PDPijush Kanti Dhara

Pijush Kanti Dhara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pijush Kanti Dhara has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Estimation of Minimum Inertia and Fast Frequency Support for Renewable Energy Dominated Power Systems

    by Pijush Kanti Dhara, Zakir Hussain Rather, Chitaranjan Phurailatpam

    Displacement of conventional generations with the rapid adoption of renewable energy (RE) sources has led to diminishing system inertia and active power reserves. Consequently, power systems with high shares of RE sources have become more susceptible to frequency stability issues, often experiencing higher rate of change of frequency (RoCoF) and frequency deviations. Accurate estimation of essential system services required to maintain a stable and economic operation has become crucial. This paper proposes a new method for the accurate estimation of minimum synchronous inertia and frequency containment reserve (FCR) response to ensure compliance with system-specified RoCoF and frequency deviation limits. Firstly, the minimum synchronous inertia requirement for a specified RoCoF limit is calculated, which also considers the instantaneous response from demand, Type-I and Type-II wind generators, that are generally difficult to monitor. The overall FCR requirement is then estimated to maintain the frequency deviation within the pre-defined limits. Dynamic FCR response includes fast frequency response (FFR) from inverter-based resources (IBR), responses from load and governors from conventional generations. Finally, the share of FFR contribution coming from IBRs, representing the system service requirement, is segregated from the overall FCR and estimated accurately. With the proposed method, system operators can be best informed of the exact minimum inertia and FFR requirement to ensure frequency stability. The proposed methodology is tested and validated in a modified IEEE 39-bus system and an actual grid model of the Gujarat State in India.


  • A Novel Approach to Determine and Maintain Area-Wise Minimum Inertia in Renewable Energy Dominated Power Systems

    by Pijush Kanti Dhara, Zakir Hussain Rather

    The rapid displacement of synchronous generators by increased penetration of inverter-based resources (IBR) in power system areas that are potentially rich in renewable energy can lead to spatial non-uniform distribution of synchronous inertia. Consequently, even if the overall minimum inertia (MI) of the system is maintained, certain areas may experience stability issues, which would breach grid-code limits for the rate of change of frequency (RoCoF) following a contingency. Given this context, a method to determine the MI that is specific to individual areas is introduced. Additionally, a method for redistributing surplus inertia from high-inertia areas to low inertia areas is introduced by reducing electrical distance between the nodes. This approach utilizes green corridors, which are additional transmission lines that are established to evacuate surplus renewable power to the areas with higher demand and fossil-fueled-based generation, as pathways to transfer inertia. Furthermore, a machine-learning-assisted technique to compensate for shortfall in area-wise MI by placing new synchronous inertia compensators is proposed. Using this method, system operators can identify the location and size of synchronous or virtual inertia that may be required. The amount of additionally required inertia is quantified by the size of synchronous inertia compensators, to uphold area-specific RoCoF in renewable energy-integrated power systems. The proposed methodology is tested and validated in the modified IEEE-39 bus system.


  • Non-synchronous Inertia Estimation in a Renewable Energy Integrated Power System With Reduced Number of Monitoring Nodes

    by Pijush Kanti Dhara, Zakir Hussain Rather

    Accurate estimation of non-synchronous inertia in renewable energy (RE)-integrated power systems is challenging through conventional approaches, as emulated inertia from inverter-based resources (IBRs) is fundamentally different from the inherent inertial response of synchronous generators. In this context, this paper presents a novel realistic approach for estimating the non-synchronous inertial response in a large-scale RE-integrated power system. The method incorporates an optimal number of frequency and voltage monitoring nodes while ensuring an accurate estimation of non-synchronous inertia. In the proposed method, the synchronous inertial response for a frequency disturbance is estimated first using the conventional approach, followed by an estimate of the loads’ inertial contribution. The latter is calculated using center-of-inertia frequency and voltage measurement across the power system with a voltage-controlled zone approach. Finally, the non-synchronous inertial response is estimated by segregating the aggregate inertial response of synchronous generators and the loads from the overall estimated inertia of the system. The proposed approach can help the system operator determine inertial contributions from the loads and IBRs depending on loading conditions and the availability of virtual inertia from RE sources, estimate the minimum required synchronous inertia, and select the appropriate proportional gains and time constants of virtual inertial controllers. The proposed method is validated by implementing it on a modified IEEE 39-bus system and a real-life Gujarat State grid model (in India).