KSKaoru Sato

Kaoru Sato

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kaoru Sato has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • H. Noguchi

    Safety Administration Department , Japan Atomic Energy Agency , 4-49 Muramatsu, Tokai-mura, Naka-gun, Ibaraki-ken 319-1184 , Japan

    2 shared publications
  • K. Saito

    Nuclear Science and Engineering Directorate , Japan Atomic Energy Agency , 2-4 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 , Japan

    2 shared publications
  • S. Koga

    Nuclear Science and Engineering Directorate , Japan Atomic Energy Agency , 2-4 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 , Japan

    2 shared publications
  • Y. Emoto

    Fujita Health University , School of Medicine, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake-shi, Aichi-ken 470-1192 , Japan

    2 shared publications
  • Yasushi Katsunuma

    Department of Radiological Technology, Tokai University Hospital

    2 shared publications
  • A. Endo

    Nuclear Science and Engineering Directorate , Japan Atomic Energy Agency , 2-4 Shirakata-Shirane, Tokai-mura, Naka-gun, Ibaraki-ken 319-1195 , Japan

    1 shared publication

Latest Publications

  • Open Access

    Age-dependent evaluation of organ and effective doses in pediatric full-spine radiography: influence of anteroposterior and posteroanterior projection and copper filtration using Monte Carlo simulation

    by Yasushi Katsunuma, Kaoru Sato

    Background: Repeated full-spine radiography for scoliosis follow-up in children results in increased radiation exposure, especially to anterior radiosensitive organs. Optimizing projection direction and beam filtration is essential for dose reduction. Objective: To quantitatively evaluate the age-dependent effects of anteroposterior (AP) and posteroanterior (PA) projections, with and without a 0.1-mm copper filter, on organ and effective doses in pediatric full-spine radiography. Materials and methods: Monte Carlo simulations were performed using the Particle and Heavy Ion Transport code System with 5-, 10-, and 15-year-old female hybrid phantoms. Full-spine radiography from the first cervical vertebra to both femoral heads was modeled under AP and PA conditions, with or without copper filtration. Organ doses were calculated, with active bone marrow and bone surface evaluated using the “International Commission on Radiological Protection Publication 116” dose response functions. Percentage depth dose analysis was performed to assess the effect of body thickness. Results: PA projection markedly reduced doses to anterior radiosensitive organs, with maximum reductions of approximately 93% for the breast (AP/PA ratio 14) and over 80% for the thyroid. Copper filtration provided additional reductions of 15–19% in AP and 5–6% in PA. In contrast, dose increases were observed in posterior and deep-seated organs such as the kidneys and active bone marrow. Effective dose was reduced by about half with PA and further decreased with copper filtration. Conclusion: PA projection and copper filtration are effective strategies for reducing radiation exposure to anterior radiosensitive organs and lowering effective dose in pediatric full-spine radiography. However, dose increases in deep-seated organs were also observed, highlighting the need for protocol optimization according to patient age and organ location. Graphical


  • Open Access

    A novel preview control for MLD models and its neural network approximation for real‐time implementation: Application to semi‐active vibration control of a vehicle suspension

    by Kaoru Sato, Kazuhiko Hiramoto

    Advances in image processing technology have made it possible to measure the surface shape of the road ahead while driving. A new semi‐active suspension control method considering the forward road surface shape is proposed. A vehicle model equipped with a semi‐active suspension can be expressed as an mixed logical dynamical model. When the shape of the road ahead can be measured, the information on future disturbances is available before the vehicle undergoes. In this paper, the finite time optimization problem for the mixed logical dynamical model is formulated to consider the future disturbances as a mixed integer quadratic programming problem in the same way as the conventional control problem without future disturbance. However, the mixed integer quadratic programming problem is hard to obtain the control action within the control cycle period required in the real‐time vibration control with general computers for vehicles. In this paper, the reduction of the computational load is achieved by constructing an approximation function of the designed controller. A neural network is adopted for the approximation. The performance evaluation of the proposed method is evaluated by simulations. In the simulation study, the proposed method achieves better ride comfort with the equivalent suspension stroke compared to the traditional methods.


