Jinlong Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jinlong Liu has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Jun Zhang
6 shared publicationsWei Liu
6 shared publicationsZongjin Ren
6 shared publications- Wei Liu
Dalian University of Technology
5 shared publications - Jun Zhang
Dalian University of Technology
4 shared publications Shilu Mai
4 shared publications
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 23724-23734
Development of a Piezoelectric Force Sensor for Space Microvibration Measurement
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 23724-23734
Development of a Piezoelectric Force Sensor for Space Microvibration Measurement
- 24 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Research on self-load-sharing piezoelectric three-component force sensor
- 24 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Research on self-load-sharing piezoelectric three-component force sensor
- Open Access
- 14 May 2026
- Published by Elsevier in SSRN Electronic Journal
Research on Self-load-sharing Piezoelectric Three-component Force Sensor
To address the technical challenges of increased sensor size and degraded dynamic performance associated with range extension in load-sharing sensors, this paper proposes a Self-load-sharing sensor device capable of handling high loads, exhibiting high dynamic performance, and featuring a compact design. By applying the principle of deformation-coordinated parallel load sharing, we construct theoretical mechanical models for the axial and shear directions of the Self-load-sharing sensor and identify the key factors influencing sensor range extension. Furthermore, finite element analysis was employed to simulate step loading and natural frequency responses, verifying the device’s capability for high-load and high-frequency dynamic response. After fabricating the self-load-sharing sensor, static and dynamic calibration tests were conducted using a proprietary calibration setup. Experimental results demonstrate that the self-load-sharing sensor exhibits excellent static and dynamic performance, with nonlinearity below 1%, repeatability error below 0.1%, and natural frequencies in all three directions exceeding 7200 Hz. Compared to traditional load-sharing sensors, it occupies less space and offers superior dynamic performance. Based on these findings, the mechanical force transmission process was analyzed to identify the causes of variations in the sensor’s actual load-sharing performance. An analysis of the measurement uncertainty for the self-load-sharing sensor revealed that the expanded uncertainty for all three force components does not exceed 1%, meeting the specified testing requirements. This research lays the foundation for the further optimization of load-sharing methods and high-performance design of piezoelectric sensors in the future, and holds significant practical application value.
- 14 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessResearch on Self-load-sharing Piezoelectric Three-component Force Sensor
To address the technical challenges of increased sensor size and degraded dynamic performance associated with range extension in load-sharing sensors, this paper proposes a Self-load-sharing sensor device capable of handling high loads, exhibiting high dynamic performance, and featuring a compact design. By applying the principle of deformation-coordinated parallel load sharing, we construct theoretical mechanical models for the axial and shear directions of the Self-load-sharing sensor and identify the key factors influencing sensor range extension. Furthermore, finite element analysis was employed to simulate step loading and natural frequency responses, verifying the device’s capability for high-load and high-frequency dynamic response. After fabricating the self-load-sharing sensor, static and dynamic calibration tests were conducted using a proprietary calibration setup. Experimental results demonstrate that the self-load-sharing sensor exhibits excellent static and dynamic performance, with nonlinearity below 1%, repeatability error below 0.1%, and natural frequencies in all three directions exceeding 7200 Hz. Compared to traditional load-sharing sensors, it occupies less space and offers superior dynamic performance. Based on these findings, the mechanical force transmission process was analyzed to identify the causes of variations in the sensor’s actual load-sharing performance. An analysis of the measurement uncertainty for the self-load-sharing sensor revealed that the expanded uncertainty for all three force components does not exceed 1%, meeting the specified testing requirements. This research lays the foundation for the further optimization of load-sharing methods and high-performance design of piezoelectric sensors in the future, and holds significant practical application value.
- 12 May 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 323
Multi-dimensional force measurement method based on load balancing
- 12 May 2026
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 323
Multi-dimensional force measurement method based on load balancing
- 9 May 2026
- Published by Elsevier in Acta Astronautica
- Vol. 247, 254-267
Study on error decoupling and in-situ calibration performance of thrust measurement system for attitude and orbit control engine
- 9 May 2026
- Published by Elsevier in Acta Astronautica
- Vol. 247, 254-267
Study on error decoupling and in-situ calibration performance of thrust measurement system for attitude and orbit control engine
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 17 September 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 239
Design and performance study of a piezoelectric force measuring device with large range and high stiffness
- 17 September 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 239
Design and performance study of a piezoelectric force measuring device with large range and high stiffness
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32209-32216
Research on the Calibration Performance With Variable Loading Points of the Eight-Point Distributed Wind Tunnel Piezoelectric Balance for Measuring Aerodynamic Forces on Hypersonic Vehicles
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (17) , 32209-32216
Research on the Calibration Performance With Variable Loading Points of the Eight-Point Distributed Wind Tunnel Piezoelectric Balance for Measuring Aerodynamic Forces on Hypersonic Vehicles
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.