intra‐pulse and inter‐pulse drift analyses. Scan protocols with varying flip angle (FA), RF length, and pulse repetition time (TR) are used to gauge the influence of these parameters on drift. Directional couplers (DICOs) monitor the forward waveforms of the RFPA outputs. DICOs data is stored for evaluation, allowing calculation of correction factors to adjust RFPAs' transmit voltage. Two correction methods, predictive and run‐time, are employed: predictive correction necessitates a calibration scan, while run‐time correction calculates factors during the ongoing scan.Results: RFPA drift is indeed influenced by the RF duty‐cycle, and in the cases examined with a maximum duty‐cycle of 66%, the potential drift is approximately 41% or 15%, depending on the specific RFPA revision. Notably, in low transmit voltage scenarios, FA has minimal impact on RFPA drift. The application of predictive and run‐time drift correction techniques effectively reduces the average drift from 10.0% to less than 1%, resulting in enhanced MR signal stability.Conclusion: Utilizing DICO recordings and implementing a feedback mechanism enable the prospective correction of RFPA drift. Having a calibration scan, predictive correction can be utilized with fewer complexity; for enhanced performance, a run‐time approach can be employed.
- 12 March 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (2) , 645-659
Open AccessIntra‐scan RF power amplifier drift correction
Purpose: The drift in radiofrequency (RF) power amplifiers (RFPAs) is assessed and several contributing factors are investigated. Two approaches for prospective correction of drift are proposed and their effectiveness is evaluated.Methods: RFPA drift assessment encompasses both intra‐pulse and inter‐pulse drift analyses. Scan protocols with varying flip angle (FA), RF length, and pulse repetition time (TR) are used to gauge the influence of these parameters on drift. Directional couplers (DICOs) monitor the forward waveforms of the RFPA outputs. DICOs data is stored for evaluation, allowing calculation of correction factors to adjust RFPAs' transmit voltage. Two correction methods, predictive and run‐time, are employed: predictive correction necessitates a calibration scan, while run‐time correction calculates factors during the ongoing scan.Results: RFPA drift is indeed influenced by the RF duty‐cycle, and in the cases examined with a maximum duty‐cycle of 66%, the potential drift is approximately 41% or 15%, depending on the specific RFPA revision. Notably, in low transmit voltage scenarios, FA has minimal impact on RFPA drift. The application of predictive and run‐time drift correction techniques effectively reduces the average drift from 10.0% to less than 1%, resulting in enhanced MR signal stability.Conclusion: Utilizing DICO recordings and implementing a feedback mechanism enable the prospective correction of RFPA drift. Having a calibration scan, predictive correction can be utilized with fewer complexity; for enhanced performance, a run‐time approach can be employed.
- Open Access
- 18 January 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (2) , 02TR02
Ultra-high field MRI: parallel-transmit arrays and RF pulse design
This paper reviews the field of multiple or parallel radiofrequency (RF) transmission for magnetic resonance imaging (MRI). Currently the use of ultra-high field (UHF) MRI at 7 tesla and above is gaining popularity, yet faces challenges with non-uniformity of the RF field and higher RF power deposition. Since its introduction in the early 2000s, parallel transmission (pTx) has been recognized as a powerful tool for accelerating spatially selective RF pulses and combating the challenges associated with RF inhomogeneity at UHF. We provide a survey of the types of dedicated RF coils used commonly for pTx and the important modeling of the coil behavior by electromagnetic (EM) field simulations. We also discuss the additional safety considerations involved with pTx such as the specific absorption rate (SAR) and how to manage them. We then describe the application of pTx with RF pulse design, including a practical guide to popular methods. Finally, we conclude with a description of the current and future prospects for pTx, particularly its potential for routine clinical use.
