Sanjeev G. Shroff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sanjeev G. Shroff has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Ramakrishna Mukkamala
University of Pittsburgh
5 shared publications - Hadi Daher
University of Pittsburgh
3 shared publications - Jonathan Kirk
Center for Cardiovascular Research, Department of Medicine, University of Chicago, Chicago, IL (M.M.D., J.A.K.).
3 shared publications - Mark Freithaler
Department of Bioengineering, University of Pittsburgh, USA
3 shared publications - Vishaal Dhamotharan
Department of Bioengineering, University of Pittsburgh, USA
3 shared publications - Alberto Avolio
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
2 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Elsevier in British Journal of Anaesthesia
Cardiac output monitoring using an automatic arm cuff device in surgical patients
- 5 November 2026
- Published by Elsevier in British Journal of Anaesthesia
Open AccessCardiac output monitoring using an automatic arm cuff device in surgical patients
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2425-2434
Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Investigation of the DC Component of PPG
Objective: Oscillometric finger pressing is a potential method for smartphone-based blood pressure (BP) monitoring. A photoplethysmography (PPG)-force sensor unit measures the slowly increasing finger pressure applied by the user under visual guidance and the resulting variable blood volume oscillations (“AC PPG”). BP can then be estimated from the oscillation height versus finger pressure function. The non-oscillating component of PPG (“DC PPG”) during oscillometric finger pressing was investigated. Methods: The total (AC+DC) PPG waveform, finger pressure, and ECG waveform during finger pressing were measured with a modified custom system along with arm cuff BP in volunteers. A mathematical model accounting for the arterial compliance curve and tissue compression was developed to explain the measured total PPG waveform versus finger pressure function. The model predicted that DC PPG (average of the total PPG over each heartbeat) versus finger pressure function will show a fiducial marker (bend) near finger systolic BP (SP). An algorithm was developed to detect this bend and estimate arm SP from the finger pressing measurements. Results: The model explained the measured total PPG waveform versus finger pressure function over the finger pressure range that is relevant to BP estimation. The model-based algorithm yielded a correlation coefficient of 0.90 and a precision error of 9.2 mmHg against cuff SP (N = 18). Conclusion: An easy-to-understand model can explain the total PPG waveform during finger pressing, and SP can be estimated from the DC (non-oscillating) PPG versus finger pressure function. Significance: These findings may prove useful in converting ubiquitous smartphones into BP sensors.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (7) , 2425-2434
Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Investigation of the DC Component of PPG
Objective: Oscillometric finger pressing is a potential method for smartphone-based blood pressure (BP) monitoring. A photoplethysmography (PPG)-force sensor unit measures the slowly increasing finger pressure applied by the user under visual guidance and the resulting variable blood volume oscillations (“AC PPG”). BP can then be estimated from the oscillation height versus finger pressure function. The non-oscillating component of PPG (“DC PPG”) during oscillometric finger pressing was investigated. Methods: The total (AC+DC) PPG waveform, finger pressure, and ECG waveform during finger pressing were measured with a modified custom system along with arm cuff BP in volunteers. A mathematical model accounting for the arterial compliance curve and tissue compression was developed to explain the measured total PPG waveform versus finger pressure function. The model predicted that DC PPG (average of the total PPG over each heartbeat) versus finger pressure function will show a fiducial marker (bend) near finger systolic BP (SP). An algorithm was developed to detect this bend and estimate arm SP from the finger pressing measurements. Results: The model explained the measured total PPG waveform versus finger pressure function over the finger pressure range that is relevant to BP estimation. The model-based algorithm yielded a correlation coefficient of 0.90 and a precision error of 9.2 mmHg against cuff SP (N = 18). Conclusion: An easy-to-understand model can explain the total PPG waveform during finger pressing, and SP can be estimated from the DC (non-oscillating) PPG versus finger pressure function. Significance: These findings may prove useful in converting ubiquitous smartphones into BP sensors.
- Top Cited Papers
- 1 June 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (6) , 957-970
Cuffless Blood Pressure Measurement: Where Do We Actually Stand?
