Marcella Matos Cordeiro Borges
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcella Matos Cordeiro Borges has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Arnaldo César Pereira
Universidade Federal de São João del-Rei
2 shared publications - Daniela Nunes da Silva
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Scarlat Ohanna Dávila da Trindade
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Thaís Cristina de Oliveira Cândido
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Thiago Gabry Barbosa
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Aline Klassen
Instituto de Ciências Ambientais, Químicas e Farmacêuticas, Universidade Federal de São Paulo (UNIFESP), Campus Diadema, Rua São Nicolau, 210, Centro, Diadema 09913-030, SP, Brazil
1 shared publication
Latest Publications
- Open Access
Influence of Surface Treatments on the Electrochemical Performance of Lab-Made 3D-Printed Electrodes
This study investigated the effect of surface treatments on the electrochemical performance of 3D-printed electrodes for versatile applications. The conductive filament was obtained from a mixture of polylactic acid (PLA) and carbon black (CB) at a 7:3 ratio (PLA/CB) dispersed in acetic acid and dichloroethane (3:1) medium. The treatments used were HNO3, NaOH, DMF (immersion for 30, 30, and 15 min, respectively), and electrochemical activation (amperometry 150 s, 1.8 V). In general, the treatments allow greater exposure of the conductive material and active sites present on the sensor surface. This was confirmed using cyclic voltammetry and electrochemical impedance spectroscopy. The analyses were conducted with a 0.10 M KCl solution containing the redox pair ferricyanide/ferrocyanide 5.00 mmol L−1. Based on the results obtained, the electroactive area, kinetic constant and resistance to electron transfer were determined for each treatment. The treatment in basic medium stood out as the treatment that was most appropriate for the device used in this work. The device was also tested for its potential in the analysis of acetaminophen, demonstrating satisfactory results permitting the application of 3D-SBasic in the analysis of acetaminophen.
Open AccessInfluence of Surface Treatments on the Electrochemical Performance of Lab-Made 3D-Printed Electrodes
This study investigated the effect of surface treatments on the electrochemical performance of 3D-printed electrodes for versatile applications. The conductive filament was obtained from a mixture of polylactic acid (PLA) and carbon black (CB) at a 7:3 ratio (PLA/CB) dispersed in acetic acid and dichloroethane (3:1) medium. The treatments used were HNO3, NaOH, DMF (immersion for 30, 30, and 15 min, respectively), and electrochemical activation (amperometry 150 s, 1.8 V). In general, the treatments allow greater exposure of the conductive material and active sites present on the sensor surface. This was confirmed using cyclic voltammetry and electrochemical impedance spectroscopy. The analyses were conducted with a 0.10 M KCl solution containing the redox pair ferricyanide/ferrocyanide 5.00 mmol L−1. Based on the results obtained, the electroactive area, kinetic constant and resistance to electron transfer were determined for each treatment. The treatment in basic medium stood out as the treatment that was most appropriate for the device used in this work. The device was also tested for its potential in the analysis of acetaminophen, demonstrating satisfactory results permitting the application of 3D-SBasic in the analysis of acetaminophen.
- Open Access
3D-Printed Electrochemical Sensors: A Comprehensive Review of Clinical Analysis Applications
Three-dimensional printing technology has emerged as a versatile and cost-effective alternative for the fabrication of electrochemical sensors. To enhance sensor sensitivity and biocompatibility, a diverse range of biocompatible and conductive materials can be employed in these devices. This allows these sensors to be modified to detect a wide range of analytes in various fields. 3D-printed electrochemical sensors have the potential to play a pivotal role in personalized medicine by enabling the real-time monitoring of metabolite and biomarker levels. These data can be used to personalize treatment strategies and optimize patient outcomes. The portability and low-cost nature of 3D-printed electrochemical sensors make them suitable for point-of-care (POC) diagnostics. These tests enable rapid and decentralized analyses, aiding in diagnosis and treatment decisions in resource-limited settings. Among the techniques widely reported in the literature for 3D printing, the fused deposition modeling (FDM) technique is the most commonly used for the development of electrochemical devices due to the easy accessibility of equipment and materials. Focusing on the FDM technique, this review explores the critical factors influencing the fabrication of electrochemical sensors and discusses potential applications in clinical analysis, while acknowledging the challenges that need to be overcome for its effective adoption.
