Jun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jun Zhang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Zongjin Ren
School of Mechanical Engineering, Dalian University of Technology (DUT), Dalian, China
7 shared publications- Wei Liu
Dalian University of Technology
6 shared publications Yu Tian
Dalian University of Technology, Dalian, China
6 shared publicationsZhenyuan Jia
Chinese Academy of Sciences, Beijing, China
6 shared publications- Zongjin Ren
Dalian University of Technology
5 shared publications - Jinlong Liu
Dalian University of Technology
4 shared publications
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 23724-23734
Development of a Piezoelectric Force Sensor for Space Microvibration Measurement
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 23724-23734
Development of a Piezoelectric Force Sensor for Space Microvibration Measurement
- Open Access
- 14 May 2026
- Published by Elsevier in SSRN Electronic Journal
Research on Self-load-sharing Piezoelectric Three-component Force Sensor
To address the technical challenges of increased sensor size and degraded dynamic performance associated with range extension in load-sharing sensors, this paper proposes a Self-load-sharing sensor device capable of handling high loads, exhibiting high dynamic performance, and featuring a compact design. By applying the principle of deformation-coordinated parallel load sharing, we construct theoretical mechanical models for the axial and shear directions of the Self-load-sharing sensor and identify the key factors influencing sensor range extension. Furthermore, finite element analysis was employed to simulate step loading and natural frequency responses, verifying the device’s capability for high-load and high-frequency dynamic response. After fabricating the self-load-sharing sensor, static and dynamic calibration tests were conducted using a proprietary calibration setup. Experimental results demonstrate that the self-load-sharing sensor exhibits excellent static and dynamic performance, with nonlinearity below 1%, repeatability error below 0.1%, and natural frequencies in all three directions exceeding 7200 Hz. Compared to traditional load-sharing sensors, it occupies less space and offers superior dynamic performance. Based on these findings, the mechanical force transmission process was analyzed to identify the causes of variations in the sensor’s actual load-sharing performance. An analysis of the measurement uncertainty for the self-load-sharing sensor revealed that the expanded uncertainty for all three force components does not exceed 1%, meeting the specified testing requirements. This research lays the foundation for the further optimization of load-sharing methods and high-performance design of piezoelectric sensors in the future, and holds significant practical application value.
- 14 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessResearch on Self-load-sharing Piezoelectric Three-component Force Sensor
To address the technical challenges of increased sensor size and degraded dynamic performance associated with range extension in load-sharing sensors, this paper proposes a Self-load-sharing sensor device capable of handling high loads, exhibiting high dynamic performance, and featuring a compact design. By applying the principle of deformation-coordinated parallel load sharing, we construct theoretical mechanical models for the axial and shear directions of the Self-load-sharing sensor and identify the key factors influencing sensor range extension. Furthermore, finite element analysis was employed to simulate step loading and natural frequency responses, verifying the device’s capability for high-load and high-frequency dynamic response. After fabricating the self-load-sharing sensor, static and dynamic calibration tests were conducted using a proprietary calibration setup. Experimental results demonstrate that the self-load-sharing sensor exhibits excellent static and dynamic performance, with nonlinearity below 1%, repeatability error below 0.1%, and natural frequencies in all three directions exceeding 7200 Hz. Compared to traditional load-sharing sensors, it occupies less space and offers superior dynamic performance. Based on these findings, the mechanical force transmission process was analyzed to identify the causes of variations in the sensor’s actual load-sharing performance. An analysis of the measurement uncertainty for the self-load-sharing sensor revealed that the expanded uncertainty for all three force components does not exceed 1%, meeting the specified testing requirements. This research lays the foundation for the further optimization of load-sharing methods and high-performance design of piezoelectric sensors in the future, and holds significant practical application value.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 1 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (8) , 11679-11687
Design and Performance Research of a Spindle-Integrated Rotational Piezoelectric Testing System for Upset Force Measurement During Welding Processes