Cuffless blood pressure (BP) measurement offers considerable potential for clinical practice but is a challenging technological field. Many are investigating pulse wave analysis with or without pulse arrival time in which machine learning is applied to pulsatile waveforms obtained with mobile devices (eg, wristbands, smartphones) to estimate BP. These methods generally require individual user calibration with cuff BP measurements or demographics (eg, age, sex). This calibration makes it difficult to evaluate the method’s accuracy, and many studies claiming accuracy used inadequate testing procedures. Yet, publications and regulatory-cleared devices continue to rise, seemingly implying technological advancements. An update is provided on the flurry of activity in cuffless BP technologies over the last 2 to 3 years, covering the clinical need, the latest devices, recent publications based on pulse wave analysis and pulse arrival time, progress in developing validation standards for cuffless BP devices, and recent publications on other cuffless BP measurement principles. Despite the high volume of research and development, to date, there is no compelling evidence that pulse wave analysis and pulse arrival time can provide significant added value in BP measurement accuracy beyond the cuff BP or demographic data for calibration. Thus, it is reasonable to at least be skeptical of published and future studies on pulse wave analysis and pulse arrival time for cuffless BP measurement with uncertain testing procedures. It is important to focus on establishing robust validation standards for cuffless BP devices requiring individual user calibration and also pursuing cuffless and calibration-free BP measurement methodologies going forward.
- 1 June 2025
- Published by Wolters Kluwer Health in Hypertension
- Vol. 82 (6) , 957-970
Top Cited PapersCuffless Blood Pressure Measurement: Where Do We Actually Stand?
Cuffless blood pressure (BP) measurement offers considerable potential for clinical practice but is a challenging technological field. Many are investigating pulse wave analysis with or without pulse arrival time in which machine learning is applied to pulsatile waveforms obtained with mobile devices (eg, wristbands, smartphones) to estimate BP. These methods generally require individual user calibration with cuff BP measurements or demographics (eg, age, sex). This calibration makes it difficult to evaluate the method’s accuracy, and many studies claiming accuracy used inadequate testing procedures. Yet, publications and regulatory-cleared devices continue to rise, seemingly implying technological advancements. An update is provided on the flurry of activity in cuffless BP technologies over the last 2 to 3 years, covering the clinical need, the latest devices, recent publications based on pulse wave analysis and pulse arrival time, progress in developing validation standards for cuffless BP devices, and recent publications on other cuffless BP measurement principles. Despite the high volume of research and development, to date, there is no compelling evidence that pulse wave analysis and pulse arrival time can provide significant added value in BP measurement accuracy beyond the cuff BP or demographic data for calibration. Thus, it is reasonable to at least be skeptical of published and future studies on pulse wave analysis and pulse arrival time for cuffless BP measurement with uncertain testing procedures. It is important to focus on establishing robust validation standards for cuffless BP devices requiring individual user calibration and also pursuing cuffless and calibration-free BP measurement methodologies going forward.
- 16 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (9) , 2708-2717
Nonlinear Viscoelastic Modeling of Finger Arteries: Toward Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method
Objective: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. Methods: Nonlinear viscoelastic models relating transmural pressure (finger BP – applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm. Results: A Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%–34.0%) vs 50.9% (46.7%–53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency ( r = −0.8) and could thus possibly be used to compensate for viscoelasticity. Conclusion: Finger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. Significance: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.
