Massimo Marzinotto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Massimo Marzinotto has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Mazzetti
Electrical Engineering Department, Sapienza University of Roma, Via Eudossiana 18, 00184 Roma, Italy
5 shared publications - Giovanni Mazzanti
Department of Electrical, Electronic and Information Engineering, University of Bologna, Bologna, Italy
4 shared publications - F. Fiamingo
Department of Safety Technology (DTS), Research, Certification and Verification Sector, Istituto Nazionale per l’Assicurazione contro gli Infortuni sul Lavoro (INAIL), Italy
3 shared publications - Mario Nervi
Dipartimento di Ingegneria Elettrica, Università di Genova, Genova, Italy
3 shared publications - Paolo Molfino
Electrical, Electronics and Telecommunication Engineering and Naval Architecture Department, University of Genoa, Via All’Opera Pia 11, 16145 Genoa, Italy
3 shared publications - Daniele Mestriner
Department of Naval, Electronic, Electrical and Telecommunication Engineering, University of Genoa, Genoa, Italy
2 shared publications
Latest Publications
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (4) , 1375
Corrections to “Ground-Return Parameters of Submarine Cables Buried in the Seabed”
In [1], (5b) has a typo; the correct formula is as follows: \begin{equation*} \Delta _{6}^{\mathrm{QT}} = \int \nolimits _{0}^{\infty } \frac{{\mathrm{e}}^{-2 \alpha _{2} h_{ij}}}{\alpha _{1}+\alpha _{2}}\frac{1}{\alpha _{2}^{2}} \cos \left(q_{ij}\lambda \right) \,{\mathrm{{d}}}\lambda \;. \tag{1} \end{equation*} In (34), the term $G_{\mathrm{b}} (\lambda)$ is missing of the denominator; the correct formula is as follows: \begin{equation*} \begin{aligned} G_{\mathrm{b}} \left(\lambda \right) = &\\ =& \frac{2 \mu _{1} \mu _{2} \alpha _{2} {\mathrm{e}}^{-\alpha _{2} \left(h_{1}+h_{2}-2h_{\mathrm{s}} \right) }}{ \left(A_{10}A_{21}+\Delta _{10}\Delta _{21}{\mathrm{e}}^{-2\alpha _{1}h_{\mathrm{s}}} \right) \left(s_{10}s_{21}-d_{10}d_{21}{\mathrm{e}}^{-2\alpha _{1} h_{\mathrm{s}}} \right) } \cdot \\ & \!\!\! \left\lbrace \phantom{\int }{\kern-10.0pt} \left(\gamma _{2}^{2} \!-\ \gamma _{1}^{2} \right) \left( s_{10} A_{10} \!-\! d_{10}\Delta _{10} {\mathrm{e}}^{-4 \alpha _{1} h_{\mathrm{s}}} \right) \!-\! 2 \mu _{0} \mu _{1} {\mathrm{e}}^{-2 \alpha _{1} h_{\mathrm{s}}} \right. \cdot \\ & \!\!\! \left. \left[ \alpha _{0}^{2} \gamma _{1}^{2} \left(\gamma _{2}^{2} - \gamma _{1}^{2} \right) + \alpha _{1}^{2} \gamma _{0}^{2} \left(\gamma _{2}^{2} + \gamma _{1}^{2} \right) - 2 \alpha _{1}^{2} \gamma _{1}^{2} \gamma _{2}^{2} \right] \phantom{\int }{\kern-10.0pt} \right\rbrace \, \end{aligned} \tag{2} \end{equation*}- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 67 (4) , 1375
Corrections to “Ground-Return Parameters of Submarine Cables Buried in the Seabed”
