Zhixiang Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhixiang Zou has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Zheng Wang
School of Electrical Engineering, Southeast University, Nanjing, China
21 shared publications - Marco Liserre
Kiel University
20 shared publications - Giampaolo Buticchi
Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, China
17 shared publications - Wu Chen
Southeast University
11 shared publications - Fujin Deng
Southeast University
8 shared publications - Jian Tang
School of Electrical Engineering, Southeast University, Nanjing, China
6 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21688-21703
Grid-Forming Control With Self-Sustained Inertia and Transient Stability Enhancement for Type-IV Wind Turbines
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21688-21703
Grid-Forming Control With Self-Sustained Inertia and Transient Stability Enhancement for Type-IV Wind Turbines
- Open Access
- 14 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5305
Fault Detection with Weak Electrical Signatures in Grid-Connected Distributed PV Systems Using Positive-to-Negative-Sequence Perturbation Responses
Inverter current control can significantly weaken power-frequency fault signatures in distribution networks with high photovoltaic (PV) penetration. This paper proposes an active fault detection method using positive-to-negative-sequence perturbation responses. A small-signal positive-sequence voltage is injected on the low-voltage side of the PV step-up transformer, and the target-frequency ratio of negative-sequence voltage to positive-sequence current (Knp = Vn/Ip) measured at the medium-voltage point of common coupling (PCC) quantifies the resulting cross-sequence coupling response. Sequence-domain analysis combined with nodal admittance reduction explains the off-diagonal coupling terms introduced by single-phase ground and series faults and extends the observation principle to intermittent arcing faults. Sliding-window phasor estimation, a calibrated and locked normal-operation baseline, and consecutive confirmation form the online protection criterion. Co-simulation demonstrates a 13.133–22.638 dB index change across 650–850 Hz and a 37.43–43.35 dB separation between healthy and faulted states across the tested operating and grid strength variations. A 32-point fault resistance sweep characterizes the baseline-crossing mechanism responsible for the intermediate magnitude–sensitivity gap near 3.68 kΩ and verifies detection recovery up to 24 kΩ under the nominal 3 dB threshold. RT-Box real-time tests confirm online trip generation within 20 ms for all three fault types. Furthermore, robustness evaluations verify reliable detection of the representative 10 Ω fault down to a 20 dB target-frequency SNR under a fixed 14.5 dB anti-noise threshold, while explicitly quantifying the selectivity and sensitivity trade-offs under non-fault switching, channel mismatch, and the reduced kilohm-range sensitivity caused by the elevated anti-noise threshold.
- 14 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5305
Open AccessFault Detection with Weak Electrical Signatures in Grid-Connected Distributed PV Systems Using Positive-to-Negative-Sequence Perturbation Responses
Inverter current control can significantly weaken power-frequency fault signatures in distribution networks with high photovoltaic (PV) penetration. This paper proposes an active fault detection method using positive-to-negative-sequence perturbation responses. A small-signal positive-sequence voltage is injected on the low-voltage side of the PV step-up transformer, and the target-frequency ratio of negative-sequence voltage to positive-sequence current (Knp = Vn/Ip) measured at the medium-voltage point of common coupling (PCC) quantifies the resulting cross-sequence coupling response. Sequence-domain analysis combined with nodal admittance reduction explains the off-diagonal coupling terms introduced by single-phase ground and series faults and extends the observation principle to intermittent arcing faults. Sliding-window phasor estimation, a calibrated and locked normal-operation baseline, and consecutive confirmation form the online protection criterion. Co-simulation demonstrates a 13.133–22.638 dB index change across 650–850 Hz and a 37.43–43.35 dB separation between healthy and faulted states across the tested operating and grid strength variations. A 32-point fault resistance sweep characterizes the baseline-crossing mechanism responsible for the intermediate magnitude–sensitivity gap near 3.68 kΩ and verifies detection recovery up to 24 kΩ under the nominal 3 dB threshold. RT-Box real-time tests confirm online trip generation within 20 ms for all three fault types. Furthermore, robustness evaluations verify reliable detection of the representative 10 Ω fault down to a 20 dB target-frequency SNR under a fixed 14.5 dB anti-noise threshold, while explicitly quantifying the selectivity and sensitivity trade-offs under non-fault switching, channel mismatch, and the reduced kilohm-range sensitivity caused by the elevated anti-noise threshold.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19731-19749
