Thaís Cristina de Oliveira Cândido
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thaís Cristina de Oliveira Cândido has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arnaldo César Pereira
Universidade Federal de São João del-Rei
9 shared publications - Daniela Nunes da Silva
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
6 shared publications - Lucas Franco Ferreira
Institute of Science and Technology, Federal University of the Jequitinhonha and Mucuri Valleys (UFVJM), Diamantina 39100-000, MG, Brazil
3 shared publications - Marcella Matos Cordeiro Borges
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Scarlat Ohanna Dávila da Trindade
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications - Sthephane Pereira de Oliveira
Natural Sciences Department, Federal University of São João del Rei, 74 Praça Dom Helvécio, São João del Rei 36301-160, MG, Brazil
2 shared publications
Latest Publications
- 9 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Electrodes for the Voltammetric Determination of Ciprofloxacin in Pharmaceutical and Water Samples
This study reports a laser-induced graphene (LIG) electrode as a simple platform for the determination of ciprofloxacin (CPX). LIG was fabricated by laser scribing a Kapton® polyimide tape affixed to a ceramic substrate. Under optimized conditions, phosphate buffer as supporting electrolyte (0.10 mol L⁻¹, pH 7.0), and differential pulse voltammetry (pulse amplitude 60 mV, scan rate 30 mV s⁻¹), the method delivered a linear response from 8.3 to 166.7 μmol L⁻¹, with limits of detection and quantification of 2.5 and 8.3 μmol L⁻¹, respectively. The procedure was successfully applied to a pharmaceutical formulation and river water, yielding recoveries of 92.93–110% with good precision, thereby demonstrating the robustness of the method. The proposed LIG sensor is a cost-effective and sustainable alternative for environmental and quality control monitoring of CPX.
- 9 April 2026
- Published by Brazilian Journal of Analytical Chemistry in Brazilian Journal of Analytical Chemistry
Laser-Induced Graphene Electrodes for the Voltammetric Determination of Ciprofloxacin in Pharmaceutical and Water Samples
This study reports a laser-induced graphene (LIG) electrode as a simple platform for the determination of ciprofloxacin (CPX). LIG was fabricated by laser scribing a Kapton® polyimide tape affixed to a ceramic substrate. Under optimized conditions, phosphate buffer as supporting electrolyte (0.10 mol L⁻¹, pH 7.0), and differential pulse voltammetry (pulse amplitude 60 mV, scan rate 30 mV s⁻¹), the method delivered a linear response from 8.3 to 166.7 μmol L⁻¹, with limits of detection and quantification of 2.5 and 8.3 μmol L⁻¹, respectively. The procedure was successfully applied to a pharmaceutical formulation and river water, yielding recoveries of 92.93–110% with good precision, thereby demonstrating the robustness of the method. The proposed LIG sensor is a cost-effective and sustainable alternative for environmental and quality control monitoring of CPX.
- Open Access
- 22 October 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (10)
Screen‐Printed Electrochemical Immunosensor Modified with Gold Nanoparticles for the Detection of Prostate Cancer Biomarker Human Kallikrein 2
Initially, a printed electrode was fabricated on a polyethylene terephthalate (PET) substrate using an ink based on graphite, carbon black, and nail polish. The working electrode was then modified with gold nanoparticles, followed by the sequential immobilization of antibodies specific to KLK2, bovine serum albumin (BSA), and KLK2 antigen as the target molecule. Several parameters were optimized to achieve the best performance of the immunosensor: antibody incubation time (40 min), BSA incubation time and concentration (30 min, 1.50 mg mL −1 ), antigen incubation time (60 min), supporting electrolyte pH (7.50), and supporting electrolyte concentration (0.01 mol L −1 ). After each modification step, the sensor was thoroughly washed with a 0.10 mol L −1 phosphate buffer (pH 7.00) and dried using a nitrogen stream. Reproducibility and interference studies demonstrated that the sensor exhibited good reproducibility and specificity for KLK2 detection. Subsequently, the sensor was applied to determine KLK2 in synthetic serum samples, achieving excellent recovery values ranging from 95.6% to 102%. These results suggest that the screen‐printed electrode (SPE)/AuNP/anti‐KLK2/BSA sensor holds promise for analyzing KLK2 in real serum samples.