In [1], (5b) has a typo; the correct formula is as follows: \begin{equation*} \Delta _{6}^{\mathrm{QT}} = \int \nolimits _{0}^{\infty } \frac{{\mathrm{e}}^{-2 \alpha _{2} h_{ij}}}{\alpha _{1}+\alpha _{2}}\frac{1}{\alpha _{2}^{2}} \cos \left(q_{ij}\lambda \right) \,{\mathrm{{d}}}\lambda \;. \tag{1} \end{equation*} In (34), the term $G_{\mathrm{b}} (\lambda)$ is missing of the denominator; the correct formula is as follows: \begin{equation*} \begin{aligned} G_{\mathrm{b}} \left(\lambda \right) = &\\ =& \frac{2 \mu _{1} \mu _{2} \alpha _{2} {\mathrm{e}}^{-\alpha _{2} \left(h_{1}+h_{2}-2h_{\mathrm{s}} \right) }}{ \left(A_{10}A_{21}+\Delta _{10}\Delta _{21}{\mathrm{e}}^{-2\alpha _{1}h_{\mathrm{s}}} \right) \left(s_{10}s_{21}-d_{10}d_{21}{\mathrm{e}}^{-2\alpha _{1} h_{\mathrm{s}}} \right) } \cdot \\ & \!\!\! \left\lbrace \phantom{\int }{\kern-10.0pt} \left(\gamma _{2}^{2} \!-\ \gamma _{1}^{2} \right) \left( s_{10} A_{10} \!-\! d_{10}\Delta _{10} {\mathrm{e}}^{-4 \alpha _{1} h_{\mathrm{s}}} \right) \!-\! 2 \mu _{0} \mu _{1} {\mathrm{e}}^{-2 \alpha _{1} h_{\mathrm{s}}} \right. \cdot \\ & \!\!\! \left. \left[ \alpha _{0}^{2} \gamma _{1}^{2} \left(\gamma _{2}^{2} - \gamma _{1}^{2} \right) + \alpha _{1}^{2} \gamma _{0}^{2} \left(\gamma _{2}^{2} + \gamma _{1}^{2} \right) - 2 \alpha _{1}^{2} \gamma _{1}^{2} \gamma _{2}^{2} \right] \phantom{\int }{\kern-10.0pt} \right\rbrace \, \end{aligned} \tag{2} \end{equation*}- Open Access
Life Estimation of HVDC Cables Subjected to Fast and Slow Polarity Reversals
This paper aims at estimating the life of extruded HVDC cable insulation subjected to fast and slow voltage polarity reversals (VPRs). An ad hoc MATLAB code is used for the transient electric field simulation in the cable insulation thickness by solving numerically Gauss, ohm, and current continuity equations beside a macroscopic conductivity equation. A transient temperature is also considered during slow VPR transients. The results show a significant localized reduction in the life of the inner insulation, making the life distribution non-monotonous inside the insulation thickness. The results show that fast VPRs are the most stressing transients in this study. The longer the duration of the zero-voltage period in slow VPR, the less stressed the insulation, hence, the longer the local life in the inner insulation of the cable. The latter is justified by the charge relaxation during slow VPRs.
Open AccessLife Estimation of HVDC Cables Subjected to Fast and Slow Polarity Reversals
This paper aims at estimating the life of extruded HVDC cable insulation subjected to fast and slow voltage polarity reversals (VPRs). An ad hoc MATLAB code is used for the transient electric field simulation in the cable insulation thickness by solving numerically Gauss, ohm, and current continuity equations beside a macroscopic conductivity equation. A transient temperature is also considered during slow VPR transients. The results show a significant localized reduction in the life of the inner insulation, making the life distribution non-monotonous inside the insulation thickness. The results show that fast VPRs are the most stressing transients in this study. The longer the duration of the zero-voltage period in slow VPR, the less stressed the insulation, hence, the longer the local life in the inner insulation of the cable. The latter is justified by the charge relaxation during slow VPRs.