Accurate monitoring of high-frequency upset force during friction stir welding (FSW) is a critical step for optimizing welding process parameters and ensuring joint quality. However, traditional platform-type force gauges cannot measure the upset force in the bobbin tool friction stir welding (BT-FSW) process, which poses a technical challenge. To resolve this issue, a high-frequency spindle-integrated rotational piezoelectric testing system (SIR-PTS) mounted on the equipment spindle was designed. This system uses piezoelectric sensors as measuring elements and comprises a force gauge, a built-in signal conditioning circuit, and monitoring software. First, a theoretical mechanical model under rotational conditions was established to determine the dimensional parameters of the piezoelectric quartz wafers. Subsequently, ANSYS finite element simulation was utilized to analyze the static structural characteristics and dynamic response of the testing system. Meanwhile, a modular hardware circuit integrating charge conversion, filtering, and wireless transmission functions was developed. A series of verification experiments were conducted to evaluate the system performance. The experimental results demonstrate that the system exhibits a static linearity error of 0.64% and a repeatability error of 0.34%. Its main-direction natural frequency is 2082.52 Hz, which meets the requirements of high-frequency dynamic testing. These results confirm that the system can realize high-precision, real-time dynamic monitoring of upset force in BT-FSW processes.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error
The rotor system is a crucial component in the design and manufacture of helicopters. The accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this article presents a rotor balance based on the piezoelectric measurement principle for precise the measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Second, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14929-14940
Research on Piezoelectric Sensor for Micro Friction Measurement Based on Torque Amplification
The accurate measurement of surface friction resistance is crucial in the design of hypersonic vehicles, given its significant impact on the overall performance. To fulfill the stringent requirements of high sensitivity and resistance to normal force interference during testing, the present study introduces a novel approach for directly measuring surface micro friction force. This approach utilizes torque amplification principles based on the torsion characteristics of quartz wafer. Firstly, a detailed analysis is conducted to investigate the relationship between sensor stress and the measured force. This examination reveals the governing stress law on the wafer surface. Subsequently, by leveraging the force-to-electric conversion principle of quartz crystal, an accurate charge output model is established for the wafer when subjected to an input force. Simulation analysis is performed to validate the obtained results and to further explore the charge output behavior of the wafer under normal surface pressure. Secondly, the design of the surface friction measurement structure is meticulously carried out. This measurement structure is then subjected to rigorous static calibration and positive pressure interference verification experiments to ensure its reliability and accuracy. Finally, the dynamic performance of the test structure is obtained through hammering experiments. The experimental results show that both the linear error and repeatability error of the output are below 1%. The measurement error is less than 0.9%. Class A uncertainty is less than 2.9%. The first natural frequency is 2428Hz. The experiment on normal pressure interference reveals minimal impact on friction measurement results, the error is less than 1.7%. The proposed method enhances the measurement techniques for assessing aircraft surface friction resistance during wind tunnel tests, thereby offering valuable technical support for the advancement of the aerospace industry.
- 21 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 14929-14940
Research on Piezoelectric Sensor for Micro Friction Measurement Based on Torque Amplification
The accurate measurement of surface friction resistance is crucial in the design of hypersonic vehicles, given its significant impact on the overall performance. To fulfill the stringent requirements of high sensitivity and resistance to normal force interference during testing, the present study introduces a novel approach for directly measuring surface micro friction force. This approach utilizes torque amplification principles based on the torsion characteristics of quartz wafer. Firstly, a detailed analysis is conducted to investigate the relationship between sensor stress and the measured force. This examination reveals the governing stress law on the wafer surface. Subsequently, by leveraging the force-to-electric conversion principle of quartz crystal, an accurate charge output model is established for the wafer when subjected to an input force. Simulation analysis is performed to validate the obtained results and to further explore the charge output behavior of the wafer under normal surface pressure. Secondly, the design of the surface friction measurement structure is meticulously carried out. This measurement structure is then subjected to rigorous static calibration and positive pressure interference verification experiments to ensure its reliability and accuracy. Finally, the dynamic performance of the test structure is obtained through hammering experiments. The experimental results show that both the linear error and repeatability error of the output are below 1%. The measurement error is less than 0.9%. Class A uncertainty is less than 2.9%. The first natural frequency is 2428Hz. The experiment on normal pressure interference reveals minimal impact on friction measurement results, the error is less than 1.7%. The proposed method enhances the measurement techniques for assessing aircraft surface friction resistance during wind tunnel tests, thereby offering valuable technical support for the advancement of the aerospace industry.
