STSi Tang

Si Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Si Tang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative mapping of cell–cell interactions using the micropipette force sensor

    by Huiyao Shi, Si Tang, Jialin Shi, Chanmin Su, Lianqing Liu

    Mechanical interactions among cells play an essential role in immune processes and tumorigenesis. However, quantitative mapping of the interactions between suspended cells remains challenging. In this study, an approach based on micropipette force sensors (MFS) has been developed for accurately manipulating cells and mapping intercellular interactions. The proposed method utilizes a holding probe to support the cells and an MFS probe for interaction force sensing; the intercellular interactions are quantified through force curve measurements in the approach-retraction process. To demonstrate the versatility of our technique, we measured the cell–substrate, cell–adherent, and cell-suspended interactions using mouse neuroblastoma N2a cells (Neuro2A). We demonstrated the potential of our method for measuring various cellular mechanical forces and revealed an increase in the stiffness of Neuro2A cells during mechanical measurements, which may be associated with cytoskeletal reinforcement in response to mechanical stimuli. The proposed technique has substantial implications for studying receptor-ligand effects on immune cells and intercellular adhesion. This advancement provides a method to enhance the comprehension of cellular mechanics and offers a tool for potential biomedical applications.


  • Mechano-Electrophysiological Signals Measuring System Based on Cantilevered Micropipette Force Electric Sensor

    by Huiyao Shi, Jialin Shi, Si Tang, Peng Yu, Chanmin Su, Lianqing Liu

    Cardiomyocytes (CMs) are the contractile motors of the heart that generate the force required to pump blood into the systemic circulations. Its contractive process can be described as electrical stimulation that ultimately leads force generation (excitation–contraction coupling). Investigation of the mechanical forces and electrical signals is crucial in heart disease research and related drug assessment. Despite the long-term development of instruments for measuring mechanical or electrical signals of CMs separately, in-situ synchronous measurement of these signals of CMs still faces challenges. To address this gap, in this study, we developed cantilevered micropipette force electric sensor (CMFES) to realize mechanical and electrical signal measurements. We recorded, for the first time, the synchronous local beating, ion flow-related contraction characteristics, and action potential of CMs. The results revealed that during the late stage of Na+ influx in CMs, the cells began to contract, with a time difference of approximately 100–130 ms between the action potential and the contraction peak. Furthermore, to demonstrate the accuracy and capability of the proposed methods, we utilized CMFES to perform quantitative mechanical measurements, achieve high-resistance sealing, and record ion channel currents. In summary, our approach achieved measurement accuracy comparable to that of atomic force microscopy (AFM) and patch clamp techniques, which are currently considered the most precise technologies for mechanical and electrical measurements. We believe this novel approach has broad applications in various research areas involving the intersection of biomechanics and electrophysiology.


  • Automated Force Curve Methods Based Micropipette Force Sensors

    by Huiyao Shi, Si Tang, Jialin Shi, Peng Yu, Tie Yang, Chanmin Su, Lianqing Liu

    Force curve is the most important techniques for accurate measuring the stiffness, adhesion and energy dissipation. However, due to the challenges of probe-cell localization, this type of single-cell analysis tool has become a labor-intensive and time-consuming procedure. Here, we demonstrate an automatic positioning methods based on micropipette for force curves acquisition. The automation covers the detection of cells in label-free images, pre-positioning and automatic focusing of micropipette, as well as automated force curves. This new method discards silicon-based probes used in traditional AFM, and instead utilizing a transparent micropipette with an unobstructed tip as the sensor. This advancement enables accurate localization of the probe tip and cell under an optical microscope. Furthermore, during the probe positioning process, we have implemented a pre-localization method using focused laser projection. This allows for manual adjustment of the probe tip within a range of 70 micrometers, providing precise region of interests (ROI) for automatic tip focusing. Combining with the aforementioned techniques. We also demonstrate the high-precision localization and force curve acquisition of eight fixed cells on a single image. The measurement results indicate that the positioning error will not exceed 3.4 μm. Our work has effectively enhanced the efficiency of cellular mechanical measurements and holds the potential to achieve automated high-throughput single-cell analysis and drug screening.


  • Negative Photoconductive Effect for Novel Photoelectric Sensors: A Review

    by Huiyao Shi, Si Tang, Jialin Shi, Peng Yu, Tie Yang, Minglin Li, Lianqing Liu

    Photoelectronic sensors, such as phototransistors, photoelectronic vision sensors, and photoelectronic memory elements based on low-dimensional nanomaterials and their hybrid structures, have received considerable attention for their unique structure and characteristics. Most studies on photoconductance sensors focus on positive photoconductivity (PPC); however, rare cases exist in which the conductivity decreases under light exposure. Such cases are known as negative photoconductivity (NPC). The integration of NPC and PPC has garnered significant interest for its switchable memorized electron transport mechanism, thus paving a novel way for the creation of nonvolatile memories, photoelectric logic gates, and neuromorphic computing systems. To deepen our understanding of NPC-based photoelectric sensors, we focus primarily on the basic mechanics of NPC effects and explore the related materials, structures, properties, and applications. Then, we highlight the modulation techniques for achieving NPC and PPC switching and discuss the most promising logic and memory applications by integrating the NPC and PPC effects. Furthermore, this study addresses key challenges in research on nanomaterials that exhibit NPC effects, aiming to inspire further exploration of novel, high-performance, and stable photoelectric sensors.