- 22 October 2025
- Published by Wiley in Electroanalysis
- Vol. 37 (10)
Open AccessScreen‐Printed Electrochemical Immunosensor Modified with Gold Nanoparticles for the Detection of Prostate Cancer Biomarker Human Kallikrein 2
Initially, a printed electrode was fabricated on a polyethylene terephthalate (PET) substrate using an ink based on graphite, carbon black, and nail polish. The working electrode was then modified with gold nanoparticles, followed by the sequential immobilization of antibodies specific to KLK2, bovine serum albumin (BSA), and KLK2 antigen as the target molecule. Several parameters were optimized to achieve the best performance of the immunosensor: antibody incubation time (40 min), BSA incubation time and concentration (30 min, 1.50 mg mL −1 ), antigen incubation time (60 min), supporting electrolyte pH (7.50), and supporting electrolyte concentration (0.01 mol L −1 ). After each modification step, the sensor was thoroughly washed with a 0.10 mol L −1 phosphate buffer (pH 7.00) and dried using a nitrogen stream. Reproducibility and interference studies demonstrated that the sensor exhibited good reproducibility and specificity for KLK2 detection. Subsequently, the sensor was applied to determine KLK2 in synthetic serum samples, achieving excellent recovery values ranging from 95.6% to 102%. These results suggest that the screen‐printed electrode (SPE)/AuNP/anti‐KLK2/BSA sensor holds promise for analyzing KLK2 in real serum samples.
- Open Access
Influence of Surface Treatments on the Electrochemical Performance of Lab-Made 3D-Printed Electrodes
This study investigated the effect of surface treatments on the electrochemical performance of 3D-printed electrodes for versatile applications. The conductive filament was obtained from a mixture of polylactic acid (PLA) and carbon black (CB) at a 7:3 ratio (PLA/CB) dispersed in acetic acid and dichloroethane (3:1) medium. The treatments used were HNO3, NaOH, DMF (immersion for 30, 30, and 15 min, respectively), and electrochemical activation (amperometry 150 s, 1.8 V). In general, the treatments allow greater exposure of the conductive material and active sites present on the sensor surface. This was confirmed using cyclic voltammetry and electrochemical impedance spectroscopy. The analyses were conducted with a 0.10 M KCl solution containing the redox pair ferricyanide/ferrocyanide 5.00 mmol L−1. Based on the results obtained, the electroactive area, kinetic constant and resistance to electron transfer were determined for each treatment. The treatment in basic medium stood out as the treatment that was most appropriate for the device used in this work. The device was also tested for its potential in the analysis of acetaminophen, demonstrating satisfactory results permitting the application of 3D-SBasic in the analysis of acetaminophen.
Open AccessInfluence of Surface Treatments on the Electrochemical Performance of Lab-Made 3D-Printed Electrodes
This study investigated the effect of surface treatments on the electrochemical performance of 3D-printed electrodes for versatile applications. The conductive filament was obtained from a mixture of polylactic acid (PLA) and carbon black (CB) at a 7:3 ratio (PLA/CB) dispersed in acetic acid and dichloroethane (3:1) medium. The treatments used were HNO3, NaOH, DMF (immersion for 30, 30, and 15 min, respectively), and electrochemical activation (amperometry 150 s, 1.8 V). In general, the treatments allow greater exposure of the conductive material and active sites present on the sensor surface. This was confirmed using cyclic voltammetry and electrochemical impedance spectroscopy. The analyses were conducted with a 0.10 M KCl solution containing the redox pair ferricyanide/ferrocyanide 5.00 mmol L−1. Based on the results obtained, the electroactive area, kinetic constant and resistance to electron transfer were determined for each treatment. The treatment in basic medium stood out as the treatment that was most appropriate for the device used in this work. The device was also tested for its potential in the analysis of acetaminophen, demonstrating satisfactory results permitting the application of 3D-SBasic in the analysis of acetaminophen.
- Open Access
Development of Novel Conductive Inks for Screen-Printed Electrochemical Sensors: Enhancing Rapid and Sensitive Drug Detection
The development of screen-printed electrochemical sensors represents a rapidly expanding research field with great potential for applications in the rapid and sensitive determination of drugs in complex matrices. This work presents a review of the state-of-the-art examples of this technology, focusing on its application in real matrices such as water, pharmaceutical formulations, and biological fluids. We discuss the main materials used in developing conductive inks, highlighting their properties and influence on sensor performance. The characterization of materials and sensors is crucial to ensure the reproducibility and reliability of results. Additionally, we address the challenges associated with the application of these sensors in complex matrices, such as interferences from other components and the need for sample pretreatment. Finally, we present future perspectives for developing screen-printed electrochemical sensors, with an emphasis on new technologies and materials that can improve the sensitivity, selectivity, and stability of these devices.
