Age-dependent evaluation of organ and effective doses in pediatric full-spine radiography: influence of anteroposterior and posteroanterior projection and copper filtration using Monte Carlo simulation
Open Access
- 11 December 2025
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (3) , 603-617
Abstract
Background: Repeated full-spine radiography for scoliosis follow-up in children results in increased radiation exposure, especially to anterior radiosensitive organs. Optimizing projection direction and beam filtration is essential for dose reduction. Objective: To quantitatively evaluate the age-dependent effects of anteroposterior (AP) and posteroanterior (PA) projections, with and without a 0.1-mm copper filter, on organ and effective doses in pediatric full-spine radiography. Materials and methods: Monte Carlo simulations were performed using the Particle and Heavy Ion Transport code System with 5-, 10-, and 15-year-old female hybrid phantoms. Full-spine radiography from the first cervical vertebra to both femoral heads was modeled under AP and PA conditions, with or without copper filtration. Organ doses were calculated, with active bone marrow and bone surface evaluated using the “International Commission on Radiological Protection Publication 116” dose response functions. Percentage depth dose analysis was performed to assess the effect of body thickness. Results: PA projection markedly reduced doses to anterior radiosensitive organs, with maximum reductions of approximately 93% for the breast (AP/PA ratio 14) and over 80% for the thyroid. Copper filtration provided additional reductions of 15–19% in AP and 5–6% in PA. In contrast, dose increases were observed in posterior and deep-seated organs such as the kidneys and active bone marrow. Effective dose was reduced by about half with PA and further decreased with copper filtration. Conclusion: PA projection and copper filtration are effective strategies for reducing radiation exposure to anterior radiosensitive organs and lowering effective dose in pediatric full-spine radiography. However, dose increases in deep-seated organs were also observed, highlighting the need for protocol optimization according to patient age and organ location. GraphicalKeywords
Funding Information
- Tokai University, Isehara Campus
This publication has 33 references indexed in Scilit:
- Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluationJournal of Applied Clinical Medical Physics, 2020
- Lowered dose full-spine radiography in pediatric patients with idiopathic scoliosisEuropean Spine Journal, 2018
- AP versus PA positioning in lumbar spine computed radiography: Image quality and individual organ dosesRadiography, 2015
- Conversion coefficients for determining organ doses in paediatric spine radiographyPediatric Radiology, 2014
- ICRP Publication 121: Radiological Protection in Paediatric Diagnostic and Interventional RadiologyAnnals of the ICRP, 2013
- Epidemiology of adolescent idiopathic scoliosisJournal of Children's Orthopaedics, 2013
- Copper filtration in pediatric digital X-ray imaging: its impact on image quality and doseRadiological Physics and Technology, 2011
- Conversion Coefficients for Radiological Protection Quantities for External Radiation ExposuresAnnals of the ICRP, 2010
- Realistic reference phantoms: An ICRP/ICRU joint effortAnnals of the ICRP, 2009
- Preface, Executive Summary and GlossaryAnnals of the ICRP, 2007