Open Access3D-Printed Electrochemical Sensors: A Comprehensive Review of Clinical Analysis Applications
Three-dimensional printing technology has emerged as a versatile and cost-effective alternative for the fabrication of electrochemical sensors. To enhance sensor sensitivity and biocompatibility, a diverse range of biocompatible and conductive materials can be employed in these devices. This allows these sensors to be modified to detect a wide range of analytes in various fields. 3D-printed electrochemical sensors have the potential to play a pivotal role in personalized medicine by enabling the real-time monitoring of metabolite and biomarker levels. These data can be used to personalize treatment strategies and optimize patient outcomes. The portability and low-cost nature of 3D-printed electrochemical sensors make them suitable for point-of-care (POC) diagnostics. These tests enable rapid and decentralized analyses, aiding in diagnosis and treatment decisions in resource-limited settings. Among the techniques widely reported in the literature for 3D printing, the fused deposition modeling (FDM) technique is the most commonly used for the development of electrochemical devices due to the easy accessibility of equipment and materials. Focusing on the FDM technique, this review explores the critical factors influencing the fabrication of electrochemical sensors and discusses potential applications in clinical analysis, while acknowledging the challenges that need to be overcome for its effective adoption.
- Open Access
- 30 November 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (23) , 15994
Short-End Injection Capillary Electrophoresis and Multivariate Analysis for Simultaneous Determination of Heavy Metals in Passiflora incarnata Tea
An ultra-fast method for the simultaneous determination of heavy metals in Passiflora incarnata tea by capillary electrophoresis (CE) using a short-end injection combined with multivariate analysis was proposed. Separation was conducted by hydrodynamic injection (5 s at 0.5 psi) using the short-end injection procedure in a fused uncoated silica capillary (50 cm total length, 10.2 cm effective length, 50 µm i.d.) with separation time less than 2 min. An indirect UV detection at 214 nm was employed by using imidazole as a chromophore. The buffer used was 6 mmol/L hydroxybutyric acid (HIBA). The optimum conditions by full factorial with a central point were achieved by 18-crown-6 concentration (23.3 mmol L−1), voltage (+11.4 kV), methanol concentration (3.8%), and temperature (20 °C). The method showed good linearity (R2 > 0.998) for both Cd and Pb, inter-day precision of less than 14.49%, and an adequate limit of quantification only for Cd (LOQ < 0.5 µg mL−1 for Cd) based on the US Pharmacopeial Convention limit requirements for elemental impurities. After method validation, the method was applied to Passiflora incarnata tea samples from a local market. Furthermore, the developed method showed great potential for the determination of metals in other samples with proper sample preparation procedures.
- 30 November 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (23) , 15994
Open AccessShort-End Injection Capillary Electrophoresis and Multivariate Analysis for Simultaneous Determination of Heavy Metals in Passiflora incarnata Tea
An ultra-fast method for the simultaneous determination of heavy metals in Passiflora incarnata tea by capillary electrophoresis (CE) using a short-end injection combined with multivariate analysis was proposed. Separation was conducted by hydrodynamic injection (5 s at 0.5 psi) using the short-end injection procedure in a fused uncoated silica capillary (50 cm total length, 10.2 cm effective length, 50 µm i.d.) with separation time less than 2 min. An indirect UV detection at 214 nm was employed by using imidazole as a chromophore. The buffer used was 6 mmol/L hydroxybutyric acid (HIBA). The optimum conditions by full factorial with a central point were achieved by 18-crown-6 concentration (23.3 mmol L−1), voltage (+11.4 kV), methanol concentration (3.8%), and temperature (20 °C). The method showed good linearity (R2 > 0.998) for both Cd and Pb, inter-day precision of less than 14.49%, and an adequate limit of quantification only for Cd (LOQ < 0.5 µg mL−1 for Cd) based on the US Pharmacopeial Convention limit requirements for elemental impurities. After method validation, the method was applied to Passiflora incarnata tea samples from a local market. Furthermore, the developed method showed great potential for the determination of metals in other samples with proper sample preparation procedures.