Paul Maria Scheikl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Maria Scheikl has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Franziska Mathis-Ullrich
Dep. Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen , Germany
6 shared publications - Axel Krieger
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, USA
4 shared publications - Anton Deguet
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA
3 shared publications - Martin Wagner
Department of Visceral, Thoracic and Vascular Surgery, Faculty of Medicine, University Hospital Carl Gustav Carus, Dresden, Germany
3 shared publications - Pit Henrich
Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-University Erlangen-Nrnberg, Erlangen, Germany
3 shared publications - Alan Kuntz
Robotics Center and the Kahlert School of Computing, University of Utah, Salt Lake City, UT, USA
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- p. 1-20
Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- p. 1-20
Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 8 (1) , 188-197
Integrating Learned Retraction and Model-Based Resection Planning for Automated Central Airway Obstruction Removal
Surgeon shortages have driven significant recent advances in robotic surgical assistance. To progress toward surgical automation, we address transoral central airway obstruction (CAO) removal, selecting this procedure for its relatively constrained environment and clear clinical objectives. Prior work has demonstrated successful CAO removal with single-port, minimally invasive robotic systems, making it a promising target for autonomy. We present a new autonomous system designed for CAO removal that integrates a learning-based tissue retraction policy with a model-based resection planner, deployed on a bimanual robotic platform with vision guidance. While our long-term motivation is minimally invasive intervention, we evaluate our approach in an open-surgery setting, enabling rapid development and testing. We evaluate our system in 12 ex vivo CAO removal procedures running at three distinct levels of autonomy. Our results indicate that the learned retraction policy performs similarly or better than a manually designed heuristic, with a mean surgeon-rated score (1-10) of 8.0± 1.6 compared to 6.8± 2.5, and a mean percent tumor volume removal of 113.9± 18.8% compared to 111.9± 13.3%. The model-based resections performed best when supervised, resulting in less tissue damage and better cutting accuracy. Furthermore, our approach produced clinically successful outcomes in all eight supervised autonomous trials. Notably, in one case, the system achieved complete tumor removal without any human intervention. Our overall findings underscore the importance of high-level supervision, revealing targets for future automation.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- 14 July 2025
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 10 (03n04)
Autonomous Vision-Guided Resection of Central Airway Obstruction
Existing tracheal tumor resection methods often lack the precision required for effective airway clearance, and robotic advancements offer new potential for autonomous resection. We present a vision-guided, autonomous approach for palliative resection of tracheal tumors. This system models the tracheal surface with a fifth-degree polynomial to plan tool trajectories, while a custom Faster R-CNN segmentation pipeline identifies the trachea and tumor boundaries. The electrocautery tool angle is optimized using handheld surgical demonstrations, and trajectories are planned to maintain a 1[ ]mm safety clearance from the tracheal surface. We validated the workflow successfully in five consecutive experiments on ex-vivo animal tissue models, successfully clearing the airway obstruction without trachea perforation in all cases (with more than 90% volumetric tumor removal). These results support the feasibility of an autonomous resection platform, paving the way for future developments in minimally-invasive autonomous resection.
- Top Cited Papers
- 9 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (104) , eadt5254
SRT-H: A hierarchical framework for autonomous surgery via language-conditioned imitation learning
Research on autonomous surgery has largely focused on simple task automation in controlled environments. However, real-world surgical applications demand dexterous manipulation over extended durations and robust generalization to the inherent variability of human tissue. These challenges remain difficult to address using existing logic-based or conventional end-to-end learning strategies. To address this gap, we propose a hierarchical framework for performing dexterous, long-horizon surgical steps. Our approach uses a high-level policy for task planning and a low-level policy for generating low-level trajectories. The high-level planner plans in language space, generating task-level or corrective instructions that guide the robot through the long-horizon steps and help recover from errors made by the low-level policy. We validated our framework through ex vivo experiments on cholecystectomy, a commonly practiced minimally invasive procedure, and conducted ablation studies to evaluate key components of the system. Our method achieves a 100% success rate across eight different ex vivo gallbladders, operating fully autonomously without human intervention. The hierarchical approach improved the policy’s ability to recover from suboptimal states that are inevitable in the highly dynamic environment of realistic surgical applications. This work demonstrates step-level autonomy in a surgical procedure, marking a milestone toward clinical deployment of autonomous surgical systems.
