Kaiji Liao
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kaiji Liao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Zhenyuan Zhang
University of Electronic Science and Technology of China
4 shared publications - Haoyang Fan
School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, Sichuan, China
3 shared publications - Qi Huang
University of Electronic Science and Technology of China
3 shared publications - Arsalan Habib Khawaja
College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, China
2 shared publications - Shi Jing
School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
2 shared publications - Xiaotian Tang
Power System Wide-Area Measurement and Control Sichuan Province Key Laboratory, School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, China
2 shared publications
Latest Publications
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 7941-7951
Application of Magnetoresistive Sensors for Accurate Non-Contact Sag Measurement in Power Transmission Lines
Monitoring the sag of overhead transmission lines under varying environmental and load conditions is essential for ensuring safe operation, adequate ground clearance, and preventing conductor damage. In this study, the application of magnetoresistive sensors to non-contact sag measurement is investigated, and a novel measurement approach is proposed. First, the spatial distribution of the magnetic field and its relationship to conductor sag are examined through numerical integration and finite element simulations, providing recommendations for sensor placement. Next, a new sag measurement method is introduced and validated in multi-conductor setting simulations based on the observed linear relationship between magnetic field intensity along the tower vertical line and conductor sag. Finally, single- and multi-conductor laboratory experiments are conducted, and the results align closely with numerical predictions, demonstrating the feasibility of this approach. A comprehensive signal-to-noise ratio (SNR) analysis confirms that the observed linearity is measurable in real-world conditions. This method offers a reliable and cost-effective solution for overhead transmission line monitoring.
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 7941-7951
Application of Magnetoresistive Sensors for Accurate Non-Contact Sag Measurement in Power Transmission Lines
Monitoring the sag of overhead transmission lines under varying environmental and load conditions is essential for ensuring safe operation, adequate ground clearance, and preventing conductor damage. In this study, the application of magnetoresistive sensors to non-contact sag measurement is investigated, and a novel measurement approach is proposed. First, the spatial distribution of the magnetic field and its relationship to conductor sag are examined through numerical integration and finite element simulations, providing recommendations for sensor placement. Next, a new sag measurement method is introduced and validated in multi-conductor setting simulations based on the observed linear relationship between magnetic field intensity along the tower vertical line and conductor sag. Finally, single- and multi-conductor laboratory experiments are conducted, and the results align closely with numerical predictions, demonstrating the feasibility of this approach. A comprehensive signal-to-noise ratio (SNR) analysis confirms that the observed linearity is measurable in real-world conditions. This method offers a reliable and cost-effective solution for overhead transmission line monitoring.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Frequency-Aided Extended Kalman Filter for Non-Contact Spatial Position Measurement of Overhead Power Lines Using Magnetic Sensors
Accurate spatial position measurement of overhead power lines is essential for ensuring the reliability of power systems, especially in smart grid scenarios that require real-time monitoring. However, existing methods face significant challenges: contact-based techniques, such as tension or differential GPS (DGPS) sensors, are costly and cumbersome, while image-based methods are vulnerable to weather conditions. Magnetic sensors, offering a non-contact measurement approach, present a promising alternative. However, current technology often suffers from non-linearity and high uncertainty in alternating current (AC) environments, limiting their accuracy. This paper introduces a Frequency-Aided Extended Kalman Filter (FA-EKF) algorithm that integrates frequency information into the prediction model, thereby enhancing stability and efficiency in AC signal measurements. The proposed algorithm significantly reduces convergence time and measurement uncertainty. Experimental validation in laboratory-scale models demonstrates the method’s effectiveness, with a relative error of less than 2%. Further simulations show that the method achieves 97.5% relative accuracy at a 2.5-meter distance in one-dimensional measurements and maintains over 90% relative accuracy in two-dimensional measurements within a 1.5-meter radius around the target line in realistic scenarios. This paper also explores the impact of factors such as sensor spacing, angular deviation, and interference from other current sources.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Frequency-Aided Extended Kalman Filter for Non-Contact Spatial Position Measurement of Overhead Power Lines Using Magnetic Sensors
Accurate spatial position measurement of overhead power lines is essential for ensuring the reliability of power systems, especially in smart grid scenarios that require real-time monitoring. However, existing methods face significant challenges: contact-based techniques, such as tension or differential GPS (DGPS) sensors, are costly and cumbersome, while image-based methods are vulnerable to weather conditions. Magnetic sensors, offering a non-contact measurement approach, present a promising alternative. However, current technology often suffers from non-linearity and high uncertainty in alternating current (AC) environments, limiting their accuracy. This paper introduces a Frequency-Aided Extended Kalman Filter (FA-EKF) algorithm that integrates frequency information into the prediction model, thereby enhancing stability and efficiency in AC signal measurements. The proposed algorithm significantly reduces convergence time and measurement uncertainty. Experimental validation in laboratory-scale models demonstrates the method’s effectiveness, with a relative error of less than 2%. Further simulations show that the method achieves 97.5% relative accuracy at a 2.5-meter distance in one-dimensional measurements and maintains over 90% relative accuracy in two-dimensional measurements within a 1.5-meter radius around the target line in realistic scenarios. This paper also explores the impact of factors such as sensor spacing, angular deviation, and interference from other current sources.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2480-2490
Dynamic Impedance and Chaotic Behavior Modeling Featured Novel Robust Arc Fault Identification Approach
Accurate and reliable electric arc fault identification ensures the safety of personnel and equipment through in-field operations and maintenance work. However, due to the application scenarios and nonlinear arc dynamics, the distortion degree of the detectable signals is influenced by network/circuit structure, system parameter, operation manner, etc., the salience of the fault signatures may change significantly, which poses challenges to develop the “generic scheme” in arc faults identification. To address such issues, this paper proposed a robustness-improved arc fault identification approach that incorporates the modeling of dynamic impedance and chaotic behavior in faulting systems. For describing the “unique” nonlinear characteristics of arc faults among different operation scenarios, the HT-based dynamic impedance (HTDI) representation method is developed to extract the “signatures” of arc faults, and the mechanism of how system parameters impact the presentation form of arc fault features are also revealed. Meanwhile, for quantitively extracting the signatures, the chaotic behavior of arcing fault system has been analyzed in phase space in detail, with a series of chaos indicators. Additionally, HTDI and chaos indicators implemented LSTM classifier has been designed to achieve accurate and rapid arcing fault identification with time-series inputs. With the series of actual arc fault cases and simulation cases under different configurations, the effectiveness and robustness of the proposed method have been thoroughly validated.