  • Simultaneous Calibration of Axial and Lateral Radiation Forces of Ultra-High Frequency Ultrasound Acting on a Microrobot With Arbitrary Geometry

    by Jinzhe Wu, Jialin Shi, Zhaoxi Li, Peng Yu, Huiyao Shi, Si Tang, Shanshan Chen, Chunlong Fei, Chanmin Su, Lianqing Liu

    Acoustically actuated microrobots have attracted considerable attention, which have developed various geometries. These microrobots are powered through their interaction with acoustics. The use of ultrahigh-frequency (UHF) ultrasound yields a focus on the order of several microns, thus actuating microrobots with accurate, strong, and two-directional forces. However, to date no technique can simultaneously calibrate the actual axial and lateral radiation forces of UHF ultrasound above 60 MHz acting on a microrobot with arbitrary geometry. To address this issue, we present a force sensor based on a micropipette. The force sensor consists of the micropipette, microrobot with a marker, and fixed base, which calibrates the overall spring constants. By combining the two-directional displacements actuated by the axial and lateral radiation forces, we calibrated the forces with a resolution of hundreds of piconewtons. We calibrated the axial and lateral radiation forces on cylindrical and spherical microrobots with the same volume and further investigated the influences of the duty factor and excitation voltage. This method complements a crucial design link in UHF ultrasound actuating microrobots.


  • Open Access

    An integrated hinged dual-probe for co-target fast switching imaging

    by Kaixuan Wang, Jialin Shi, Tie Yang, Si Tang, Peng Yu, Huiyao Shi, Shenghang Zhai, Chanmin Su, Lianqing Liu

    The diversity of functional applications of atomic force microscopes is the key to the development of nanotechnology. However, the single probe configuration of the traditional atomic force microscope restricts the realization of different application requirements for the same target area of a single sample, and the replacement of the working probe will lead to the loss of the target area. Here, the design, simulation, fabrication, and application of a unique atomic force microscope dual-probe are presented, which consists of a pair of parallel cantilevers with a narrow gap and a U-shaped hinged probe base. The Integrated Hinged Dual-Probe (IHDP) is developed specifically for fast switching of probes working in limited space and independent and precise manipulation of each probe. The deflection signal sensing of two cantilevers is achieved simultaneously by a single laser beam, and the decoupled independent cantilever deflection signals do not interfere with each other. The switching of the working probe is achieved by a piezoelectric ceramic with a 2 µm stroke and U-shaped hinge structure, which is fast and does not require tedious and repetitive spatial position calibration. By measuring standard grid samples, IHDP exhibits excellent measurement and characterization capabilities. Finally, a working probe switching imaging experiment was conducted on solidified rat cardiomyocytes, and the experimental process and imaging results demonstrated the superiority of IHDP in switching probe scanning imaging of the same target area of a single sample. The two probes of IHDP can undergo arbitrary functionalization modifications, which helps achieve multidimensional information acquisition for a single target.

  • Axial Plane Nanoscale Measurements of Cardiomyocytes Based on Microspheres

    by Si Tang, Huiyao Shi, Peng Yu, Jialin Shi, Yuanyuan Fu, Chanmin Su, Lianqing Liu

    After eons of evolution, biological systems have developed excellent actuating methodology in micro-nano scale, which inspired the design and development of advanced microrobots. Cardiomyocytes have received extensive attention following the development of bio-syncretic robots in terms of its spontaneous contraction and high energy efficiency. However, the multipoint, high-precision synchronized, and comprehensive acquisition of the axial motion parameters of cardiomyocytes still constitutes the major factor hindering the development of quantitative control methods for bio-syncretic robots. Herein, off-focus imaging method was proposed to quantify the axial beating of cardiomyocyte. The spontaneously beating of cardiomyocytes were quantitative analyzed based on the combination of cross-correlation and off-focusing imaging. We also validated the use of the proposed SiO 2 microspheres in cardiotoxicity test. Following the administration of isoproterenol, cardiomyocytes exhibited positive inotropic and chronotropic effects. Finally, we analyzed the beating responses of individual cardiomyocytes at different locations, and we validated the feasibility of multipoint, synchronized measurements. In the future, this study can also be extended to the analysis of the motion coupling relationship between individual cardiomyocytes and cardiomyocyte clusters, thus providing a data acquisition platform for the dynamic analysis and modeling of bio-syncretic robot actuators.


  • Spatial Vibration and Displacement Measurement Through Single-Point Continuous and Interval Scanning Laser Doppler Vibrometer

    by Huiyao Shi, Jialin Shi, Yang Yang, Si Tang, Chanmin Su, Lianqing Liu

    The scanning laser Doppler vibrometer (SLDV) is an extremely valuable method for studying the dynamic properties of vibrating objects, such as those in industrial production, entomology research, and biomedical testing. The traditional SLDV method scans samples using an inclined laser, which ignores the three-dimensional (3D) information of the sample, resulting in a relatively complicated calculation process. In industrial processes and scientific research, the measured target may have a known 3D regular surface. When a structure with height information moves laterally, it causes a change in longitudinal information, which is of great benefit in the analysis of the 3D vibration and displacement information of the target. In this paper, continuous and interval scanning laser Doppler methods are proposed to expand the measuring capability of SLDV methods, based on the scanning on spherical structures. First, a spherical structure is introduced to simplify the solution to spiral vibrations. The high-precision displacement can also be calculated by fitting the circular scanning curve. Finally, the scanning method for 3D displacement measurement is experimentally validated, and the theoretical errors are demonstrated. This work provides a new methodology to realize both periodic and nonperiodic displacements in all degrees of freedom with high accuracy using a single-point SLDV, which is expected to have a long-term impact on industry vibration analysis and biological motion research. Most importantly, setting a reflector with a spherical surface on the end effector of the micro-nano robot can realize the 3D cross-scale repeated localization.