- 16 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (9) , 2708-2717
Nonlinear Viscoelastic Modeling of Finger Arteries: Toward Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method
Objective: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. Methods: Nonlinear viscoelastic models relating transmural pressure (finger BP – applied pressure) to PPG oscillations during finger pressing were developed. The output of each model to a measured transmural pressure input was fitted to measured PPG oscillations from 15 participants. A parametric sensitivity analysis was performed via model simulations to elucidate the viscoelastic effect on the derivative-based BP computation algorithm. Results: A Wiener viscoelastic model comprising a first-order transfer function followed by a static sigmoidal function fitted the measured PPG oscillations better than an elastic model containing only the static function (median (IQR) error of 30.5% (25.6%–34.0%) vs 50.9% (46.7%–53.7%); p<0.01). In Wiener model simulations, the derivative algorithm underestimated SP, especially with high pulse pressure and low transfer function cutoff frequency (i.e., greater viscoelasticity). The mean of the normalized PPG waveform at the maximum oscillation beat was found to correlate with the cutoff frequency ( r = −0.8) and could thus possibly be used to compensate for viscoelasticity. Conclusion: Finger artery viscoelasticity negatively impacts oscillometric BP computation algorithms but can potentially be compensated for using available measurements. Significance: These findings may help in converting smartphones into truly cuffless BP monitors for improving hypertension awareness and control.
- Open Access
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 1-13
Grand Challenges at the Interface of Engineering and Medicine
Over the past two decades Biomedical Engineering has emerged as a major discipline that bridges societal needs of human health care with the development of novel technologies. Every medical institution is now equipped at varying degrees of sophistication with the ability to monitor human health in both non-invasive and invasive modes. The multiple scales at which human physiology can be interrogated provide a profound perspective on health and disease. We are at the nexus of creating “avatars” (herein defined as an extension of “digital twins”) of human patho/physiology to serve as paradigms for interrogation and potential intervention. Motivated by the emergence of these new capabilities, the IEEE Engineering in Medicine and Biology Society, the Departments of Biomedical Engineering at Johns Hopkins University and Bioengineering at University of California at San Diego sponsored an interdisciplinary workshop to define the grand challenges that face biomedical engineering and the mechanisms to address these challenges. The Workshop identified five grand challenges with cross-cutting themes and provided a roadmap for new technologies, identified new training needs, and defined the types of interdisciplinary teams needed for addressing these challenges. The themes presented in this paper include: 1) accumedicine through creation of avatars of cells, tissues, organs and whole human; 2) development of smart and responsive devices for human function augmentation; 3) exocortical technologies to understand brain function and treat neuropathologies; 4) the development of approaches to harness the human immune system for health and wellness; and 5) new strategies to engineer genomes and cells.
- 21 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 1-13
Open AccessGrand Challenges at the Interface of Engineering and Medicine
Over the past two decades Biomedical Engineering has emerged as a major discipline that bridges societal needs of human health care with the development of novel technologies. Every medical institution is now equipped at varying degrees of sophistication with the ability to monitor human health in both non-invasive and invasive modes. The multiple scales at which human physiology can be interrogated provide a profound perspective on health and disease. We are at the nexus of creating “avatars” (herein defined as an extension of “digital twins”) of human patho/physiology to serve as paradigms for interrogation and potential intervention. Motivated by the emergence of these new capabilities, the IEEE Engineering in Medicine and Biology Society, the Departments of Biomedical Engineering at Johns Hopkins University and Bioengineering at University of California at San Diego sponsored an interdisciplinary workshop to define the grand challenges that face biomedical engineering and the mechanisms to address these challenges. The Workshop identified five grand challenges with cross-cutting themes and provided a roadmap for new technologies, identified new training needs, and defined the types of interdisciplinary teams needed for addressing these challenges. The themes presented in this paper include: 1) accumedicine through creation of avatars of cells, tissues, organs and whole human; 2) development of smart and responsive devices for human function augmentation; 3) exocortical technologies to understand brain function and treat neuropathologies; 4) the development of approaches to harness the human immune system for health and wellness; and 5) new strategies to engineer genomes and cells.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (11) , 3052-3063
Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Analysis of Oscillation Width Variations Can Improve Diastolic Pressure Computation
Objective: Oscillometric finger pressing is a potential method for absolute blood pressure (BP) monitoring via a smartphone. The user presses their fingertip against a photoplethysmography-force sensor unit on a smartphone to steadily increase the external pressure on the underlying artery. Meanwhile, the phone guides the finger pressing and computes systolic BP (SP) and diastolic BP (DP) from the measured blood volume oscillations and finger pressure. The objective was to develop and evaluate reliable finger oscillometric BP computation algorithms. Methods: The collapsibility of thin finger arteries was exploited in an oscillometric model to develop simple algorithms for computing BP from the finger pressing measurements. These algorithms extract features from “width” oscillograms (oscillation width versus finger pressure functions) and the conventional “height” oscillogram for markers of DP and SP. Finger pressing measurements were obtained using a custom system along with reference arm cuff BP measurements from 22 subjects. Measurements were also obtained during BP interventions in some subjects for 34 total measurements. Results: An algorithm employing the average of width and height oscillogram features predicted DP with correlation of 0.86 and precision error of 8.6 mmHg with respect to the reference measurements. Analysis of arm oscillometric cuff pressure waveforms from an existing patient database provided evidence that the width oscillogram features are better suited to finger oscillometry. Conclusion: Analysis of oscillation width variations during finger pressing can improve DP computation. Significance: The study findings may help in converting widely available devices into truly cuffless BP monitors for improving hypertension awareness and control.
