Iris de Krom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Iris de Krom has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Luuk Meijer
Van Swinden Laboratorium B.V. (VSL)
2 shared publications - Adriaan M. H. van der Veen
Van Swinden Laboratorium, Department of Chemistry, Thijsseweg 11, 2629 JA Delft, The Netherlands, The Netherlands
1 shared publication - Annarita Baldan
Department of Chemistry, Viscosity, Pressure and Mass, VSL, Thijsseweg 11, Delft, 2629JA, NETHERLANDS
1 shared publication Dita Heikens
Department of Chemistry, Viscosity, Pressure and Mass, VSL, Thijsseweg 11, Delft , 2629JA, NETHERLANDS
1 shared publicationEmma Henderson
1 shared publicationEvtim Efremov
Van Swinden Laboratorium B.V. (VSL)
1 shared publication
Latest Publications
- Open Access
- 14 April 2026
- Published by CERN in Open Research Europe
- Vol. 6, 112
New primary reference materials for gas composition for carbon capture, utilisation and storage and how they support industry and meet the technical specifications of European manufacturers
This work describes the development and validation of new Primary Reference Materials (PRMs) for trace impurities in carbon dioxide (CO 2), addressing a key metrological gap for carbon capture, utilisation, and storage (CCUS) applications. CO 2 streams captured from industrial sources inevitably contain impurities such as water, sulfur oxides, nitrogen oxides, hydrogen, and hydrocarbons. Accurate and traceable quantification of these species is essential to protect transport infrastructure, ensure compliance with project specifications, and enable safe long-term geological storage. International and project-specific guidelines, including ISO/TR 27913, Porthos, and Northern Lights, define stringent impurity limits, underscoring the need for reliable gas standards for calibration and validation of analytical instruments. Binary and multi-component PRMs were prepared by VSL, NPL, CMI, IPQ, and SINTEF ER using ISO 6142-1 gravimetric methods. The mixtures covered sulfur dioxide, hydrogen sulfide, nitrogen dioxide, nitrous oxide, water, dimethyl sulfide, ethanol, and non-condensable gases (N 2, Ar, H 2, O 2, CH 4, and CO) at amount fractions relevant to CCUS specifications. In parallel, dynamic preparation systems and a portable trace gas generator were validated as alternative approaches for producing low-level mixtures of reactive species such as ammonia. PRM stability was investigated over a two-year period. Sulfur dioxide, hydrogen sulfide, dimethyl sulfide, ethanol, and nitrous oxide demonstrated stability within their expanded uncertainties. In contrast, sulfur dioxide, nitrogen dioxide, and nitric oxide in multi-component mixtures exhibited significant degradation, indicating pronounced reactivity and wall effects. Dynamic dilution systems developed by VSL and NPL produced mixtures consistent with static PRMs within 1–5%, while the portable trace gas generator achieved ammonia generation in CO 2 with a relative uncertainty of approximately 2%. These results establish a robust metrological basis for impurity analysis in CO 2. The PRMs developed within MetCCUS provide traceable calibration capabilities aligned with European CO 2 quality specifications, supporting reliable monitoring and safe operation of CCUS infrastructure.
- 14 April 2026
- Published by CERN in Open Research Europe
- Vol. 6, 112
Open AccessNew primary reference materials for gas composition for carbon capture, utilisation and storage and how they support industry and meet the technical specifications of European manufacturers
This work describes the development and validation of new Primary Reference Materials (PRMs) for trace impurities in carbon dioxide (CO 2), addressing a key metrological gap for carbon capture, utilisation, and storage (CCUS) applications. CO 2 streams captured from industrial sources inevitably contain impurities such as water, sulfur oxides, nitrogen oxides, hydrogen, and hydrocarbons. Accurate and traceable quantification of these species is essential to protect transport infrastructure, ensure compliance with project specifications, and enable safe long-term geological storage. International and project-specific guidelines, including ISO/TR 27913, Porthos, and Northern Lights, define stringent impurity limits, underscoring the need for reliable gas standards for calibration and validation of analytical instruments. Binary and multi-component PRMs were prepared by VSL, NPL, CMI, IPQ, and SINTEF ER using ISO 6142-1 gravimetric methods. The mixtures covered sulfur dioxide, hydrogen sulfide, nitrogen dioxide, nitrous oxide, water, dimethyl sulfide, ethanol, and non-condensable gases (N 2, Ar, H 2, O 2, CH 4, and CO) at amount fractions relevant to CCUS specifications. In parallel, dynamic preparation systems and a portable trace gas generator were validated as alternative approaches for producing low-level mixtures of reactive species such as ammonia. PRM stability was investigated over a two-year period. Sulfur dioxide, hydrogen sulfide, dimethyl sulfide, ethanol, and nitrous oxide demonstrated stability within their expanded uncertainties. In contrast, sulfur dioxide, nitrogen dioxide, and nitric oxide in multi-component mixtures exhibited significant degradation, indicating pronounced reactivity and wall effects. Dynamic dilution systems developed by VSL and NPL produced mixtures consistent with static PRMs within 1–5%, while the portable trace gas generator achieved ammonia generation in CO 2 with a relative uncertainty of approximately 2%. These results establish a robust metrological basis for impurity analysis in CO 2. The PRMs developed within MetCCUS provide traceable calibration capabilities aligned with European CO 2 quality specifications, supporting reliable monitoring and safe operation of CCUS infrastructure.