Diagonal Asymmetric Phase-Shift Modulation Based Fault-Tolerant Method for Magnetic Network-Based Energy Router Under Switch Open-Circuit Fault
Magnetic network-based energy router (MNER) is a promising solution for integrating multiple energy sources, storages, and loads due to its high efficiency and controllability. However, the open-circuit fault (OCF) within MNER would threaten its reliability and must be eliminated promptly. Conventional fault-tolerant methods are constrained in simultaneously eliminating current bias and maintaining bidirectional power transfer. This paper proposes a fault-tolerant method based on diagonal-asymmetric phase-shift modulation (DAPSM) to achieve both objectives simultaneously. In the proposed method, the specific diagonal in fault bridge is effectively detected by extracting midpoint voltages. Upon detection, an internal phase-shift angle is employed to the complementary diagonal in the fault bridge, thereby reconfiguring the modulation strategy to DAPSM. The modulation reconfiguration equalizes the conduction time between healthy and faulty diagonals, and preserves the essential paths for power transfer. As a result, the winding current bias is eliminated and bidirectional power transfer is maintained simultaneously. A 3-kW MNER experimental platform was constructed to verify the effectiveness of both the fault detection and fault-tolerant method.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (11) , 19731-19749
Diagonal Asymmetric Phase-Shift Modulation Based Fault-Tolerant Method for Magnetic Network-Based Energy Router Under Switch Open-Circuit Fault
Magnetic network-based energy router (MNER) is a promising solution for integrating multiple energy sources, storages, and loads due to its high efficiency and controllability. However, the open-circuit fault (OCF) within MNER would threaten its reliability and must be eliminated promptly. Conventional fault-tolerant methods are constrained in simultaneously eliminating current bias and maintaining bidirectional power transfer. This paper proposes a fault-tolerant method based on diagonal-asymmetric phase-shift modulation (DAPSM) to achieve both objectives simultaneously. In the proposed method, the specific diagonal in fault bridge is effectively detected by extracting midpoint voltages. Upon detection, an internal phase-shift angle is employed to the complementary diagonal in the fault bridge, thereby reconfiguring the modulation strategy to DAPSM. The modulation reconfiguration equalizes the conduction time between healthy and faulty diagonals, and preserves the essential paths for power transfer. As a result, the winding current bias is eliminated and bidirectional power transfer is maintained simultaneously. A 3-kW MNER experimental platform was constructed to verify the effectiveness of both the fault detection and fault-tolerant method.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 13 (2) , 59-66
Bio-Inspired Power Electronics Systems: A Path Toward Extreme Resiliency
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 13 (2) , 59-66
Bio-Inspired Power Electronics Systems: A Path Toward Extreme Resiliency
- Open Access
- 12 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 781
BP Neural Network-Based Adaptive Phase-Locked Loop for Impedance Measurement with Dynamic Operating Conditions
With the development of modern power systems, impedance measurement has become a key approach for stability assessment of power-electronic-dominated grids. In particular, frequency-sweep–based impedance measurement is widely adopted due to its effectiveness in characterizing system dynamics. However, owing to the limited adaptability of conventional phase-locked loop (PLL), grid-following (GFL) converters encounter significant challenges in maintaining stable operation during frequency-sweep signal injection, especially under non-power-frequency excitation and grid disturbances. To address these issues, this paper proposes an adaptive PLL scheme based on a backpropagation (BP) neural network. This scheme fully leverages the nonlinear mapping and adaptive learning capabilities of the BP neural network, which significantly enhances the robustness and stability adaptability of the synchronization component against small disturbances during the impedance measurement process. A hybrid strategy combining offline parameter tuning and online adaptive adjustment is adopted to improve reliability under varying operating conditions. Comprehensive simulation studies and hardware-in-the-loop (HIL) experimental results verify the effectiveness of the proposed method in improving stability and impedance measurement accuracy in frequency-sweep–based applications.