- 17 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (11) , 3052-3063
Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Analysis of Oscillation Width Variations Can Improve Diastolic Pressure Computation
Objective: Oscillometric finger pressing is a potential method for absolute blood pressure (BP) monitoring via a smartphone. The user presses their fingertip against a photoplethysmography-force sensor unit on a smartphone to steadily increase the external pressure on the underlying artery. Meanwhile, the phone guides the finger pressing and computes systolic BP (SP) and diastolic BP (DP) from the measured blood volume oscillations and finger pressure. The objective was to develop and evaluate reliable finger oscillometric BP computation algorithms. Methods: The collapsibility of thin finger arteries was exploited in an oscillometric model to develop simple algorithms for computing BP from the finger pressing measurements. These algorithms extract features from “width” oscillograms (oscillation width versus finger pressure functions) and the conventional “height” oscillogram for markers of DP and SP. Finger pressing measurements were obtained using a custom system along with reference arm cuff BP measurements from 22 subjects. Measurements were also obtained during BP interventions in some subjects for 34 total measurements. Results: An algorithm employing the average of width and height oscillogram features predicted DP with correlation of 0.86 and precision error of 8.6 mmHg with respect to the reference measurements. Analysis of arm oscillometric cuff pressure waveforms from an existing patient database provided evidence that the width oscillogram features are better suited to finger oscillometry. Conclusion: Analysis of oscillation width variations during finger pressing can improve DP computation. Significance: The study findings may help in converting widely available devices into truly cuffless BP monitors for improving hypertension awareness and control.
- Open Access
- 13 March 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1070498
Subject-specific factors affecting particle residence time distribution of left atrial appendage in atrial fibrillation: A computational model-based study
Background: Atrial fibrillation (AF) is a prevalent arrhythmia, that causes thrombus formation, ordinarily in the left atrial appendage (LAA). The conventional metric of stroke risk stratification, CHA2DS2-VASc score, does not account for LAA morphology or hemodynamics. We showed in our previous study that residence time distribution (RTD) of blood-borne particles in the LAA and its associated calculated variables (i.e., mean residence time, tm, and asymptotic concentration, C∞) have the potential to improve CHA2DS2-VASc score. The purpose of this research was to investigate the effects of the following potential confounding factors on LAA tm and C∞: (1) pulmonary vein flow waveform pulsatility, (2) non-Newtonian blood rheology and hematocrit level, and (3) length of the simulation.Methods: Subject-Specific data including left atrial (LA) and LAA cardiac computed tomography, cardiac output (CO), heart rate, and hematocrit level were gathered from 25 AF subjects. We calculated LAA tm and C∞ based on series of computational fluid dynamics (CFD) analyses.Results: Both LAA tm and C∞ are significantly affected by the CO, but not by temporal pattern of the inlet flow. Both LAA tm and C∞ increase with increasing hematocrit level and both calculated indices are higher for non-Newtonian blood rheology for a given hematocrit level. Further, at least 20,000 s of CFD simulation is needed to calculate LAA tm and C∞ values reliably.Conclusions: Subject-specific LA and LAA geometries, CO, and hematocrit level are essential to quantify the subject-specific proclivity of blood cell tarrying inside LAA in terms of the RTD function.
