PYPeng Yu

Peng Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Yu has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-frequency symmetric dual-piezoelectric-actuated compliant microgripper with interchangeable end-effectors

    by Shitong Wang, Jialin Shi, Jinzhe Wu, Tong Yang, Hengchao Qu, Tie Yang, Peng Yu, Xiaoduo Wang, Lianqing Liu

    A symmetric dual-piezoelectric-actuated microgripper with an interchangeable end-effector is presented for micro/nano-manipulation. The design integrates a triangular amplification mechanism with a lever mechanism, achieving compactness and enhanced displacement transmission. Finite element analysis was employed to investigate the effects of hinge radius and structural angle on amplification ratio, natural frequency, and stress distribution: the amplification ratio increases monotonically with R, while natural frequency decreases with R, and maximum stress exhibits a nonlinear trend with a minimum at R≈0.85 mm; for θ, the amplification ratio and natural frequency first increase and then decrease (peaking at θ≈98° and θ≈96°, respectively), while maximum stress decreases nonlinearly with increasing θ. Subsequent stiffness optimization was conducted through threaded fixation, actuator interface reinforcement, and a stainless-steel sandwich housing. Experiments confirmed the effectiveness of the design. The prototype achieved a natural frequency of 1040 Hz and a displacement amplification ratio of 14.2, with maximum output obtained under a preload of 0.23 Nm. The interchangeable end-effectors have successfully demonstrated the capability to grip 88-μm wires, glass microtubes, and AFM probes. Compared with similar devices, the proposed microgripper maintains compact size while achieving higher dynamic performance, reducing resonance risk. These results highlight its potential for MEMS assembly, biological sample handling, and other precision manipulation tasks.


  • A Compact Mobile Robot for High Precision In Situ Surface Topography Measurement

    by Ke Xu, Jingze Liang, Liang Zhao, Peng Yu

    Conventional surface topography measurement methods often face challenges in simultaneously achieving high accuracy and field deployability, particularly for in-situ inspection of installed or large mechanical components. This article presents an autonomous measurement approach that integrates a compact mobile robot with a laser tracker to perform high-precision surface topography acquisition directly in workshop environments. The system adopts a dual-architecture design, employing an HTC VIVE system for 6-DOF closed-loop navigation and a single Spherically Mounted Reflector (SMR) for metrological data acquisition. The platform is actuated by three piezoelectric ultrasonic motors, enabling smooth, omnidirectional motion with minimal mechanical backlash. Experimental validation on a granite reference artifact demonstrates a trajectory tracking RMSE of 0.78 mm and a vertical surface measurement uncertainty of 8.4 μm. Long-term repeatability is verified through scanning experiments conducted over eight consecutive days, confirming stable performance under practical environmental conditions. The results indicate that the proposed system provides a portable and autonomous solution for surface topography measurement in flexible in-situ scenarios.

  • Open Access

    AFM Characterization of Shallow Subsurface Damage in Optical Components

    by Haichao Zhao, Liang Zhao, Qi Zhang, Yusong Li, Zhongyuan Zhu, Peng Yu, Chanmin Su, Lianqing Liu

  • Design and Fabrication of Accelerometer Based on Atomic Force Microscope Measurement Principle

    by Bin Miao, Hongji Guo, Dingyi Wang, Wen Xiong, Changkun Feng, Zhan Xu, Siyuan Fang, Hanwenyu Zhan, Peng Yu, Jiadong Li

    This paper introduces a new accelerometer based on the measurement principle of atomic force microscopy. Through the structural design of micro-cantilever arrays with different stiffness coefficients, both high resolution and large dynamic range of acceleration detection can be realized theoretically. The simulation results show that the acceleration sensor can achieve 700 ng-3 g acceleration detection. The experimental results show that the operating bandwidth of the accelerometer is 570 Hz, the background noise is 700 ng/√Hz, the bias instability is 10 ng, and the acceleration dynamic detection range is ±3 g. This scheme proves the feasibility of the accelerometer based on AFM principle, and provides a new way for the development and application of large dynamic range and high-resolution accelerometers.


  • Peak Force Torsional Resonance Microscopy for Accurate Nanoscale Characterization of In-Plane and Out-of-Plane Mechanical Properties

    by Jialin Shi, Huiyao Shi, Yongliang Yang, Peng Yu, Tie Yang, Yang Yang, Chanmin Su, Lianqing Liu

    Accurately measuring both in-plane and out-of-plane mechanical properties is essential for understanding material behavior at the nanoscale. Conventional atomic force microscopy (AFM) techniques often struggle with the coupling between vertical and lateral forces, which can distort lateral mechanical property measurements. To address this limitation, we propose a novel Peak Force Torsional Resonance (PFTR) method that combines Peak Force Tapping for precise height control with torsional resonance for in-plane property extraction. This approach effectively decouples vertical and lateral forces, significantly reducing the influence of topography and vertical interactions on lateral measurements. Additionally, we introduce a mathematical model to accurately quantify lateral properties, such as shear modulus and lateral viscosity, independent of height variations. Experimental results confirm that the PFTR method achieves high-resolution imaging of both in-plane and out-of-plane mechanical properties, offering a more accurate and reliable solution for nanoscale mechanical characterization compared to conventional AFM-based methods.