- 12 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 781
Open AccessBP Neural Network-Based Adaptive Phase-Locked Loop for Impedance Measurement with Dynamic Operating Conditions
With the development of modern power systems, impedance measurement has become a key approach for stability assessment of power-electronic-dominated grids. In particular, frequency-sweep–based impedance measurement is widely adopted due to its effectiveness in characterizing system dynamics. However, owing to the limited adaptability of conventional phase-locked loop (PLL), grid-following (GFL) converters encounter significant challenges in maintaining stable operation during frequency-sweep signal injection, especially under non-power-frequency excitation and grid disturbances. To address these issues, this paper proposes an adaptive PLL scheme based on a backpropagation (BP) neural network. This scheme fully leverages the nonlinear mapping and adaptive learning capabilities of the BP neural network, which significantly enhances the robustness and stability adaptability of the synchronization component against small disturbances during the impedance measurement process. A hybrid strategy combining offline parameter tuning and online adaptive adjustment is adopted to improve reliability under varying operating conditions. Comprehensive simulation studies and hardware-in-the-loop (HIL) experimental results verify the effectiveness of the proposed method in improving stability and impedance measurement accuracy in frequency-sweep–based applications.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation
Stator winding insulation is one of the most fragile components in electric drive system. To prevent insulation-related failures, online condition monitoring of stator insulation is critical to ensure high reliability requirements in inverter-fed ac motors. Groundwall insulation monitoring can be achieved by common-mode (CM) measuring methods, which evaluate insulation by CM impedance spectrum shifts. However, CM impedance shows distinct insulation-related characteristics over broadband frequency range. In this article, insulation-related characteristics are revealed and compared by developing individual models in different frequency regions. Besides, a hybrid model-data driven method is proposed to achieve assessment of groundwall insulation in this article. Phase-to-ground and neutral-to-ground insulation are distinguished by pretrained network, which establishes the link between CM features and insulation capacitances. Experimental results have been conducted on inverter-fed induction machine with an accelerated aging procedure. The experiment results prove that the proposed method can achieve detection of groundwall insulation in real time.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Condition Monitoring of Stator Groundwall Insulation for AC Motors by Broadband Common-Mode Impedance Observation
Stator winding insulation is one of the most fragile components in electric drive system. To prevent insulation-related failures, online condition monitoring of stator insulation is critical to ensure high reliability requirements in inverter-fed ac motors. Groundwall insulation monitoring can be achieved by common-mode (CM) measuring methods, which evaluate insulation by CM impedance spectrum shifts. However, CM impedance shows distinct insulation-related characteristics over broadband frequency range. In this article, insulation-related characteristics are revealed and compared by developing individual models in different frequency regions. Besides, a hybrid model-data driven method is proposed to achieve assessment of groundwall insulation in this article. Phase-to-ground and neutral-to-ground insulation are distinguished by pretrained network, which establishes the link between CM features and insulation capacitances. Experimental results have been conducted on inverter-fed induction machine with an accelerated aging procedure. The experiment results prove that the proposed method can achieve detection of groundwall insulation in real time.
- Open Access
- 19 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (22) , 4528
Multi-Functional Impedance Measurement by Means of Fractional-Order Harmonic Injection
As power electronic converters increase in scale, impedance measurement has become critical for assessing system stability, detecting islanding, and performing other critical analyses. This paper derives the impedance from the voltage and current responses measured after controlled perturbations, employing d-q frame impedance matrices. A static var generator (SVG) with redundant capacity is employed as the perturbation source, and a fractional-order repetitive control (FORC) strategy is introduced to inject the multi-frequency signal efficiently, eliminating the need for additional hardware. By optimizing the perturbation design and suppressing the dynamic error of the phase-locked loop, the method achieves both convergence and accuracy. Comprehensive simulations and experiments validate the approach.