- 20 November 2022
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (1) , 53-62
Development of the piezoelectric dynamometer for brittle material drilling
When processing deep and small holes in optical glass with a diamond core drill, the cutting force is minimal and very variable. It is challenging to measure the cutting force because of the high cutting frequency and small value of the cutting operation. In this study, a piezoelectric three-component dynamometer with excellent axial sensitivity is developed based on the measuring properties of quartz wafers and characteristics of cutting forces during processing. The dynamometer’s four sensors are positioned vertically, which could increase the dynamometer’s axial sensitivity. The dynamometer’s calibration studies were conducted in both static and dynamic modes. The output consists of the dynamometer was verified using a multi-point loading experiment. According to the experimental findings, the dynamometer’s linearity error and repeatability error are both less than 0.5%. Less than 1.6% and 2.9%, respectively, are found in the output error and crosstalk of multi-point loading experiment. The frequency of nature is higher than 1500 Hz. An experiment measuring cutting force was completed lastly. The findings of the experiment confirm the viability of the dynamometer by demonstrating that it performs well and can identify changes in cutting force caused by two distinct cutting tools when operating under various conditions.
- 20 November 2022
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 46 (1) , 53-62
Development of the piezoelectric dynamometer for brittle material drilling
When processing deep and small holes in optical glass with a diamond core drill, the cutting force is minimal and very variable. It is challenging to measure the cutting force because of the high cutting frequency and small value of the cutting operation. In this study, a piezoelectric three-component dynamometer with excellent axial sensitivity is developed based on the measuring properties of quartz wafers and characteristics of cutting forces during processing. The dynamometer’s four sensors are positioned vertically, which could increase the dynamometer’s axial sensitivity. The dynamometer’s calibration studies were conducted in both static and dynamic modes. The output consists of the dynamometer was verified using a multi-point loading experiment. According to the experimental findings, the dynamometer’s linearity error and repeatability error are both less than 0.5%. Less than 1.6% and 2.9%, respectively, are found in the output error and crosstalk of multi-point loading experiment. The frequency of nature is higher than 1500 Hz. An experiment measuring cutting force was completed lastly. The findings of the experiment confirm the viability of the dynamometer by demonstrating that it performs well and can identify changes in cutting force caused by two distinct cutting tools when operating under various conditions.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (16) , 15893-15902
Development of a Shear-Type Dynamometer for High-Temperature Environment
To improve the accuracy of cutting force measurement and solve the problem of temperature interference in the cutting process, this paper proposes a new four-dimensional force measurement method that uses only y0-type quartz wafers. Firstly, put forward several arrangements of wafers, and establish the output efficiency model of different arrangement schemes. With the goal of maximum output efficiency, determine the optimal arrangement of the wafers. Subsequently, design two kinds of TDTD shear-type piezoelectric sensors, and obtain the performance of the sensor through calibration experiments. The structure of the dynamometer was optimized by using the finite element method. To obtain the lateral output efficiency of the dynamometer, a sensor stiffness measurement experiment was carried out. Finally, static calibration experiments and heat-force calibration experiments were performed on the new dynamometer, and a matrix was established to achieve crosstalk elimination. The experimental results show that the output error and crosstalk of the dynamometer are both < 0.5% at room temperature. The output error is < 1.23 (FS), and the crosstalk is < 3.4% at high temperatures. Compared with the existing research, the new force measurement method proposed in this paper has better accuracy. The new type of dynamometer could provide accurate data for future intelligent manufacturing, and has broad application prospects.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (16) , 15893-15902
Development of a Shear-Type Dynamometer for High-Temperature Environment
To improve the accuracy of cutting force measurement and solve the problem of temperature interference in the cutting process, this paper proposes a new four-dimensional force measurement method that uses only y0-type quartz wafers. Firstly, put forward several arrangements of wafers, and establish the output efficiency model of different arrangement schemes. With the goal of maximum output efficiency, determine the optimal arrangement of the wafers. Subsequently, design two kinds of TDTD shear-type piezoelectric sensors, and obtain the performance of the sensor through calibration experiments. The structure of the dynamometer was optimized by using the finite element method. To obtain the lateral output efficiency of the dynamometer, a sensor stiffness measurement experiment was carried out. Finally, static calibration experiments and heat-force calibration experiments were performed on the new dynamometer, and a matrix was established to achieve crosstalk elimination. The experimental results show that the output error and crosstalk of the dynamometer are both < 0.5% at room temperature. The output error is < 1.23 (FS), and the crosstalk is < 3.4% at high temperatures. Compared with the existing research, the new force measurement method proposed in this paper has better accuracy. The new type of dynamometer could provide accurate data for future intelligent manufacturing, and has broad application prospects.