- 18 January 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (2) , 02TR02
Open AccessUltra-high field MRI: parallel-transmit arrays and RF pulse design
This paper reviews the field of multiple or parallel radiofrequency (RF) transmission for magnetic resonance imaging (MRI). Currently the use of ultra-high field (UHF) MRI at 7 tesla and above is gaining popularity, yet faces challenges with non-uniformity of the RF field and higher RF power deposition. Since its introduction in the early 2000s, parallel transmission (pTx) has been recognized as a powerful tool for accelerating spatially selective RF pulses and combating the challenges associated with RF inhomogeneity at UHF. We provide a survey of the types of dedicated RF coils used commonly for pTx and the important modeling of the coil behavior by electromagnetic (EM) field simulations. We also discuss the additional safety considerations involved with pTx such as the specific absorption rate (SAR) and how to manage them. We then describe the application of pTx with RF pulse design, including a practical guide to popular methods. Finally, we conclude with a description of the current and future prospects for pTx, particularly its potential for routine clinical use.
- Open Access
- 9 January 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 1888-1900
The effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel‐transmit pulses at 7 T
Purpose: To investigate the effects of using different parallel‐transmit (pTx) head coils and specific absorption rate (SAR) supervision strategies on pTx pulse design for ultrahigh‐field MRI using a 3D‐MPRAGE sequence.Methods: The PTx universal pulses (UPs) and fast online‐customized (FOCUS) pulses were designed with pre‐acquired data sets (B0, B1+ maps, specific absorption rate [SAR] supervision data) from two different 8 transmit/32 receive head coils on two 7T whole‐body MR systems. For one coil, the SAR supervision model consisted of per‐channel RF power limits. In the other coil, SAR estimations were done with both per‐channel RF power limits as well as virtual observation points (VOPs) derived from electromagnetic field (EMF) simulations using three virtual human body models at three different positions. All pulses were made for nonselective excitation and inversion and evaluated on 132 B0, B1+, and SAR supervision datasets obtained with one coil and 12 from the other. At both sites, 3 subjects were examined using MPRAGE sequences that used UP/FOCUS pulses generated for both coils.Results: For some subjects, the UPs underperformed when simulated on a different coil from which they were derived, whereas FOCUS pulses still showed acceptable performance in that case. FOCUS inversion pulses outperformed adiabatic pulses when scaled to the same local SAR level. For the self‐built coil, the use of VOPs showed reliable overestimation compared with the ground‐truth EMF simulations, predicting about 52% lower local SAR for inversion pulses compared with per‐channel power limits.Conclusion: FOCUS inversion pulses offer a low‐SAR alternative to adiabatic pulses and benefit from using EMF‐based VOPs for SAR estimation.
- 9 January 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (5) , 1888-1900
Open AccessThe effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel‐transmit pulses at 7 T
Purpose: To investigate the effects of using different parallel‐transmit (pTx) head coils and specific absorption rate (SAR) supervision strategies on pTx pulse design for ultrahigh‐field MRI using a 3D‐MPRAGE sequence.Methods: The PTx universal pulses (UPs) and fast online‐customized (FOCUS) pulses were designed with pre‐acquired data sets (B0, B1+ maps, specific absorption rate [SAR] supervision data) from two different 8 transmit/32 receive head coils on two 7T whole‐body MR systems. For one coil, the SAR supervision model consisted of per‐channel RF power limits. In the other coil, SAR estimations were done with both per‐channel RF power limits as well as virtual observation points (VOPs) derived from electromagnetic field (EMF) simulations using three virtual human body models at three different positions. All pulses were made for nonselective excitation and inversion and evaluated on 132 B0, B1+, and SAR supervision datasets obtained with one coil and 12 from the other. At both sites, 3 subjects were examined using MPRAGE sequences that used UP/FOCUS pulses generated for both coils.Results: For some subjects, the UPs underperformed when simulated on a different coil from which they were derived, whereas FOCUS pulses still showed acceptable performance in that case. FOCUS inversion pulses outperformed adiabatic pulses when scaled to the same local SAR level. For the self‐built coil, the use of VOPs showed reliable overestimation compared with the ground‐truth EMF simulations, predicting about 52% lower local SAR for inversion pulses compared with per‐channel power limits.Conclusion: FOCUS inversion pulses offer a low‐SAR alternative to adiabatic pulses and benefit from using EMF‐based VOPs for SAR estimation.