JTJian Tang

Jian Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jian Tang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Generalized Design Criterion of Filter-Based Stabilizing Control of ST-Fed LV Grid

    by Zhixiang Zou, Jian Tang, Shuai Yuan, Giampaolo Buticchi, Marco Liserre

    Despite the Smart Transformer’s (ST) significant advantages in addressing system-level challenges, control-level issues, especially stability issues arising from the increasing penetration of inverter-based renewables, remain crucial. Existing methods, like filter-based active damping and virtual impedance, have been explored in literature to improve the stability of low voltage (LV) ST-fed grids. However, most of these approaches are tailored to specific stability concerns, lacking the generality needed for comprehensive designs. To bridge this gap, this paper proposes a generalized filter-based stabilizing control for the ST LV converter, using the biquadratic filter. A general design criterion is proposed, grounded in pole-zero compensation within a multi-input multi-output (MIMO) system framework. This design criterion aims to determine an optimal stability region for parameter design, with the potential to be applied to a broader range of second-order filters with poles and zeros. Both theoretical analysis and testing validate the effectiveness of the proposed control strategy and design criterion.


  • A Unified Reduced-Order Approach for Grid-Interfaced DC/AC Converters

    by Zhixiang Zou, Ruokai Xu, Qilin Peng, Jian Tang, Giampaolo Buticchi

    Small-signal impedance/admittance models are vital for stability analysis in systems with dc/ac converters. However, these converters often have higher orders compared to conventional power system devices such as synchronous generators. This complexity can hinder the analysis of grids with a high penetration of converters. Existing model order reduction methods often rely on numerical approximations or piecewise models tailored to specific frequency bands, which have high complexity and limited practical applicability. To address these issues, this article proposes a unified model reduction approach for various grid converters, offering symbolic expressions and covering a wide frequency range up to the Nyquist frequency. The proposed model aims to simplify analysis without sacrificing accuracy, addressing the challenges posed by varying system parameters or operating points. The accuracy of the proposed model is validated through comprehensive theoretical analysis and experimental verification.

  • Reduced-Order Symbolic Admittance Model and Stability Analysis of Grid-Connected Converters

    by Zhixiang Zou, Ruokai Xu, Jian Tang, Wu Chen, Zheng Wang

    With the penetration of power electronic devices in the power grid, their multi-time scale coupling characteristic with the power grid leads to a decrease in the power system stability. To study this issue, small-signal impedance modeling and stability analysis are necessary for interconnected power electronic devices. However, with the increasing complexity of the control structure and power grid structure, the order of small-signal model transfer functions of power electronic systems becomes higher. Especially for systems with high-proportion grid-connected converters, modeling complexity rises exponentially. Traditional numerical simplified models make it difficult to cover the general scenarios where grid-connected converters work under different operating conditions and parameters. On the other hand, these models lack generality and clear physical significance. To solve the above issue, this paper proposes a novel symbolic order-reduction method for grid-connected converters in the wide frequency band (1 5000Hz), by decoupling and simplifying the control loops with different bandwidths in the full-order small-signal admittance model, which significantly reduces the order of the model with physical meanings retained. Based on the symbolic model, the corresponding RLC circuit model is subsequently provided, revealing a clearer system stability mechanism. Finally, the effectiveness of the method is demonstrated through theoretical analysis, simulation, and experimental verification.


  • Adaptive Stabilizing Control of Smart Transformer Based on Reinforcement Learning Optimization

    by Jian Tang, Zhixiang Zou, Jiajun Yang, Giampaolo Buticchi, Wei Hua

    The stability of power systems is currently facing significant challenges due to the increasing penetration of distributed energy resources (DERs). To improve stability, the smart transformer (ST) can be used to reshape the grid-side impedance that interacts with low-voltage (LV) side DER inverters by adjusting the control strategy. This paper first establishes the impedance models of the ST LV converter and DER inverter and analyzes the stability of the system. Specifically, the impact of the load and output power of the DER inverter on stability is investigated. A biquad filter-based active damping scheme is then adopted to improve system stability, with filter parameters pre-designed based on the root-locus curve. However, this design method is dependent on the system model and lacks adaptability, limiting the system stability region. To address this issue, this paper proposes using reinforcement learning (RL) algorithms to achieve adaptability in stabilizing control, as RL can achieve model-free training. The results show that the proposed approach can further broaden the region of stable operation for the system. Finally, simulations and experiments are used to demonstrate the effectiveness of adaptive stabilizing control.


  • Design of Stabilizing Control of Smart Transformer Using an Asymmetric Resonant Filter

    by Xingqi Liu, Zhixiang Zou, Yiyang Yao, Jian Tang, Wu Chen, Zheng Wang

    Smart transformer (ST) is usually used to solve system level problems. However, ST low-voltage sider converter will couple with the grid-connected converters and stability and harmonic oscillations problems occur. To solve this problem, this paper studies the filter impact on the stability and an asymmetric resonant filter is proposed. Based on the proposed filter, the stabilizing control strategy is proposed to make system perform better. The proposed control strategy has following advantages: 1) It can realize centralized control, and avoid complex calculations and operation processes; 2) Compared with other methods, the implementation method is relatively simple, only the harmonic frequency should be given. The simulation results is used to verify the the effectiveness of the proposed control strategy.

  • Robust Control of Smart Transformer-fed Grid

    by Zhixiang Zou, Jian Tang, Yi Zhang, Xingqi Liu, Zheng Wang, Ming Cheng

    The Smart Transformer (ST) is a solid-state transformer with control and communication functionalities, interfacing medium voltage and low voltage (LV) grids. The ST-fed grid has high potential to optimize power system and avoid or postpone the reinforcement of distribution networks. However, with the increasing utilization of power converters, the challenges in terms of system stability are encountered. To better understand the problems, this paper firstly develops the models of ST LV converter and grid-forming as well as grid-following converters used in the LV grid. Then, the stability of a ST-fed grid with different types of converters is studied by considering the effect of line impedance. To address the stability issues, a robust control strategy is proposed for the ST LV converter. Simulation results are provided to validate the effectiveness of the proposed control scheme.