Chang-Sik John Pak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chang-Sik John Pak has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Eunju Lee
Cybernetics Lab, Department of Plastic Surgery, Biomedical Engineering Research Center, Seoul Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
1 shared publication - Gyubeom Lim
Department of Plasma Bio Display, Kwangwoon University, Seoul 01897, Republic of Korea
1 shared publication - Hak Yi
Department of Mechanical Engineering, Kyungpook National University, Daegu, Korea
1 shared publication - Hoijun Kim
Department of Plasma Bio Display, Kwangwoon University, Seoul 01897, Republic of Korea
1 shared publication - Hyojin Kim
Cybernetics Lab, Department of Plastic Surgery, Biomedical Engineering Research Center, Seoul Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
1 shared publication - Hyung Hwa Jeong
Department of Plastic and Reconstructive Surgery, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon, Korea
1 shared publication
Latest Publications
- 12 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (3) , 1163-1181
Development of Variable-Stiffness Knee Prosthesis with Agonist-Antagonist Mechanism for Lower-Limb Amputees
- 12 January 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (3) , 1163-1181
Development of Variable-Stiffness Knee Prosthesis with Agonist-Antagonist Mechanism for Lower-Limb Amputees
- Open Access
- 9 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12659
Implementation of the XR Rehabilitation Simulation System for the Utilization of Rehabilitation with Robotic Prosthetic Leg
With the recent development of a digital rehabilitation system, research on the rehabilitation of amputees is accelerating. However, research on rehabilitation systems for patients with amputation of the lower extremities is insufficient. For the rehabilitation of amputees, it is important to maintain muscle mass through the improvement of muscle movement memory, continuous rehabilitation learning, and motivation to improve efficiency. The rehabilitation system in a virtual environment is convenient in that there is no restriction on time and space because rehabilitation training of amputees is possible without removing/attaching general prosthetic legs and robot prosthetic legs. In this paper, we propose an XR rehabilitation system for patients with lower extremity amputation to improve the motivational aspect of rehabilitation training. The proposed method is a system that allows patients and clinical experts to perform rehabilitation in the same environment using two XR equipment called HoloLens 2. The content was provided in the form of a game in which the number of movements of amputees was allocated as scores to enhance rehabilitation convenience and motivation aspects. The virtual 3D model prosthetic leg used in-game content worked through the acquisition and processing of the patient’s actual muscle EMG (ElectroMyoGraphy) signal. In order to improve reactivity, there was a time limit for completing the operation. The classified action should be completed by the amputee within the time limit, although the number of times set as the target. To complete the operation, the amputee must force the amputation area to exceed an arbitrarily set threshold. The evaluation results were evaluated through an independent sample t-test. we contribute to the development of digital rehabilitation simulation systems. XR rehabilitation training techniques, operated with EMG signals obtained from actual amputation sites, contribute to the promotion of rehabilitation content in patients with amputation of the lower extremities. It is expected that this paper will improve the convenience and rehabilitation of rehabilitation training in the future.
- 9 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12659
Open AccessImplementation of the XR Rehabilitation Simulation System for the Utilization of Rehabilitation with Robotic Prosthetic Leg
With the recent development of a digital rehabilitation system, research on the rehabilitation of amputees is accelerating. However, research on rehabilitation systems for patients with amputation of the lower extremities is insufficient. For the rehabilitation of amputees, it is important to maintain muscle mass through the improvement of muscle movement memory, continuous rehabilitation learning, and motivation to improve efficiency. The rehabilitation system in a virtual environment is convenient in that there is no restriction on time and space because rehabilitation training of amputees is possible without removing/attaching general prosthetic legs and robot prosthetic legs. In this paper, we propose an XR rehabilitation system for patients with lower extremity amputation to improve the motivational aspect of rehabilitation training. The proposed method is a system that allows patients and clinical experts to perform rehabilitation in the same environment using two XR equipment called HoloLens 2. The content was provided in the form of a game in which the number of movements of amputees was allocated as scores to enhance rehabilitation convenience and motivation aspects. The virtual 3D model prosthetic leg used in-game content worked through the acquisition and processing of the patient’s actual muscle EMG (ElectroMyoGraphy) signal. In order to improve reactivity, there was a time limit for completing the operation. The classified action should be completed by the amputee within the time limit, although the number of times set as the target. To complete the operation, the amputee must force the amputation area to exceed an arbitrarily set threshold. The evaluation results were evaluated through an independent sample t-test. we contribute to the development of digital rehabilitation simulation systems. XR rehabilitation training techniques, operated with EMG signals obtained from actual amputation sites, contribute to the promotion of rehabilitation content in patients with amputation of the lower extremities. It is expected that this paper will improve the convenience and rehabilitation of rehabilitation training in the future.