Annarita Baldan
Research Subjects
Annarita Baldan has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Matthias Richter
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
2 shared publications - Olaf Wilke
Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, Berlin, Berlin, 12205, GERMANY
2 shared publications - Adriaan M. H. van der Veen
Van Swinden Laboratorium, Department of Chemistry, Thijsseweg 11, 2629 JA Delft, The Netherlands, The Netherlands
1 shared publication Christophe Sutour
LNE, 75015 Paris, France
1 shared publicationClaire Kaiser
LNE, 75015 Paris, France
1 shared publication- Dirk Tuma
Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12200 Berlin, Germany
1 shared publication
Latest Publications
- Open Access
- 12 March 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 224
Primary gas standards for the determination of sulfur-based impurities at trace level in hydrogen
- 12 March 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 224
Open AccessPrimary gas standards for the determination of sulfur-based impurities at trace level in hydrogen
- Open Access
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Metrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Open AccessMetrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (15) , 3014-3022
Zero gas reference standards
High purity nitrogen or air, often referred to as zero gas, is essential for calibrating instrumentation used in a wide variety of measurements, such as air quality monitoring.
- 6 April 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (15) , 3014-3022
Zero gas reference standards
High purity nitrogen or air, often referred to as zero gas, is essential for calibrating instrumentation used in a wide variety of measurements, such as air quality monitoring.