- 13 March 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1070498
Open AccessSubject-specific factors affecting particle residence time distribution of left atrial appendage in atrial fibrillation: A computational model-based study
Background: Atrial fibrillation (AF) is a prevalent arrhythmia, that causes thrombus formation, ordinarily in the left atrial appendage (LAA). The conventional metric of stroke risk stratification, CHA2DS2-VASc score, does not account for LAA morphology or hemodynamics. We showed in our previous study that residence time distribution (RTD) of blood-borne particles in the LAA and its associated calculated variables (i.e., mean residence time, tm, and asymptotic concentration, C∞) have the potential to improve CHA2DS2-VASc score. The purpose of this research was to investigate the effects of the following potential confounding factors on LAA tm and C∞: (1) pulmonary vein flow waveform pulsatility, (2) non-Newtonian blood rheology and hematocrit level, and (3) length of the simulation.Methods: Subject-Specific data including left atrial (LA) and LAA cardiac computed tomography, cardiac output (CO), heart rate, and hematocrit level were gathered from 25 AF subjects. We calculated LAA tm and C∞ based on series of computational fluid dynamics (CFD) analyses.Results: Both LAA tm and C∞ are significantly affected by the CO, but not by temporal pattern of the inlet flow. Both LAA tm and C∞ increase with increasing hematocrit level and both calculated indices are higher for non-Newtonian blood rheology for a given hematocrit level. Further, at least 20,000 s of CFD simulation is needed to calculate LAA tm and C∞ values reliably.Conclusions: Subject-specific LA and LAA geometries, CO, and hematocrit level are essential to quantify the subject-specific proclivity of blood cell tarrying inside LAA in terms of the RTD function.
- Top Cited Papers
- 1 March 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (3) , 534-540
The Microsoft Research Aurora Project: Important Findings on Cuffless Blood Pressure Measurement
Conventional blood pressure (BP) measurement devices based on an inflatable cuff only provide a narrow view of the continuous BP profile. Cuffless BP measuring technologies could permit numerous BP readings throughout daily life and thereby considerably improve the assessment and management of hypertension. Several wearable cuffless BP devices based on pulse wave analysis (applied to a photoplethysmography or tonometry waveform) with or without use of pulse arrival time are now available on the market. The key question is: Can these devices provide accurate measurement of BP? Microsoft Research recently published a complex article describing perhaps the most important and highest resource project to date (Aurora Project) on assessing the accuracy of several pulse wave analysis and pulse wave analysis-pulse arrival time devices. The overall results from 1125 participants were clear-cut negative. The present article motivates and describes emerging cuffless BP devices and then summarizes the Aurora Project. The study methodology and findings are next discussed in the context of regulatory-cleared devices, physiology, and related studies, and the study strengths and limitations are pinpointed thereafter. Finally, the implications of the Aurora Project are briefly stated and recommendations for future work are offered to finally realize the considerable potential of cuffless BP measurement in health care.
- 1 March 2023
- Published by Wolters Kluwer Health in Hypertension
- Vol. 80 (3) , 534-540
Top Cited PapersThe Microsoft Research Aurora Project: Important Findings on Cuffless Blood Pressure Measurement
Conventional blood pressure (BP) measurement devices based on an inflatable cuff only provide a narrow view of the continuous BP profile. Cuffless BP measuring technologies could permit numerous BP readings throughout daily life and thereby considerably improve the assessment and management of hypertension. Several wearable cuffless BP devices based on pulse wave analysis (applied to a photoplethysmography or tonometry waveform) with or without use of pulse arrival time are now available on the market. The key question is: Can these devices provide accurate measurement of BP? Microsoft Research recently published a complex article describing perhaps the most important and highest resource project to date (Aurora Project) on assessing the accuracy of several pulse wave analysis and pulse wave analysis-pulse arrival time devices. The overall results from 1125 participants were clear-cut negative. The present article motivates and describes emerging cuffless BP devices and then summarizes the Aurora Project. The study methodology and findings are next discussed in the context of regulatory-cleared devices, physiology, and related studies, and the study strengths and limitations are pinpointed thereafter. Finally, the implications of the Aurora Project are briefly stated and recommendations for future work are offered to finally realize the considerable potential of cuffless BP measurement in health care.