Open AccessDevelopment of Novel Conductive Inks for Screen-Printed Electrochemical Sensors: Enhancing Rapid and Sensitive Drug Detection
The development of screen-printed electrochemical sensors represents a rapidly expanding research field with great potential for applications in the rapid and sensitive determination of drugs in complex matrices. This work presents a review of the state-of-the-art examples of this technology, focusing on its application in real matrices such as water, pharmaceutical formulations, and biological fluids. We discuss the main materials used in developing conductive inks, highlighting their properties and influence on sensor performance. The characterization of materials and sensors is crucial to ensure the reproducibility and reliability of results. Additionally, we address the challenges associated with the application of these sensors in complex matrices, such as interferences from other components and the need for sample pretreatment. Finally, we present future perspectives for developing screen-printed electrochemical sensors, with an emphasis on new technologies and materials that can improve the sensitivity, selectivity, and stability of these devices.
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 17 (2) , 227-241
Sensores Eletroquímicos para Detecção de Doenças por Meio de Análise Respiratória de Compostos Orgânicos Voláteis (COVs): uma Revisão Abrangente
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 17 (2) , 227-241
Sensores Eletroquímicos para Detecção de Doenças por Meio de Análise Respiratória de Compostos Orgânicos Voláteis (COVs): uma Revisão Abrangente
- Open Access
3D-Printed Electrochemical Sensors: A Comprehensive Review of Clinical Analysis Applications
Three-dimensional printing technology has emerged as a versatile and cost-effective alternative for the fabrication of electrochemical sensors. To enhance sensor sensitivity and biocompatibility, a diverse range of biocompatible and conductive materials can be employed in these devices. This allows these sensors to be modified to detect a wide range of analytes in various fields. 3D-printed electrochemical sensors have the potential to play a pivotal role in personalized medicine by enabling the real-time monitoring of metabolite and biomarker levels. These data can be used to personalize treatment strategies and optimize patient outcomes. The portability and low-cost nature of 3D-printed electrochemical sensors make them suitable for point-of-care (POC) diagnostics. These tests enable rapid and decentralized analyses, aiding in diagnosis and treatment decisions in resource-limited settings. Among the techniques widely reported in the literature for 3D printing, the fused deposition modeling (FDM) technique is the most commonly used for the development of electrochemical devices due to the easy accessibility of equipment and materials. Focusing on the FDM technique, this review explores the critical factors influencing the fabrication of electrochemical sensors and discusses potential applications in clinical analysis, while acknowledging the challenges that need to be overcome for its effective adoption.
Open Access3D-Printed Electrochemical Sensors: A Comprehensive Review of Clinical Analysis Applications
Three-dimensional printing technology has emerged as a versatile and cost-effective alternative for the fabrication of electrochemical sensors. To enhance sensor sensitivity and biocompatibility, a diverse range of biocompatible and conductive materials can be employed in these devices. This allows these sensors to be modified to detect a wide range of analytes in various fields. 3D-printed electrochemical sensors have the potential to play a pivotal role in personalized medicine by enabling the real-time monitoring of metabolite and biomarker levels. These data can be used to personalize treatment strategies and optimize patient outcomes. The portability and low-cost nature of 3D-printed electrochemical sensors make them suitable for point-of-care (POC) diagnostics. These tests enable rapid and decentralized analyses, aiding in diagnosis and treatment decisions in resource-limited settings. Among the techniques widely reported in the literature for 3D printing, the fused deposition modeling (FDM) technique is the most commonly used for the development of electrochemical devices due to the easy accessibility of equipment and materials. Focusing on the FDM technique, this review explores the critical factors influencing the fabrication of electrochemical sensors and discusses potential applications in clinical analysis, while acknowledging the challenges that need to be overcome for its effective adoption.
- Open Access
Electrochemical Determination of Catechol Using a Disposable Printed Electrode with Conductive Ink Based on Graphite and Carbon Black
Catechol (CT) is a phenolic compound widely used in various industrial sectors, but it is toxic; thus, there is a need for methods that aim to identify and quantify the existence of residues of this material in the environment. In this study a disposable printed electrochemical sensor was developed as an effective alternative for determining CT in water samples. The electrode, called SPEC, was manufactured using the screen-printing method using polyethylene terephthalate (PET) as a support, in which a conductive ink based on carbonaceous materials was used to print the working and auxiliary electrodes and a silver/silver chloride of ink on the reference electrode. The optimal ratio for the conductive ink was 6.25% carbon black, 35.42% graphite, and 58.33% nail polish. The ink obtained was characterized by scanning electron microscopy (SEM). The assessment of the effect of pH on the redox process showed Nernstian behavior (0.057 V pH−1), indicating that the process involves the same number of protons and electrons. Under optimized conditions, with 0.2 mol L−1 acetate buffer at pH 5.0, and by square wave voltammetry, the sensor presented sensitivity values of 0.31 μA L μmol−1, a detection limit of 5.96 μmol L−1, and a quantification limit of 19.87 μmol L−1. The sensor was applied to determine CT in tap water samples, and the results showed recoveries between 97.95 and 100.17%.