  • Open Access

    Brain partial volume correction with point spreading function reconstruction in high-resolution digital PET: comparison with an MR-based method in FDG imaging

    by Masanobu Ibaraki, Keisuke Matsubara, Yuki Shinohara, Miho Shidahara, Kaoru Sato, Hiroyuki Yamamoto, Toshibumi Kinoshita

    Objective: In quantitative positron emission tomography (PET) of the brain, partial volume effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half maximum [FWHM]) is a primary source of error in the measurement of tracer uptake, especially in small structures such as the cerebral cortex (typically < 3 mm thickness). The aim of this study was to evaluate the partial volume correction (PVC) performance of point spread function-incorporated reconstruction (PSF reconstruction) in combination with the latest digital PET scanner. This evaluation was performed through direct comparisons with magnetic resonance imaging (MR)-based PVC (used as a reference method) in a human brain study. Methods: Ten healthy subjects underwent brain 18F-FDG PET (30-min acquisition) on a digital PET/CT system (Siemens Biograph Vision, 3.5-mm FWHM scanner resolution at the center of the field of view) and anatomical T1-weighted MR imaging for MR-based PVC. PSF reconstruction was applied with a wide range of iterations (4 to 256; 5 subsets). FDG uptake in the cerebral cortex was evaluated using the standardized uptake value ratio (SUVR) and compared between PSF reconstruction and MR-based PVC. Results: Cortical structures were visualized by PSF reconstruction with several tens of iterations and were anatomically well matched with the MR-derived cortical segments. Higher numbers of iterations resulted in higher cortical SUVRs, which approached those of MR-based PVC (1.76), although even with the maximum number of iterations they were still smaller by 16% (1.47), corresponding to approximately 1.5-mm FWHM of the effective spatial resolution. Conclusion: With the latest digital PET scanner, PSF reconstruction can be used as a PVC technique in brain PET, albeit with suboptimal resolution recovery. A relative advantage of PSF reconstruction is that it can be applied not only to cerebral cortical regions, but also to various small structures such as small brain nuclei that are hardly visualized on anatomical T1-weighted imaging, and thus hardly recovered by MR-based PVC.


  • Open Access

    Organ Dose Reconstruction Applicable for a Japanese Nuclear Worker Cohort: J-EPISODE

    by Hiroshige Furuta, Kaoru Sato, Akemi Nishide, Shin’iChi Kudo, Shin Saigusa

    An evaluation of cancer risk based on organ-absorbed dose is underway for the Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE), which has analyzed health effects in association with radiation exposure evaluated with the personal dose equivalent H p(10). Although the concept of effective dose and its operational definition of H p(10) are widely used for radiological protection purposes, effective dose is not recommended for epidemiological evaluation. Organ-absorbed dose was instead adopted for the IARC 15-Country Collaborative study (15-Country study), the International Nuclear Workers Study (INWORKS), the Mayak worker study, and the Life Span Study (LSS) of atomic bomb survivors. The reconstruction method in J-EPISODE followed in principle the approach adopted in the 15-Country Study. As part of the approach of J-EPISODE, a conversion factor from photon dosimeter reading to air kerma was developed using dosimeter response data, which were measured by the experiment using an anthropomorphic phantom, and it was confirmed that the 15-Country study’s assumption of photon energy and geometry distribution in a work environment applied to Japanese nuclear workers. This article focuses on a method for reconstructing the conversion factor from photon dosimeter reading to organ-absorbed photon dose for a Japanese nuclear worker cohort. The model for estimating the conversion factor was defined under the assumption of a lognormal distribution from three concerned bias factors: (1) a dosimeter reading per air kerma, i.e., dosimeter response; (2) an organ-absorbed dose per air kerma; and (3) a factor relating to the differences in dose concepts and calibration practices between the roentgen dosimeter era and the present. Dosimeter response data were cited from the companion paper. Data on organ-absorbed photon dose per air kerma were estimated using a voxel phantom with the average Japanese adult male height and weight. The bias factor for the recorded dose in the roentgen era was defined, considering the backscatter radiation from the human body. The estimated values of organ-absorbed photon dose per air kerma were almost the same as those in ICRP Publication 116, revealing that the effect of differences in body size was almost negligible. The conversion factors from dosimeter reading to organ-absorbed dose were estimated by period (the roentgen era or from then), nuclear facility type (nuclear power plant or other), dosimeter type, and tissue or organ. The estimated conversion factors ranged from 0.7 to 0.9 (Gy Sv−1). The estimated cumulative organ-absorbed photon dose for the participants of J-EPISODE demonstrated that organ-absorbed dose values were approximately 0.8 times the recorded doses if neglecting dose-unit differences. J-EPISODE reconstructed an organ-absorbed dose conversion factor and will evaluate the risk of cancer mortality and morbidity using the organ-absorbed dose in the future.


