- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-6
Commissioning of the 36 T Series-Connected Hybrid Magnet at the NHMFL
The National High Magnetic Field Laboratory (NHMFL) has commissioned a 36.1 T resistive/superconducting hybrid magnet with homogeneity and stability of 1 ppm over a 10 mm diameter spherical volume to be used for solid state NMR. Most NMR magnets use single strands of superconducting wire carrying a few hundred amps and persistent joints and switches. This mag-net uses a 20 kA superconducting cable in a steel conduit for the outer part of the magnet and copper-alloy sheet metal for the in-ner part of the magnet. While >15 hybrid magnets have been built worldwide, they typi-cally have a field uniformity of $\sim$250 ppm/cm DSV and stability might be no better than 50 ppm. To attain 1 ppm uniformity, current density grading was employed in the resistive coils to can-cel the z2 term. In addition, coils were shifted after the first map to reduce the z1 term. Ferroshims and resistive shims were in-stalled in the bore to attain <1 ppm over 10 mm. The large in-ductance of the superconducting coil reduced the ripple 6-fold compared with all-resistive magnets and essentially eliminated the 60Hz ripple and its harmonics. An NMR lock reduced the low-frequency drift to attain $\sim$0.1 ppm stability.
- 11 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-6
Open AccessCommissioning of the 36 T Series-Connected Hybrid Magnet at the NHMFL
The National High Magnetic Field Laboratory (NHMFL) has commissioned a 36.1 T resistive/superconducting hybrid magnet with homogeneity and stability of 1 ppm over a 10 mm diameter spherical volume to be used for solid state NMR. Most NMR magnets use single strands of superconducting wire carrying a few hundred amps and persistent joints and switches. This mag-net uses a 20 kA superconducting cable in a steel conduit for the outer part of the magnet and copper-alloy sheet metal for the in-ner part of the magnet. While >15 hybrid magnets have been built worldwide, they typi-cally have a field uniformity of $\sim$250 ppm/cm DSV and stability might be no better than 50 ppm. To attain 1 ppm uniformity, current density grading was employed in the resistive coils to can-cel the z2 term. In addition, coils were shifted after the first map to reduce the z1 term. Ferroshims and resistive shims were in-stalled in the bore to attain <1 ppm over 10 mm. The large in-ductance of the superconducting coil reduced the ripple 6-fold compared with all-resistive magnets and essentially eliminated the 60Hz ripple and its harmonics. An NMR lock reduced the low-frequency drift to attain $\sim$0.1 ppm stability.