- Open Access
- 11 May 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Subject-Specific Calculation of Left Atrial Appendage Blood-Borne Particle Residence Time Distribution in Atrial Fibrillation
Atrial fibrillation (AF) is the most common arrhythmia that leads to thrombus formation, mostly in the left atrial appendage (LAA). The current standard of stratifying stroke risk, based on the CHA2DS2-VASc score, does not consider LAA morphology, and the clinically accepted LAA morphology-based classification is highly subjective. The aim of this study was to determine whether LAA blood-borne particle residence time distribution and the proposed quantitative index of LAA 3D geometry can add independent information to the CHA2DS2-VASc score. Data were collected from 16 AF subjects. Subject-specific measurements included left atrial (LA) and LAA 3D geometry obtained by cardiac computed tomography, cardiac output, and heart rate. We quantified 3D LAA appearance in terms of a novel LAA appearance complexity index (LAA-ACI). We employed computational fluid dynamics analysis and a systems-based approach to quantify residence time distribution and associated calculated variable (LAA mean residence time, tm) in each subject. The LAA-ACI captured the subject-specific LAA 3D geometry in terms of a single number. LAA tm varied significantly within a given LAA morphology as defined by the current subjective method and it was not simply a reflection of LAA geometry/appearance. In addition, LAA-ACI and LAA tm varied significantly for a given CHA2DS2-VASc score, indicating that these two indices of stasis are not simply a reflection of the subjects' clinical status. We conclude that LAA-ACI and LAA tm add independent information to the CHA2DS2-VASc score about stasis risk and thereby can potentially enhance its ability to stratify stroke risk in AF patients.
- 11 May 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12
Open AccessSubject-Specific Calculation of Left Atrial Appendage Blood-Borne Particle Residence Time Distribution in Atrial Fibrillation
Atrial fibrillation (AF) is the most common arrhythmia that leads to thrombus formation, mostly in the left atrial appendage (LAA). The current standard of stratifying stroke risk, based on the CHA2DS2-VASc score, does not consider LAA morphology, and the clinically accepted LAA morphology-based classification is highly subjective. The aim of this study was to determine whether LAA blood-borne particle residence time distribution and the proposed quantitative index of LAA 3D geometry can add independent information to the CHA2DS2-VASc score. Data were collected from 16 AF subjects. Subject-specific measurements included left atrial (LA) and LAA 3D geometry obtained by cardiac computed tomography, cardiac output, and heart rate. We quantified 3D LAA appearance in terms of a novel LAA appearance complexity index (LAA-ACI). We employed computational fluid dynamics analysis and a systems-based approach to quantify residence time distribution and associated calculated variable (LAA mean residence time, tm) in each subject. The LAA-ACI captured the subject-specific LAA 3D geometry in terms of a single number. LAA tm varied significantly within a given LAA morphology as defined by the current subjective method and it was not simply a reflection of LAA geometry/appearance. In addition, LAA-ACI and LAA tm varied significantly for a given CHA2DS2-VASc score, indicating that these two indices of stasis are not simply a reflection of the subjects' clinical status. We conclude that LAA-ACI and LAA tm add independent information to the CHA2DS2-VASc score about stasis risk and thereby can potentially enhance its ability to stratify stroke risk in AF patients.
- 24 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10133, 101332C-101332C-9
Personalized design and virtual evaluation of physician-modified stent grafts for juxta-renal abdominal aortic aneurysms
- 24 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10133, 101332C-101332C-9
Personalized design and virtual evaluation of physician-modified stent grafts for juxta-renal abdominal aortic aneurysms