- 6 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (2) , 2480-2490
Dynamic Impedance and Chaotic Behavior Modeling Featured Novel Robust Arc Fault Identification Approach
Accurate and reliable electric arc fault identification ensures the safety of personnel and equipment through in-field operations and maintenance work. However, due to the application scenarios and nonlinear arc dynamics, the distortion degree of the detectable signals is influenced by network/circuit structure, system parameter, operation manner, etc., the salience of the fault signatures may change significantly, which poses challenges to develop the “generic scheme” in arc faults identification. To address such issues, this paper proposed a robustness-improved arc fault identification approach that incorporates the modeling of dynamic impedance and chaotic behavior in faulting systems. For describing the “unique” nonlinear characteristics of arc faults among different operation scenarios, the HT-based dynamic impedance (HTDI) representation method is developed to extract the “signatures” of arc faults, and the mechanism of how system parameters impact the presentation form of arc fault features are also revealed. Meanwhile, for quantitively extracting the signatures, the chaotic behavior of arcing fault system has been analyzed in phase space in detail, with a series of chaos indicators. Additionally, HTDI and chaos indicators implemented LSTM classifier has been designed to achieve accurate and rapid arcing fault identification with time-series inputs. With the series of actual arc fault cases and simulation cases under different configurations, the effectiveness and robustness of the proposed method have been thoroughly validated.
- Open Access
- 7 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2159
High-Precision Wafer Bonding Alignment Mark Using Moiré Fringes and Digital Grating
This paper investigates a moiré-based mark for high-precision wafer bonding alignment. During alignment, the mark is combined with digital grating, which has the benefits of high precision and small size. A digital grating is superimposed on the mark to generate moiré fringes. By performing a phase calculation on the moiré fringe images corresponding to the upper and lower wafers, the relative offset of the upper and lower wafers can be accurately calculated. These moiré fringes are exceptionally stable, thereby enhancing the alignment stability. In this study, through practical experiments, we tested the rationality and practicability of the mark.
- 7 December 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (12) , 2159
Open AccessHigh-Precision Wafer Bonding Alignment Mark Using Moiré Fringes and Digital Grating
This paper investigates a moiré-based mark for high-precision wafer bonding alignment. During alignment, the mark is combined with digital grating, which has the benefits of high precision and small size. A digital grating is superimposed on the mark to generate moiré fringes. By performing a phase calculation on the moiré fringe images corresponding to the upper and lower wafers, the relative offset of the upper and lower wafers can be accurately calculated. These moiré fringes are exceptionally stable, thereby enhancing the alignment stability. In this study, through practical experiments, we tested the rationality and practicability of the mark.
- 18 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1518-1524
A Novel Non-contact Measurement Method for Current Positioning Based on Magnetic Sensors
With the intelligent and distributed development of the power grid, the demand for the security of power systems is increasing. As an essential part of energy transportation in power systems, transmission lines have arc sags and wind-induced swings that can lead to serious safety incidents, so more and more researchers are studying the spatial condition monitoring of transmission lines. The existing methods usually use intrusive sensors, such as temperature sensors, or need photographic image analysis. Nevertheless, the intrusive sensors may increase safety risk, and the image analysis can be affected by extreme weather conditions. This paper proposes a novel non-contact method for current measurement and spatial positioning based on magnetic field sensors. In this method, two sensors are combined as a probe. By analyzing the magnetic field at different distances, the space position of the conductor and the target current can be calculated. Since the measurement results of this method are unstable when the target current is close to 0, this paper proposes an optimized method by using a limiter and digital low-pass filter to process the distance values, which effectively improves the measurement stability and accuracy. In experiments, the average error of distance is about 1%, and the error of the current RMS is about 2%.
- 18 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1518-1524
A Novel Non-contact Measurement Method for Current Positioning Based on Magnetic Sensors
With the intelligent and distributed development of the power grid, the demand for the security of power systems is increasing. As an essential part of energy transportation in power systems, transmission lines have arc sags and wind-induced swings that can lead to serious safety incidents, so more and more researchers are studying the spatial condition monitoring of transmission lines. The existing methods usually use intrusive sensors, such as temperature sensors, or need photographic image analysis. Nevertheless, the intrusive sensors may increase safety risk, and the image analysis can be affected by extreme weather conditions. This paper proposes a novel non-contact method for current measurement and spatial positioning based on magnetic field sensors. In this method, two sensors are combined as a probe. By analyzing the magnetic field at different distances, the space position of the conductor and the target current can be calculated. Since the measurement results of this method are unstable when the target current is close to 0, this paper proposes an optimized method by using a limiter and digital low-pass filter to process the distance values, which effectively improves the measurement stability and accuracy. In experiments, the average error of distance is about 1%, and the error of the current RMS is about 2%.