- 19 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (22) , 4528
Open AccessMulti-Functional Impedance Measurement by Means of Fractional-Order Harmonic Injection
As power electronic converters increase in scale, impedance measurement has become critical for assessing system stability, detecting islanding, and performing other critical analyses. This paper derives the impedance from the voltage and current responses measured after controlled perturbations, employing d-q frame impedance matrices. A static var generator (SVG) with redundant capacity is employed as the perturbation source, and a fractional-order repetitive control (FORC) strategy is introduced to inject the multi-frequency signal efficiently, eliminating the need for additional hardware. By optimizing the perturbation design and suppressing the dynamic error of the phase-locked loop, the method achieves both convergence and accuracy. Comprehensive simulations and experiments validate the approach.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 903-906
Enhanced Control for Transient Stability of Type-IV Grid-Forming Wind Turbines
Grid-Forming (GFM) wind turbines are susceptible to transient instability during grid faults. However, existing studies on the transient stability of GFM wind turbines mainly focus on the effects of the grid-side. In addition, the enhancement of transient stability in grid-forming wind turbines has received limited attention. This letter investigates the transient stability mechanisms of GFM wind turbines using the equal area criterion (EAC), considering the effects of machine-side and DC-link voltage control. Based on this analysis, a novel control strategy is proposed to enhance AC side transient stability by simultaneously optimizing machine-side and grid-side control, while preventing DC side overvoltage and undervoltage. Both the theoretical analysis and the proposed strategy are validated through experiments.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 41 (1) , 903-906
Enhanced Control for Transient Stability of Type-IV Grid-Forming Wind Turbines
Grid-Forming (GFM) wind turbines are susceptible to transient instability during grid faults. However, existing studies on the transient stability of GFM wind turbines mainly focus on the effects of the grid-side. In addition, the enhancement of transient stability in grid-forming wind turbines has received limited attention. This letter investigates the transient stability mechanisms of GFM wind turbines using the equal area criterion (EAC), considering the effects of machine-side and DC-link voltage control. Based on this analysis, a novel control strategy is proposed to enhance AC side transient stability by simultaneously optimizing machine-side and grid-side control, while preventing DC side overvoltage and undervoltage. Both the theoretical analysis and the proposed strategy are validated through experiments.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 2290-2302
Turn-OFF Delay Time Based Online Junction Temperature Monitoring for SiC MOSFETs Over Aging
Junction temperature (${T}_{j}$) is a crucial quantity for monitoring the working condition of semiconductors in power converter operation. Online ${T}_{j}$ measurement can be achieved by the thermo-sensitive electrical parameters (TSEPs), which should have an appropriate correspondence between itself and ${T}_{j}$. Among various TSEPs, the turn-off delay time (${t}_{d\_{\mathrm{off}}}$) shows good performance of sensitivity and linearity for online ${T}_{j}$ measurement. However, parameter offset may occur in TSEPs during the aging process of devices, which causes errors in temperature measurement. This article proposes an online condition monitoring method to achieve junction temperature assessment for SiC mosfets over aging. The error caused by aging can be eliminated by updating ${t}_{d\_{\mathrm{off}}}$ versus ${T}_{j}$ relationship with the proposed aging compensation method. Moreover, an auxiliary circuit is proposed for accurate and fast detection of ${t}_{d\_{\mathrm{off}}}$. Experimental results have been given to verify that the proposed condition monitoring method can achieve accurate temperature detection under both healthy conditions and aging conditions of SiC mosfets.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 2290-2302
Turn-OFF Delay Time Based Online Junction Temperature Monitoring for SiC MOSFETs Over Aging
Junction temperature (${T}_{j}$) is a crucial quantity for monitoring the working condition of semiconductors in power converter operation. Online ${T}_{j}$ measurement can be achieved by the thermo-sensitive electrical parameters (TSEPs), which should have an appropriate correspondence between itself and ${T}_{j}$. Among various TSEPs, the turn-off delay time (${t}_{d\_{\mathrm{off}}}$) shows good performance of sensitivity and linearity for online ${T}_{j}$ measurement. However, parameter offset may occur in TSEPs during the aging process of devices, which causes errors in temperature measurement. This article proposes an online condition monitoring method to achieve junction temperature assessment for SiC mosfets over aging. The error caused by aging can be eliminated by updating ${t}_{d\_{\mathrm{off}}}$ versus ${T}_{j}$ relationship with the proposed aging compensation method. Moreover, an auxiliary circuit is proposed for accurate and fast detection of ${t}_{d\_{\mathrm{off}}}$. Experimental results have been given to verify that the proposed condition monitoring method can achieve accurate temperature detection under both healthy conditions and aging conditions of SiC mosfets.