Open AccessElectrochemical Determination of Catechol Using a Disposable Printed Electrode with Conductive Ink Based on Graphite and Carbon Black
Catechol (CT) is a phenolic compound widely used in various industrial sectors, but it is toxic; thus, there is a need for methods that aim to identify and quantify the existence of residues of this material in the environment. In this study a disposable printed electrochemical sensor was developed as an effective alternative for determining CT in water samples. The electrode, called SPEC, was manufactured using the screen-printing method using polyethylene terephthalate (PET) as a support, in which a conductive ink based on carbonaceous materials was used to print the working and auxiliary electrodes and a silver/silver chloride of ink on the reference electrode. The optimal ratio for the conductive ink was 6.25% carbon black, 35.42% graphite, and 58.33% nail polish. The ink obtained was characterized by scanning electron microscopy (SEM). The assessment of the effect of pH on the redox process showed Nernstian behavior (0.057 V pH−1), indicating that the process involves the same number of protons and electrons. Under optimized conditions, with 0.2 mol L−1 acetate buffer at pH 5.0, and by square wave voltammetry, the sensor presented sensitivity values of 0.31 μA L μmol−1, a detection limit of 5.96 μmol L−1, and a quantification limit of 19.87 μmol L−1. The sensor was applied to determine CT in tap water samples, and the results showed recoveries between 97.95 and 100.17%.
- 27 May 2024
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (3) , 1173-1185
Development of a screen-printed electrochemical immunosensor modified with gold nanoparticles for prostate-specific antigen (PSA) detection
- 27 May 2024
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 29 (3) , 1173-1185
Development of a screen-printed electrochemical immunosensor modified with gold nanoparticles for prostate-specific antigen (PSA) detection
- Open Access
Development and Characterization of Conductive Ink Composed of Graphite and Carbon Black for Application in Printed Electrodes
This work developed a conductive ink composed of carbonaceous material for printing electrochemical sensors. The optimized ink comprises graphite, carbon black, and nail polish, respectively (35.3:11.7:53%), as well as acetone as a solvent. The proportion was optimized with consideration of the binder’s solubilization, the ink’s suitability for the screen-printing process, and lower electrical resistance. The materials used, and the resulting ink, were analyzed by way of Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), Raman spectroscopy, electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The charge transfer resistance (Rct) obtained was 0.348 kΩ. The conductive ink was used to print an electrode on a PET substrate, and a flexible and disposable electrode was obtained. The electroactive area obtained was 13.7 cm2, which was calculated by the Randles-Sevcik equation. The applicability of the device was demonstrated with a redox probe, providing a sensitivity of 0.02 µ A L mmol−1. The conductive ink has adequate homogeneity for producing electrodes using the screen-printing technique, with a low estimated production cost of $ 0.09 mL−1.
Open AccessDevelopment and Characterization of Conductive Ink Composed of Graphite and Carbon Black for Application in Printed Electrodes
This work developed a conductive ink composed of carbonaceous material for printing electrochemical sensors. The optimized ink comprises graphite, carbon black, and nail polish, respectively (35.3:11.7:53%), as well as acetone as a solvent. The proportion was optimized with consideration of the binder’s solubilization, the ink’s suitability for the screen-printing process, and lower electrical resistance. The materials used, and the resulting ink, were analyzed by way of Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), Raman spectroscopy, electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The charge transfer resistance (Rct) obtained was 0.348 kΩ. The conductive ink was used to print an electrode on a PET substrate, and a flexible and disposable electrode was obtained. The electroactive area obtained was 13.7 cm2, which was calculated by the Randles-Sevcik equation. The applicability of the device was demonstrated with a redox probe, providing a sensitivity of 0.02 µ A L mmol−1. The conductive ink has adequate homogeneity for producing electrodes using the screen-printing technique, with a low estimated production cost of $ 0.09 mL−1.
- 1 January 2022
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 14 (3) , 508-516
Carbon Nanostructures from Tailings: Synthesis, Characterization and Application in Dye Adsorption
- 1 January 2022
- Published by Sociedade Brasileira de Quimica (SBQ) in Revista Virtual de Química
- Vol. 14 (3) , 508-516
Carbon Nanostructures from Tailings: Synthesis, Characterization and Application in Dye Adsorption