- Open Access
- 29 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12788
On the Chemical Composition and Hygroscopicity of Aerosols Deposited on the Insulators of Italian Power Lines
The reliability of the national power grid is a key issue in modern society. Atmospheric aerosols are the main cause of the reduction in the performance of insulators and the increase in the possibility of flashovers, resulting in power line failures. Under high ambient humidity, the water-soluble compounds of atmospheric aerosols collected on the insulators’ surface can dissociate in ions and form a conductive layer, which may lead to flashover events. With a view to investigating the processes that drive these phenomena, the chemical composition of aerosol deposits on insulators in Italy was determined by ion chromatography analysis and thermos-optical and X-ray techniques. In addition, a synthetic aerosol with the same analyzed chemical composition was generated in a laboratory and deposited on PTFE filters and glass specimens allowing us to determine the deliquescence and crystallization relative humidity and the conductive effect in an aerosol exposure chamber. The results evidenced the presence of a hazardous inorganic ion layer, which generates a sharp phase transition of the aerosol deposit as a function of the ambient relative humidity; this layer poses a dangerous threat to the reliability of the power grid, increasing the probability of flashover events where the conductive layer facilitates the flow of electrical current across the insulator surface, potentially causing power outages or damage to the power lines.
- 29 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12788
Open AccessOn the Chemical Composition and Hygroscopicity of Aerosols Deposited on the Insulators of Italian Power Lines
The reliability of the national power grid is a key issue in modern society. Atmospheric aerosols are the main cause of the reduction in the performance of insulators and the increase in the possibility of flashovers, resulting in power line failures. Under high ambient humidity, the water-soluble compounds of atmospheric aerosols collected on the insulators’ surface can dissociate in ions and form a conductive layer, which may lead to flashover events. With a view to investigating the processes that drive these phenomena, the chemical composition of aerosol deposits on insulators in Italy was determined by ion chromatography analysis and thermos-optical and X-ray techniques. In addition, a synthetic aerosol with the same analyzed chemical composition was generated in a laboratory and deposited on PTFE filters and glass specimens allowing us to determine the deliquescence and crystallization relative humidity and the conductive effect in an aerosol exposure chamber. The results evidenced the presence of a hazardous inorganic ion layer, which generates a sharp phase transition of the aerosol deposit as a function of the ambient relative humidity; this layer poses a dangerous threat to the reliability of the power grid, increasing the probability of flashover events where the conductive layer facilitates the flow of electrical current across the insulator surface, potentially causing power outages or damage to the power lines.
- Open Access
The Mitigation of Interference on Underground Power Lines Caused by the HVDC Electrode
High Voltage Direct Current power links are usually designed to adopt, on a continuous basis or during emergency operations, two grounding plants using the soil or seawater as a link–current return path. Such DCs flowing into the ground can cause problems, of which one of the most important is the increased risk of the corrosion of metallic structures in the area. Normally, the simplest mitigation technique is to keep an adequate distance between the main grounding plants and any metallic structure that can be corroded. Normally, such distances are not less than 5 km. However, there are situations where this approach cannot be applied, for example due to geographical constraints. In this paper, we describe and analyze the behavior of a mitigation technique that can be adopted when the HV pole cable is laid closer than the recommended distance to the main ground electrode. This paper is focused on the minimization of deleterious effects on the cable’s metallic sheath and its earthing points, distributed along it by means of sheath segmentation. The suggested approach appears well-suited to substantially diminishing the current flowing through the sheath of an HVDC power cable. In the segmented scenario, the sheath’s power dissipation is less than one-hundredth of that in the typical continuous configuration.
Open AccessThe Mitigation of Interference on Underground Power Lines Caused by the HVDC Electrode
High Voltage Direct Current power links are usually designed to adopt, on a continuous basis or during emergency operations, two grounding plants using the soil or seawater as a link–current return path. Such DCs flowing into the ground can cause problems, of which one of the most important is the increased risk of the corrosion of metallic structures in the area. Normally, the simplest mitigation technique is to keep an adequate distance between the main grounding plants and any metallic structure that can be corroded. Normally, such distances are not less than 5 km. However, there are situations where this approach cannot be applied, for example due to geographical constraints. In this paper, we describe and analyze the behavior of a mitigation technique that can be adopted when the HV pole cable is laid closer than the recommended distance to the main ground electrode. This paper is focused on the minimization of deleterious effects on the cable’s metallic sheath and its earthing points, distributed along it by means of sheath segmentation. The suggested approach appears well-suited to substantially diminishing the current flowing through the sheath of an HVDC power cable. In the segmented scenario, the sheath’s power dissipation is less than one-hundredth of that in the typical continuous configuration.
