Ke Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ke Guo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Bao Xie
State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing People's Republic of China
1 shared publication- Bao Xie
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
1 shared publication - Gaofeng Hao
State Grid Henan Electric Power Research Institute
1 shared publication Lin Zhou
State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing People's Republic of China
1 shared publication- Lin Zhou
Chongqing University, 47913 Chongqing, Sichuan China
1 shared publication Mingxuan Mao
State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (7) , 1291-1301
Modelling and robust control of digitally controlled large‐scale PV plants
Large‐scale photovoltaic (PV) plants may be destabilised by the large grid impedance introduced by transformers and long transmission lines. When considering the digital control delay of grid‐connected inverters, the problem will become more serious. In this study, the equivalent impedance model of digitally controlled large‐scale PV plants is established, considering that the values of the parameters of the LCL filter follow Gaussian distributions. Then, the system stability can be analysed conveniently, and the stability analysis shows that the digital control delay will make the system robust to large grid impedance worse. To enhance the stability‐robustness of the system, an H ∞ robust controller is proposed in this study. By properly selecting the weighting functions, the desired tracking error performance and robustness are achieved on the basis of the mixed‐sensitivity optimisation control design. Compared with the traditional dual current loop control strategy, the H ∞ robust controller improves significantly the system stability‐robustness against large grid impedance. Finally, simulation and experimental tests are carried out in this study, and the results demonstrate the effectiveness of the proposed H ∞ robust controller.
- 1 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (7) , 1291-1301
Open AccessModelling and robust control of digitally controlled large‐scale PV plants
Large‐scale photovoltaic (PV) plants may be destabilised by the large grid impedance introduced by transformers and long transmission lines. When considering the digital control delay of grid‐connected inverters, the problem will become more serious. In this study, the equivalent impedance model of digitally controlled large‐scale PV plants is established, considering that the values of the parameters of the LCL filter follow Gaussian distributions. Then, the system stability can be analysed conveniently, and the stability analysis shows that the digital control delay will make the system robust to large grid impedance worse. To enhance the stability‐robustness of the system, an H ∞ robust controller is proposed in this study. By properly selecting the weighting functions, the desired tracking error performance and robustness are achieved on the basis of the mixed‐sensitivity optimisation control design. Compared with the traditional dual current loop control strategy, the H ∞ robust controller improves significantly the system stability‐robustness against large grid impedance. Finally, simulation and experimental tests are carried out in this study, and the results demonstrate the effectiveness of the proposed H ∞ robust controller.
- 5 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1453-1464
Analysis and Improved Design of Phase Compensated Proportional Resonant Controllers for Grid-Connected Inverters in Weak Grid
Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.
- 5 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1453-1464
Analysis and Improved Design of Phase Compensated Proportional Resonant Controllers for Grid-Connected Inverters in Weak Grid
Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.