  • Multiscale Profile Characterization Based on Atomic Force Microscopy

    by Kaixuan Wang, Dingyi Wang, Jian Sun, Jialin Shi, Peng Yu, Chanmin Su, Lianqing Liu

    Accurate cross-scale measurement of surface profiles is essential in various fields such as materials science and nanotechnology. Traditional measurement techniques, like atomic force microscopy (AFM), provide high-resolution data but are limited in range, making it challenging to characterize surfaces with both fine and large-scale features comprehensively. This limitation creates a conflict in achieving precise, wide-range measurements necessary for advanced applications. To address this challenge, we propose a novel nested-feedback splicing measurement strategy that integrates AFM with an electrodynamic displacement system. This approach combines the high resolution of AFM with the extensive range capabilities of electrodynamic stages, allowing for detailed characterization across multiple scales. Our results demonstrate that the developed system significantly improves measurement accuracy, particularly in capturing detailed surface profiles over large areas. The experimental data validate the effectiveness of the proposed method, showing enhanced precision in multi-scale topographic characterization and seamless integration between fine and large-scale measurements. This advancement paves the way for more comprehensive surface analyses in scientific research and industrial applications, highlighting the system’s potential to revolutionize precision measurement technology.


  • Mechano-Electrophysiological Signals Measuring System Based on Cantilevered Micropipette Force Electric Sensor

    by Huiyao Shi, Jialin Shi, Si Tang, Peng Yu, Chanmin Su, Lianqing Liu

    Cardiomyocytes (CMs) are the contractile motors of the heart that generate the force required to pump blood into the systemic circulations. Its contractive process can be described as electrical stimulation that ultimately leads force generation (excitation–contraction coupling). Investigation of the mechanical forces and electrical signals is crucial in heart disease research and related drug assessment. Despite the long-term development of instruments for measuring mechanical or electrical signals of CMs separately, in-situ synchronous measurement of these signals of CMs still faces challenges. To address this gap, in this study, we developed cantilevered micropipette force electric sensor (CMFES) to realize mechanical and electrical signal measurements. We recorded, for the first time, the synchronous local beating, ion flow-related contraction characteristics, and action potential of CMs. The results revealed that during the late stage of Na+ influx in CMs, the cells began to contract, with a time difference of approximately 100–130 ms between the action potential and the contraction peak. Furthermore, to demonstrate the accuracy and capability of the proposed methods, we utilized CMFES to perform quantitative mechanical measurements, achieve high-resistance sealing, and record ion channel currents. In summary, our approach achieved measurement accuracy comparable to that of atomic force microscopy (AFM) and patch clamp techniques, which are currently considered the most precise technologies for mechanical and electrical measurements. We believe this novel approach has broad applications in various research areas involving the intersection of biomechanics and electrophysiology.


  • Automated Force Curve Methods Based Micropipette Force Sensors

    by Huiyao Shi, Si Tang, Jialin Shi, Peng Yu, Tie Yang, Chanmin Su, Lianqing Liu

    Force curve is the most important techniques for accurate measuring the stiffness, adhesion and energy dissipation. However, due to the challenges of probe-cell localization, this type of single-cell analysis tool has become a labor-intensive and time-consuming procedure. Here, we demonstrate an automatic positioning methods based on micropipette for force curves acquisition. The automation covers the detection of cells in label-free images, pre-positioning and automatic focusing of micropipette, as well as automated force curves. This new method discards silicon-based probes used in traditional AFM, and instead utilizing a transparent micropipette with an unobstructed tip as the sensor. This advancement enables accurate localization of the probe tip and cell under an optical microscope. Furthermore, during the probe positioning process, we have implemented a pre-localization method using focused laser projection. This allows for manual adjustment of the probe tip within a range of 70 micrometers, providing precise region of interests (ROI) for automatic tip focusing. Combining with the aforementioned techniques. We also demonstrate the high-precision localization and force curve acquisition of eight fixed cells on a single image. The measurement results indicate that the positioning error will not exceed 3.4 μm. Our work has effectively enhanced the efficiency of cellular mechanical measurements and holds the potential to achieve automated high-throughput single-cell analysis and drug screening.


  • Negative Photoconductive Effect for Novel Photoelectric Sensors: A Review

    by Huiyao Shi, Si Tang, Jialin Shi, Peng Yu, Tie Yang, Minglin Li, Lianqing Liu

    Photoelectronic sensors, such as phototransistors, photoelectronic vision sensors, and photoelectronic memory elements based on low-dimensional nanomaterials and their hybrid structures, have received considerable attention for their unique structure and characteristics. Most studies on photoconductance sensors focus on positive photoconductivity (PPC); however, rare cases exist in which the conductivity decreases under light exposure. Such cases are known as negative photoconductivity (NPC). The integration of NPC and PPC has garnered significant interest for its switchable memorized electron transport mechanism, thus paving a novel way for the creation of nonvolatile memories, photoelectric logic gates, and neuromorphic computing systems. To deepen our understanding of NPC-based photoelectric sensors, we focus primarily on the basic mechanics of NPC effects and explore the related materials, structures, properties, and applications. Then, we highlight the modulation techniques for achieving NPC and PPC switching and discuss the most promising logic and memory applications by integrating the NPC and PPC effects. Furthermore, this study addresses key challenges in research on nanomaterials that exhibit NPC effects, aiming to inspire further exploration of novel, high-performance, and stable photoelectric sensors.