- Open Access
An Overview on Reversible Sea Return Electrodes for HVDC Links
HVDC electrodes are usually implemented in HVDC links to avoid the installation of a metallic return. Submarine cables, especially those dealing with lengths of thousands of kilometers, are expensive, and high costs of laying are normally expected. Due to the high number of reversible HVDC links, the marine electrodes must be able to withstand both anodic and cathodic operations, which leads to careful considerations in terms of the material to be used. This paper shows the state of the art of the currently installed reversible sea return electrodes, focusing on the type of installation (sea, shore or pond electrodes) and on the material used, from the first plant installed in 1954 up to the more recent ones established during the XXI century. All reported data derive from publicly available sources. Moreover, since nowadays environmental issues are among the most important topics, for each material and for each type of installation, a guideline on the possible interferences caused by marine electrodes with the surrounding environment is proposed.
Open AccessAn Overview on Reversible Sea Return Electrodes for HVDC Links
HVDC electrodes are usually implemented in HVDC links to avoid the installation of a metallic return. Submarine cables, especially those dealing with lengths of thousands of kilometers, are expensive, and high costs of laying are normally expected. Due to the high number of reversible HVDC links, the marine electrodes must be able to withstand both anodic and cathodic operations, which leads to careful considerations in terms of the material to be used. This paper shows the state of the art of the currently installed reversible sea return electrodes, focusing on the type of installation (sea, shore or pond electrodes) and on the material used, from the first plant installed in 1954 up to the more recent ones established during the XXI century. All reported data derive from publicly available sources. Moreover, since nowadays environmental issues are among the most important topics, for each material and for each type of installation, a guideline on the possible interferences caused by marine electrodes with the surrounding environment is proposed.
- Open Access
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (2) , 574-584
Ground-Return Parameters of Submarine Cables Buried in the Seabed
The computation of sea/seabed-return distributed parameters of subsea cables is a relevant topic due to the growing importance of submarine connections. This article presents for the first time new formulas for the computation of self and mutual ground impedances and admittances for submarine cables buried in the seabed. The original theory developed by Sunde is applied to a three-media model with air, sea, and seabed. Referring to the practical installation practice of the Italian transmission system operator Terna S.p.A., we compare the prediction of the available models and assess the effect of the different approximations on the computation of the per unit length ground parameters. Finally, we define the limits of applicability of the available models that differ in accuracy and complexity.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (2) , 574-584
Open AccessGround-Return Parameters of Submarine Cables Buried in the Seabed
The computation of sea/seabed-return distributed parameters of subsea cables is a relevant topic due to the growing importance of submarine connections. This article presents for the first time new formulas for the computation of self and mutual ground impedances and admittances for submarine cables buried in the seabed. The original theory developed by Sunde is applied to a three-media model with air, sea, and seabed. Referring to the practical installation practice of the Italian transmission system operator Terna S.p.A., we compare the prediction of the available models and assess the effect of the different approximations on the computation of the per unit length ground parameters. Finally, we define the limits of applicability of the available models that differ in accuracy and complexity.
- 16 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (6) , 4603-4611
Comparison of the Quick Flashover Voltages for RTV Pre-Coated Insulators Sampled Over the Years From the Italian AC Transmission Grid
This paper widens the application of a testing protocol for overhead line insulators introduced by TERNA. Testing results relevant to three groups of Room Temperature Vulcanized pre-coated cap-and-pin insulators removed from High Voltage Alternate Current and Extra-High Voltage Alternate Current Italian lines after different years of service are reported and statistically processed; the third group is treated here for the first time and new results for the other two groups are included. Among the various tests prescribed in the protocol, focus is on the Quick Flashover test, with the aim to examine and compare the flashover voltages of all three groups as a function of service time. The dependence of flashover voltage on electric field is also analyzed and a model correlating flashover voltage with field and time is proposed for the first time. It is confirmed that the flashover voltages provided by the Quick Flashover test can be considered as a diagnostic property of Room Temperature Vulcanized insulators, as they drop with the ageing time and the electric field.