  • The contemporary JAEA Japanese voxel phantoms

    by Kaoru Sato, Fumiaki Takahashi

    Average adult Japanese male (JM-103 phantom) and female (JF-103 phantom) voxel (volume pixel) phantoms were newly constructed by modifying the JM and JF phantoms previously developed at Japan Atomic Energy Agency. The JM-103 and JF-103 have average characteristics with respect to organ masses and body sizes. Their tissue segmentations were based on International Commission on Radiological Protection (ICRP) Publication 103. The anatomical and dosimetric characteristics of JM-103 and JF-103 were compared with those of ICRP adult reference male (AM phantom) and female (AF phantoms) phantoms. This study discusses their anatomical and dosimetric characteristics, and applications to the dose assessment of the atomic bomb survivors.


  • WAZA-ARI: computational dosimetry system for X-ray CT examinations II: Development of web-based system

    by Nobuhiko Ban, Fumiaki Takahashi, Koji Ono, Takayuki Hasegawa, Takayasu Yoshitake, Yasushi Katsunuma, Kaoru Sato, Akira Endo, Michiaki Kai

    A web-based dose computation system, WAZA-ARI, is being developed for patients undergoing X-ray CT examinations. The system is implemented in Java on a Linux server running Apache Tomcat. Users choose scanning options and input parameters via a web browser over the Internet. Dose coefficients, which were calculated in a Japanese adult male phantom (JM phantom) are called upon user request and are summed over the scan range specified by the user to estimate a normalised dose. Tissue doses are finally computed based on the radiographic exposure (mA s) and the pitch factor. While dose coefficients are currently available only for limited CT scanner models, the system has achieved a high degree of flexibility and scalability without the use of commercial software.


  • Sub-nanometre elemental analysis of Cu cluster in Fe-Cu-Ni alloy using aberration corrected STEM-EDS

    by H. Nakamichi, K. Yamada, K. Sato

    In order to understand the mechanism of Cu clustering and Ni effects on Cu clusters, a sub-nano scale structural and elemental analysis of Cu-bearing steels was carried out through an aberration corrected scanning transmission electron microscope. Based on systematic observation condition adjustment by changing the electron scattered angle, we adopted an inner scattered semi angle of between 50 and 70 mrad for the scanning transmission electron microscope energy dispersive X-ray spectroscopy analysis. Under this condition, Cu precipitates such as 9R are clearly recognized through atomic scale scanning transmission electron microscope annular dark field images. Cu clusters, before transforming to 9R, are detected on the dislocation and have a periodical strain field. Ni enrichment is also observed in the vicinity of Cu clusters. Considering these enrichment phenomena of Cu and Ni, it is found that Cu diffuses rapidly through dislocation, while at the same time, Ni enrichment occurs by ejection from Cu clusters and forms a shell structure.


  • Analysis of effects of posture on organ doses by internal photon emitters using voxel phantoms

    by Kaoru Sato, Akira Endo

    In order to clarify the effects of posture on absorbed doses in organs due to internal exposures, specific absorbed fractions (SAFs) for monoenergetic photons from 0.01 to 4 MeV were calculated using two Japanese adult male phantoms, JM2 (upright) and JM (supine), whose designs were based on CT images of two postures obtained from the same person. Differences in the SAFs of JM2 and JM are within a factor of 2 in most cases although significant differences in SAFs exist in several combinations of source and target organs for low energy photons. Organ doses due to photons from the intake of unit activity of eight radionuclides (Ba-126, Ba-128, Ba-133, Cs-130, Cs-131, W-178, W-179 and W-190) with different biokinetics and decay characteristics were calculated from the SAFs of JM2 and JM. It was found that the organ doses in the testes, bone marrow, lower large intestine wall, lungs and stomach wall, which are important for calculating effective dose, in the two postures roughly agree, the maximum difference being 14%. These results indicate that the impact of posture on the organ doses and effective doses from internal photon emitters is not significant.


  • Development of a voxel phantom of Japanese adult male in upright posture

    by K. Sato, H. Noguchi, A. Endo, Y. Emoto, S. Koga, K. Saito

    A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spine and lower abdomen and the locations of several organs such as kidneys, liver and stomach between the two phantoms. Specific absorbed fractions (SAFs) for 24 target and 11 sources organs were calculated for monoenergetic photon ranging from 0.01 to 4 MeV. It was found that the SAFs for the kidneys as source organ and the lower large intestine wall as target organ in JM2 were significantly higher than those in JM for all photon energies. The differences of the SAFs between the two phantoms were attributed to the differences in the organ distance and organ geometry depending on the posture.