- 9 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (104) , eadt5254
Top Cited PapersSRT-H: A hierarchical framework for autonomous surgery via language-conditioned imitation learning
Research on autonomous surgery has largely focused on simple task automation in controlled environments. However, real-world surgical applications demand dexterous manipulation over extended durations and robust generalization to the inherent variability of human tissue. These challenges remain difficult to address using existing logic-based or conventional end-to-end learning strategies. To address this gap, we propose a hierarchical framework for performing dexterous, long-horizon surgical steps. Our approach uses a high-level policy for task planning and a low-level policy for generating low-level trajectories. The high-level planner plans in language space, generating task-level or corrective instructions that guide the robot through the long-horizon steps and help recover from errors made by the low-level policy. We validated our framework through ex vivo experiments on cholecystectomy, a commonly practiced minimally invasive procedure, and conducted ablation studies to evaluate key components of the system. Our method achieves a 100% success rate across eight different ex vivo gallbladders, operating fully autonomously without human intervention. The hierarchical approach improved the policy’s ability to recover from suboptimal states that are inevitable in the highly dynamic environment of realistic surgical applications. This work demonstrates step-level autonomy in a surgical procedure, marking a milestone toward clinical deployment of autonomous surgical systems.
- 2 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (8) , 8522-8529
Point Cloud Segmentation for Autonomous Clip Positioning in Laparoscopic Cholecystectomy on a Phantom
High-risk applications in robotics, such as robot-assisted surgery, present unique challenges. These systems must be both highly precise and interpretable in order to be deployed in environments with very low tolerance for error or unsafe exploration. We present the first robotic system to demonstrate autonomous clip positioning on a physical phantom in laparoscopic surgery, one of the most common interventions in general surgery. After segmentation of a colorless point cloud from a single camera, target positions for the clips are extracted using spline interpolation, and can then be adjusted by the human operator. The segmentation model is trained on only 60 hand-labeled real point clouds, reflecting data scarcity in the surgical domain. We overcome this with a combination of pre-training on 128,000 synthetic point clouds and two novel data augmentation techniques. The motion of the end-effector to each target is visualized for the operator, satisfying the unique motion constraints of minimally-invasive surgery while ensuring that the robot's actions are verifiable and interpretable. In real robot experiments, our system localizes targets with the required precision of 0.75 mm at a 95% success rate and executes autonomous clip positioning with a 100% success rate. We provide insights that are applicable to many other surgical and non-surgical tasks that require identifying and navigating to a precise target. Our source code is available at https://github.com/balazsgyenes/kirurc
- 2 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (8) , 8522-8529
Point Cloud Segmentation for Autonomous Clip Positioning in Laparoscopic Cholecystectomy on a Phantom
High-risk applications in robotics, such as robot-assisted surgery, present unique challenges. These systems must be both highly precise and interpretable in order to be deployed in environments with very low tolerance for error or unsafe exploration. We present the first robotic system to demonstrate autonomous clip positioning on a physical phantom in laparoscopic surgery, one of the most common interventions in general surgery. After segmentation of a colorless point cloud from a single camera, target positions for the clips are extracted using spline interpolation, and can then be adjusted by the human operator. The segmentation model is trained on only 60 hand-labeled real point clouds, reflecting data scarcity in the surgical domain. We overcome this with a combination of pre-training on 128,000 synthetic point clouds and two novel data augmentation techniques. The motion of the end-effector to each target is visualized for the operator, satisfying the unique motion constraints of minimally-invasive surgery while ensuring that the robot's actions are verifiable and interpretable. In real robot experiments, our system localizes targets with the required precision of 0.75 mm at a 95% success rate and executes autonomous clip positioning with a 100% success rate. We provide insights that are applicable to many other surgical and non-surgical tasks that require identifying and navigating to a precise target. Our source code is available at https://github.com/balazsgyenes/kirurc
- 24 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4283-4299
LUDO: Low-Latency Understanding of Deformable Objects Using Point Cloud Occupancy Functions
Accurately determining the shape of deformable objects and the location of their internal structures is crucial for medical tasks that require precise targeting, such as robotic biopsies. We introduce LUDO, a method for accurate low-latency understanding of deformable objects. LUDO reconstructs objects in their deformed state, including their internal structures, from a single-view point cloud observation in under 30 ms using occupancy networks. LUDO provides uncertainty estimates for its predictions. Additionally, it provides explainability by highlighting key features in its input observations. Both uncertainty and explainability are important for safety-critical applications such as surgery. We evaluate LUDO in real-world robotic experiments, achieving a success rate of 98.9% for puncturing various regions of interest (ROIs) inside deformable objects. We compare LUDO to a popular baseline and show its superior ROI localization accuracy, training time, and memory requirements. LUDO demonstrates the potential to interact with deformable objects without the need for deformable registration methods.