- Open Access
- 17 February 2026
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 352
Characterization of HCl Primary Reference Gas Standards for Emission Monitoring
Hydrogen chloride (HCl) is a key acidic pollutant emitted by waste-to-energy plants, as well as in industrial processes such as cement manufacturing and fossil fuel combustion. Due to its harmful impact on human health and the environment, strict emission limits are enforced under regulations like the European Industrial Emissions Directive (2010/75/EU), revised in 2024, which require regular monitoring of HCl. In Europe, HCl emissions are typically monitored using wet-chemical methods in accordance with EN 1911. These methods exhibit high uncertainty at concentrations below 10 mg m - ³, the EU’s daily average emission limit, prompting the exploration of more accurate alternatives. Optical gas analysers, already approved by the U.S. Environmental Protection Agency, offer a promising alternative with lower measurement uncertainty. These instruments require calibration with reference gas standards of established metrological traceability. To meet this requirement, VSL employed an optical gas analyser to investigate key factors influencing the development of primary reference materials (PRMs) with HCl. The study focused on stability, adsorption behaviour, and pressure dependence of HCl PRMs. As a result, VSL successfully produced PRMs for HCl in high-pressure cylinders, achieving amount fractions as low as 5 µmol mol -1 in nitrogen (approximately 10 mg m - ³) with an expanded relative uncertainty of 3% ( k = 2). These PRMs are essential for ensuring accurate and reliable calibration of optical gas analysers used in emission monitoring applications.
- 17 February 2026
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 352
Open AccessCharacterization of HCl Primary Reference Gas Standards for Emission Monitoring
Hydrogen chloride (HCl) is a key acidic pollutant emitted by waste-to-energy plants, as well as in industrial processes such as cement manufacturing and fossil fuel combustion. Due to its harmful impact on human health and the environment, strict emission limits are enforced under regulations like the European Industrial Emissions Directive (2010/75/EU), revised in 2024, which require regular monitoring of HCl. In Europe, HCl emissions are typically monitored using wet-chemical methods in accordance with EN 1911. These methods exhibit high uncertainty at concentrations below 10 mg m - ³, the EU’s daily average emission limit, prompting the exploration of more accurate alternatives. Optical gas analysers, already approved by the U.S. Environmental Protection Agency, offer a promising alternative with lower measurement uncertainty. These instruments require calibration with reference gas standards of established metrological traceability. To meet this requirement, VSL employed an optical gas analyser to investigate key factors influencing the development of primary reference materials (PRMs) with HCl. The study focused on stability, adsorption behaviour, and pressure dependence of HCl PRMs. As a result, VSL successfully produced PRMs for HCl in high-pressure cylinders, achieving amount fractions as low as 5 µmol mol -1 in nitrogen (approximately 10 mg m - ³) with an expanded relative uncertainty of 3% ( k = 2). These PRMs are essential for ensuring accurate and reliable calibration of optical gas analysers used in emission monitoring applications.
- Open Access
- 10 January 2025
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 92
Quality of biogenic carbon dioxide stream from biogas plants including analytical method development
- 10 January 2025
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 92
Open AccessQuality of biogenic carbon dioxide stream from biogas plants including analytical method development
- Open Access
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Metrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Open AccessMetrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.