- 16 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (6) , 4603-4611
Comparison of the Quick Flashover Voltages for RTV Pre-Coated Insulators Sampled Over the Years From the Italian AC Transmission Grid
This paper widens the application of a testing protocol for overhead line insulators introduced by TERNA. Testing results relevant to three groups of Room Temperature Vulcanized pre-coated cap-and-pin insulators removed from High Voltage Alternate Current and Extra-High Voltage Alternate Current Italian lines after different years of service are reported and statistically processed; the third group is treated here for the first time and new results for the other two groups are included. Among the various tests prescribed in the protocol, focus is on the Quick Flashover test, with the aim to examine and compare the flashover voltages of all three groups as a function of service time. The dependence of flashover voltage on electric field is also analyzed and a model correlating flashover voltage with field and time is proposed for the first time. It is confirmed that the flashover voltages provided by the Quick Flashover test can be considered as a diagnostic property of Room Temperature Vulcanized insulators, as they drop with the ageing time and the electric field.
- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
On the materials for reversible HVDC sea electrodes: a comparison aimed at their correct selection
Over the last years the use of HVDC transmission has been constantly increasing worldwide. Furthermore, new converters based on IGBT (called VSC converters) are spreading. This fact leads to develop reversible sea electrodes, as the direction of the current may frequently change. In this paper, we would like to clarify the subject, especially examining in detail the materials that can be used to effectively manufacture deep-sea return electrodes that can be operated with minimal or no maintenance over their life.
- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
On the materials for reversible HVDC sea electrodes: a comparison aimed at their correct selection
Over the last years the use of HVDC transmission has been constantly increasing worldwide. Furthermore, new converters based on IGBT (called VSC converters) are spreading. This fact leads to develop reversible sea electrodes, as the direction of the current may frequently change. In this paper, we would like to clarify the subject, especially examining in detail the materials that can be used to effectively manufacture deep-sea return electrodes that can be operated with minimal or no maintenance over their life.
- Open Access
- 1 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (2) , 115-122
Comparing frequency‐dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages
Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequency‐dependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency‐dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.
- 1 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 13 (2) , 115-122
Open AccessComparing frequency‐dependent and distributed parameter with lumped losses power cable line models for cable insulation coordination against overvoltages
Simulations of transients are an obliged step for the insulation coordination of cable lines. Although a frequency‐dependent power cable line model better takes into account real conditions since resistive and inductive parameters vary with frequency, a distributed parameter with lumped losses power cable models can be useful to simplify and give higher flexibility to the insulation coordination study. In such a case, a dilemma rises up when a frequency shall be selected for the determination of the cable parameters. In this study, a comparative analysis between the two models has been performed considering a typical configuration layout, i.e. an overvoltage coming from an overhead line and stressing the cable line terminated on a transformer. The overvoltages stressing both cable insulation wall and cable thermoplastic jacket are evaluated using the same system configuration with both frequency‐dependent and distributed parameter with lumped losses power cable line models, in the latter case sweeping different frequency values for the determination of the cable parameters. A frequency range that minimise the differences between the overvoltage estimation using the two models is suggested.
- 30 July 2011
- Published by Elsevier in Electric Power Systems Research
- Vol. 85, 75-81
Quality of the supplied electric service: A tool to evaluate the need of protection against lightning surges
- 30 July 2011
- Published by Elsevier in Electric Power Systems Research
- Vol. 85, 75-81
Quality of the supplied electric service: A tool to evaluate the need of protection against lightning surges