- 24 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 41 (15523098) , 4283-4299
LUDO: Low-Latency Understanding of Deformable Objects Using Point Cloud Occupancy Functions
Accurately determining the shape of deformable objects and the location of their internal structures is crucial for medical tasks that require precise targeting, such as robotic biopsies. We introduce LUDO, a method for accurate low-latency understanding of deformable objects. LUDO reconstructs objects in their deformed state, including their internal structures, from a single-view point cloud observation in under 30 ms using occupancy networks. LUDO provides uncertainty estimates for its predictions. Additionally, it provides explainability by highlighting key features in its input observations. Both uncertainty and explainability are important for safety-critical applications such as surgery. We evaluate LUDO in real-world robotic experiments, achieving a success rate of 98.9% for puncturing various regions of interest (ROIs) inside deformable objects. We compare LUDO to a popular baseline and show its superior ROI localization accuracy, training time, and memory requirements. LUDO demonstrates the potential to interact with deformable objects without the need for deformable registration methods.
- 27 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (6) , 5338-5345
Movement Primitive Diffusion: Learning Gentle Robotic Manipulation of Deformable Objects
Policy learning in robot-assisted surgery (RAS) lacks data efficient and versatile methods that exhibit the desired motion quality for delicate surgical interventions. To this end, we introduce Movement Primitive Diffusion (MPD), a novel method for imitation learning (IL) in RAS that focuses on gentle manipulation of deformable objects. The approach combines the versatility of diffusion-based imitation learning (DIL) with the high-quality motion generation capabilities of Probabilistic Dynamic Movement Primitives (ProDMPs). This combination enables MPD to achieve gentle manipulation of deformable objects, while maintaining data efficiency critical for RAS applications where demonstration data is scarce. We evaluate MPD across various simulated and real world robotic tasks on both state and image observations. MPD outperforms state-of-the-art DIL methods in success rate, motion quality, and data efficiency.
- 27 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (6) , 5338-5345
Movement Primitive Diffusion: Learning Gentle Robotic Manipulation of Deformable Objects
Policy learning in robot-assisted surgery (RAS) lacks data efficient and versatile methods that exhibit the desired motion quality for delicate surgical interventions. To this end, we introduce Movement Primitive Diffusion (MPD), a novel method for imitation learning (IL) in RAS that focuses on gentle manipulation of deformable objects. The approach combines the versatility of diffusion-based imitation learning (DIL) with the high-quality motion generation capabilities of Probabilistic Dynamic Movement Primitives (ProDMPs). This combination enables MPD to achieve gentle manipulation of deformable objects, while maintaining data efficiency critical for RAS applications where demonstration data is scarce. We evaluate MPD across various simulated and real world robotic tasks on both state and image observations. MPD outperforms state-of-the-art DIL methods in success rate, motion quality, and data efficiency.
