Yulong Miao
Research Subjects
Yulong Miao has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Fuping Zeng
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Ju Tang
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications - Qiang Yao
Electric Power Research Institute of State Grid Chongqing Electric Power Company
2 shared publications - Lei Zhicheng
Jiangsu Frontier Electric Technology Co., LTD
1 shared publication - Siying Wu
Simon Fraser University Vancouver Canada
1 shared publication - Xu Yang
School of Electrical Engineering, Wuhan University, Wuhan 430072, China
1 shared publication
Latest Publications
- 25 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1470-1477
Triangle Fault Diagnosis Method for SF6 Gas-Insulated Equipment
The use of SF6 gas decomposition components for the fault diagnosis of gas insulated equipment (GIE) has received widespread attention and been extensively adopted by the power industry. However, the present focus is mainly the use of a component type or absolute content for generating qualitative judgments on the existence of a fault, and the practical diagnosis method for field diagnosis is extremely lacking. In this paper, ten-year fault data were collected and analyzed. Decomposition components were extracted and combined based on the decomposition characteristics of SF6, and enhancement factors were given to three component characteristic quantities using fuzzy C-means clustering algorithm (FCM). The component characteristic quantities that characterized the high-energy discharge fault, partial discharge, and partial over-thermal fault of the device were extracted: % $\rm (SOF_{2}+SO_2)$ , % $\rm (9SO_{2}F_2)$ , and % $\rm (5CO_2)$ . With adoption of these characteristic quantities as the coordinate axes of the triangle coordinate system, a triangle fault diagnosis method for field diagnosis of SF6 GIE was constructed. The diagnosis method was validated by a large number of experimental data and field failure data, and 128 of the 150 experimental samples were correctly recognized. Moreover, the test conditions did not considerably affect the diagnostic results of the method. This technique can provide a simple and effective field diagnostics technology for the power industry.- 25 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1470-1477
Triangle Fault Diagnosis Method for SF6 Gas-Insulated Equipment
The use of SF6 gas decomposition components for the fault diagnosis of gas insulated equipment (GIE) has received widespread attention and been extensively adopted by the power industry. However, the present focus is mainly the use of a component type or absolute content for generating qualitative judgments on the existence of a fault, and the practical diagnosis method for field diagnosis is extremely lacking. In this paper, ten-year fault data were collected and analyzed. Decomposition components were extracted and combined based on the decomposition characteristics of SF6, and enhancement factors were given to three component characteristic quantities using fuzzy C-means clustering algorithm (FCM). The component characteristic quantities that characterized the high-energy discharge fault, partial discharge, and partial over-thermal fault of the device were extracted: % $\rm (SOF_{2}+SO_2)$ , % $\rm (9SO_{2}F_2)$ , and % $\rm (5CO_2)$ . With adoption of these characteristic quantities as the coordinate axes of the triangle coordinate system, a triangle fault diagnosis method for field diagnosis of SF6 GIE was constructed. The diagnosis method was validated by a large number of experimental data and field failure data, and 128 of the 150 experimental samples were correctly recognized. Moreover, the test conditions did not considerably affect the diagnostic results of the method. This technique can provide a simple and effective field diagnostics technology for the power industry.- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1383-1392
Evaluating DC Partial Discharge With SF6 Decomposition Characteristics
This study mainly aims to obtain the decomposition characteristics of SF6 under various degrees of negative partial discharge (PD) and establish a method for evaluating internal PD fault for gas-insulated equipment (GIE). Thus, metal protrusion, a frequent insulation defect in DC GIE, was used in the study of PD characteristics from the initial discharge to the near breakdown process. Then, seven parameters for characterizing the development stage of PD were extracted, and the fuzzy C-means clustering algorithm was used for the categorization of PD into three degrees, namely, slight, medium, and severe. We performed SF6 decomposition experiments on the PD degrees to obtain the decomposition characteristics. Results show that the SF6 decomposition characteristics (formation and content variation of five characteristic components, namely, CF4, CO2, SO2F2, SOF2, and SO2) are closely related to PD status. Fuzzy comprehensive evaluation theory was used for the establishment of a PD fault status assessment model, which was based on SF6 decomposition characteristics. Then evaluate the collected samples and the accuracy of the evaluation method is up to 87.5%. This paper lays the foundation for the future comprehensive assessment and fault diagnosis of insulation status of DC GIE on the basis of SF6 decomposition characteristics.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 34 (4) , 1383-1392
Evaluating DC Partial Discharge With SF6 Decomposition Characteristics
This study mainly aims to obtain the decomposition characteristics of SF6 under various degrees of negative partial discharge (PD) and establish a method for evaluating internal PD fault for gas-insulated equipment (GIE). Thus, metal protrusion, a frequent insulation defect in DC GIE, was used in the study of PD characteristics from the initial discharge to the near breakdown process. Then, seven parameters for characterizing the development stage of PD were extracted, and the fuzzy C-means clustering algorithm was used for the categorization of PD into three degrees, namely, slight, medium, and severe. We performed SF6 decomposition experiments on the PD degrees to obtain the decomposition characteristics. Results show that the SF6 decomposition characteristics (formation and content variation of five characteristic components, namely, CF4, CO2, SO2F2, SOF2, and SO2) are closely related to PD status. Fuzzy comprehensive evaluation theory was used for the establishment of a PD fault status assessment model, which was based on SF6 decomposition characteristics. Then evaluate the collected samples and the accuracy of the evaluation method is up to 87.5%. This paper lays the foundation for the future comprehensive assessment and fault diagnosis of insulation status of DC GIE on the basis of SF6 decomposition characteristics.