- 10 October 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 142 (1)
A High-Accuracy Calibration Method Using Sensor Sensitivity Difference for Piezoelectric Dynamometer
High-accuracy measurement of force affects real-time control and process adjustment of industrial production. Piezoelectric sensor can be applied to measure force with the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions. As an important part of test, calibration determines sensitivity coefficient which directly affects test accuracy. To improve the calibration accuracy of offset loading force for multisensor piezoelectric dynamometer, a novel calibration method using sensor sensitivity difference is proposed in this paper. The calibration experiments of four sensors are performed to obtain the axial sensitivities and the force-to-electricity conversion coefficients. The multiple loading-point (MLP) calibration experiments of dynamometer are carried out, and the calibration results prove that the sensitivity difference of four sensors is the main reason affecting the calibration accuracy. The sensitivity difference calibration method (SDCM) is applied to the MLP calibration experiments, and the results show that the average resultant force deviations are reduced from 418.79 N (8.38% full scare (FS) to 24.16 N (0.61% FS) under a loading force of 5000 N, which proves high accuracy and reliability of SDCM. The calibration method will provide guidance for improving the calibration accuracy of dynamometer.
- 10 October 2019
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 142 (1)
A High-Accuracy Calibration Method Using Sensor Sensitivity Difference for Piezoelectric Dynamometer
High-accuracy measurement of force affects real-time control and process adjustment of industrial production. Piezoelectric sensor can be applied to measure force with the characteristics of high frequency and stiffness, great dynamic response and resistance to harsh conditions. As an important part of test, calibration determines sensitivity coefficient which directly affects test accuracy. To improve the calibration accuracy of offset loading force for multisensor piezoelectric dynamometer, a novel calibration method using sensor sensitivity difference is proposed in this paper. The calibration experiments of four sensors are performed to obtain the axial sensitivities and the force-to-electricity conversion coefficients. The multiple loading-point (MLP) calibration experiments of dynamometer are carried out, and the calibration results prove that the sensitivity difference of four sensors is the main reason affecting the calibration accuracy. The sensitivity difference calibration method (SDCM) is applied to the MLP calibration experiments, and the results show that the average resultant force deviations are reduced from 418.79 N (8.38% full scare (FS) to 24.16 N (0.61% FS) under a loading force of 5000 N, which proves high accuracy and reliability of SDCM. The calibration method will provide guidance for improving the calibration accuracy of dynamometer.
- Open Access
- 1 April 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1187 (2) , 022044
Study on Zero Drift of Charge Amplifier Based on MOSFET 3N165 and OPA LF356N
- 1 April 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1187 (2) , 022044
Open AccessStudy on Zero Drift of Charge Amplifier Based on MOSFET 3N165 and OPA LF356N
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (12) , 4723-4735
Thermal Force Uncertainty of Piezoelectric Dynamometer
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (12) , 4723-4735
Thermal Force Uncertainty of Piezoelectric Dynamometer