- 8 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (2) , 560-567
Sim-to-Real Transfer for Visual Reinforcement Learning of Deformable Object Manipulation for Robot-Assisted Surgery
Automation holds the potential to assist surgeons in robotic interventions, shifting their mental work load from visuomotor control to high level decision making. Reinforcement learning has shown promising results in learning complex visuomotor policies, especially in simulation environments where many samples can be collected at low cost. A core challenge is learning policies in simulation that can be deployed in the real world, thereby overcoming the sim-to-real gap. In this letter, we bridge the visual sim-to-real gap with an image-based reinforcement learning pipeline based on pixel-level domain adaptation and demonstrate its effectiveness on an image-based task in deformable object manipulation. We choose a tissue retraction task because of its importance in clinical reality of precise cancer surgery. After training in simulation on domain-translated images, our policy requires no retraining to perform tissue retraction with a 50% success rate on the real robotic system using raw RGB images. Furthermore, our sim-to-real transfer method makes no assumptions on the task itself and requires no paired images. This letter introduces the first successful application of visual sim-to-real transfer for robotic manipulation of deformable objects in the surgical field, which represents a notable step towards the clinical translation of cognitive surgical robotics.
- 8 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (2) , 560-567
Sim-to-Real Transfer for Visual Reinforcement Learning of Deformable Object Manipulation for Robot-Assisted Surgery
Automation holds the potential to assist surgeons in robotic interventions, shifting their mental work load from visuomotor control to high level decision making. Reinforcement learning has shown promising results in learning complex visuomotor policies, especially in simulation environments where many samples can be collected at low cost. A core challenge is learning policies in simulation that can be deployed in the real world, thereby overcoming the sim-to-real gap. In this letter, we bridge the visual sim-to-real gap with an image-based reinforcement learning pipeline based on pixel-level domain adaptation and demonstrate its effectiveness on an image-based task in deformable object manipulation. We choose a tissue retraction task because of its importance in clinical reality of precise cancer surgery. After training in simulation on domain-translated images, our policy requires no retraining to perform tissue retraction with a 50% success rate on the real robotic system using raw RGB images. Furthermore, our sim-to-real transfer method makes no assumptions on the task itself and requires no paired images. This letter introduces the first successful application of visual sim-to-real transfer for robotic manipulation of deformable objects in the surgical field, which represents a notable step towards the clinical translation of cognitive surgical robotics.
- Open Access
- 1 August 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (1) , 87-91
Flexible Facile Tactile Sensor for Smart Vessel Phantoms
Smart medical phantoms for training and evaluation of endovascular procedures ought to measure impact forces on the vessel walls worth protecting to provide feedback to clinicians and articulated soft robots. Recent commercial smart phantoms are expensive, usually not customizable to different applications and lack accessibility for integrated development. This work investigates piezoresistive films as highly integratable flexible sensors to be used in arbitrary soft vessel phantom anatomies over large surfaces and curved shapes providing quantitative measurement in the force range up to 1 N with 0.1 N resolution. First results show promising performance at the point of calibration and in a 5 mm range around it, with absolute measuring error of 28 mN and a standard deviation of ±10 mN and response times <500 ms. Future work shall address the optimization of response time and sensor shapes as well as the evaluation with experienced clinicians.
- 1 August 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (1) , 87-91
Open AccessFlexible Facile Tactile Sensor for Smart Vessel Phantoms
Smart medical phantoms for training and evaluation of endovascular procedures ought to measure impact forces on the vessel walls worth protecting to provide feedback to clinicians and articulated soft robots. Recent commercial smart phantoms are expensive, usually not customizable to different applications and lack accessibility for integrated development. This work investigates piezoresistive films as highly integratable flexible sensors to be used in arbitrary soft vessel phantom anatomies over large surfaces and curved shapes providing quantitative measurement in the force range up to 1 N with 0.1 N resolution. First results show promising performance at the point of calibration and in a 5 mm range around it, with absolute measuring error of 28 mN and a standard deviation of ±10 mN and response times <500 ms. Future work shall address the optimization of response time and sensor shapes as well as the evaluation with experienced clinicians.