Latest Publications

  • Study of Modified Flux-Coupling-Type SFCLs For Stability Improvement of a Multi-Machine Power System Based On Energy Function

    by Lei Chen, Ruizhe Hu, Xinyi Deng, Hongkun Chen, Yanhong Li, Tong Ding, Youjun Yin, Lei Wang, Huiwen He

    This paper investigates modified ux-coupling-type superconducting fault current limiters (SFCLs) for enhancing the transient stability of a multi-machine power system (MMPS). The clustering architecture of the MMPS with the modified SFCLs is presented, and the transient energy function (TEF) of the MMPS is established. Through clarifying the potential influence of the modified SFCLs, theoretical analysis signifies that the modified SFCLs can reduce the transient energy accumulation during the fault-feeding period, and increase the transient stability margin of the MMPS. Using MATLAB/Simulink, a benchmark IEEE 9-bus system with the SFCLs is modeled, and the simulation analysis of the generator rotor swing behaviors is carried out. Varying the resistive-inductive parameters and altering the positions of the SFCLs are considered, and the TEF method is applied to gain quantitative effects. The simulation findings in different scenarios testify the correctness of the theoretical analysis. The presence of the SFCLs can availably reduce the generator rotor oscillating and restrain the transient energy changing, and meanwhile, an extension of the critical clearance time is achieved for the MMPS.


  • Investigation of a Modified Flux-Coupling-Type SFCL for Low-Voltage Ride-Through Fulfillment of a Virtual Synchronous Generator

    by Lei Chen, Guocheng Li, Hongkun Chen, Meng Ding, Xuyang Zhang, Yanhong Li, Ying Xu, Li Ren, Yuejin Tang

    To solve the low-voltage ride-through (LVRT) issue of a virtual synchronous generator (VSG) under severe grid fault, our research group proposes to use a modified flux-coupling-type superconducting fault current limiter (SFCL). In this study, the configuration structure of the VSG with the SFCL at the point of common coupling (PCC) is designed. The fault analytical circuit of the VSG is presented, and the functions of the SFCL are stated from the aspects of current restraint, voltage compensation, and energy dissipation. Using MATLAB/Simulink, symmetrical and asymmetrical faults are both simulated to assess the transient behaviors of the VSG, and the SFCL parameters are changed to clarify the quantitative effects. From the comparison results, the SFCL parameters are properly determined to provide favorable performance. The SFCL can visibly decrease the fault current of each phase within the permissible level, and facilitate the VSG to have a preferable voltage profile. Furthermore, the SFCL can positively stabilize the VSG by enhancing the power delivery, mitigating the frequency fluctuation and consuming the excess energy. A satisfactory LVRT operation is gained, and the efficacy of the SFCL on reinforcing the VSG robustness is validated.


  • Study on Coordination of Resistive SFCLs and Hybrid-Type Circuit Breakers to Protect a HVDC System With LCC and VSC Stations

    by Lei Chen, Guocheng Li, Huiwen He, Hongkun Chen, Yanhong Li, Meng Ding, Xuyang Zhang, Ying Xu, Li Ren, Yuejin Tang

    Directing at the robustness increase of a high voltage direct current (HVDC) system with line commutated converter (LCC) and voltage source converter (VSC), this paper proposes to coordinate resistive superconducting fault current limiters (SFCLs) and hybrid-type DC circuit breakers (HDCBs) for dealing with the DC line fault. The theoretical modeling of the SFCLs is presented, and the DC fault current characteristics are analyzed. Considering that the fault interruption involves multi-stages, the coordination of the SFCL and the HDCB in the LCC/VSC station is elaborated. Using PSCAD/EMTDC, the simulation model of a 320 kV HVDC system is built. Changing the SFCL size and the HDCB operation delay is simulated, and the performance indexes such as the fault current level, breaking time and dissipated energy are compared. The proposed coordination is verified to be very effective in handling the fault. Especially for the VSC station, it enables to visibly limit the fault current rising, shorten the transient voltage duration, and facilitate a significant decrease in the dissipated energy of the HDCB. For the LCC station, the proposed coordination can serve as a competitive backup to ensure a timely fault breaking. Consequently, the DC line fault is removed more rapidly and reliably.