Temitope F. Adeyemi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Temitope F. Adeyemi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Stephen Kenji Aoki
Department of Orthopaedics University of Utah Salt Lake City Utah U.S.A.
3 shared publications - Travis G. Maak
Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
3 shared publications - Andrew R. Stephens
Department of Physical Medicine and Rehabilitation, University of Rochester Medical Center, Rochester, NY, United States
1 shared publication Cody McGrale
University of Utah
1 shared publication- Lindsey L. Reader
University of Utah
1 shared publication Mark E. Ms Beese
M. R. Karns, T. F. Adeyemi, S. K. Aoki, M. E. Beese, T. G. Maak, Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT, USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Paper 13: Traction Application Method Influences Force and Distraction Parameters at Venting and Capsulotomy
Objectives: This study examined the effects of traction application method – either a standard peroneal post or a postless method -- on traction and distraction variables before and after venting and capsulotomy. A more robust understanding of the direct effects of each intervention under different traction conditions may inform clinical decisions about compartment access and/or methods of traction application. Methods: Fluoroscopic images were taken before and after traction application, venting, and capsulotomy in primary hip arthroscopies by a single surgeon; these were used to measure distraction distances, which were each normalized to the diameter of the femoral head in the same image to account for the effect any purely positional differences across time points. Traction forces were also recorded at traction application, before/after venting, and before/after capsulotomy. Traction method, as well as sex and hamstring flexibility scores (known to influence degree of distraction) were assessed via standard least squares models for their effects on: 1) Instantaneous traction forces before venting, after venting, before capsulotomy, and after capsulotomy 2) Distraction differences -- expressed as % femoral head diameter -- between the neutral state and the values at these same interventions 3) The ratios of normalized distraction differences to traction forces at each intervention Results: Both initial distraction and after-venting distraction values differed significantly with respect to sex (distraction: p<0.0001, venting: p<0.0001 ), and hamstring flexibility (distraction: p<0.0140, venting: p<0.0040), with larger distraction magnitudes in female and more flexible patients. After-capsulotomy distraction differed with sex (p<0.0001) and traction method (p<0.0056), with female and peroneal post-distracted patients exhibiting higher distraction magnitudes. All force values along the intervention trajectory (before and after venting, before and after capsulotomy) differed with respect to sex and traction method, but not with hamstring flexibility (Table1). Male patients and post-distracted patients exhibited higher forces. Distraction-traction ratios (distraction achieved per unit force applied) differed with respect to sex, traction method, and hamstring flexibility at all interventions – except for the after-capsulotomy ratio, which was unaffected by hamstring flexibility (Table 1). Higher values (more distraction achieved per unit force) were seen in more flexible patients, female patients, and patients distracted via the postless method. The differences between ratios before and after an intervention differed with respect to sex for venting (p<0.0106), and both sex and traction method for capsulotomy (sex: p<0.0001 traction: p<0.0379), representing more distraction achieved per unit force after capsulotomy in the post-distracted group, and for female patients at both interventions. Conclusions: The distraction results indicate that the posted and postless methods of traction application do not differ significantly in the magnitude of distraction achieved (except after capsulotomy), but depend more on patient flexibility. The fact that after-capsulotomy distractions are larger in the post-distracted group may point to differences in soft tissue strain patterns between traction application methods. Traction forces are higher in post-distracted group but yield lower distraction distances per unit force than the postless method overall; the exception to this pattern is the ratio taken after capsulotomy, which is higher in the post-distracted group. Taken together, these results may support a switch to postless methods and invite further investigation into the anatomical and mechanical patterns governing capsular integrity.
- 1 July 2023
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 11 (7_suppl3)
Open AccessPaper 13: Traction Application Method Influences Force and Distraction Parameters at Venting and Capsulotomy
Objectives: This study examined the effects of traction application method – either a standard peroneal post or a postless method -- on traction and distraction variables before and after venting and capsulotomy. A more robust understanding of the direct effects of each intervention under different traction conditions may inform clinical decisions about compartment access and/or methods of traction application. Methods: Fluoroscopic images were taken before and after traction application, venting, and capsulotomy in primary hip arthroscopies by a single surgeon; these were used to measure distraction distances, which were each normalized to the diameter of the femoral head in the same image to account for the effect any purely positional differences across time points. Traction forces were also recorded at traction application, before/after venting, and before/after capsulotomy. Traction method, as well as sex and hamstring flexibility scores (known to influence degree of distraction) were assessed via standard least squares models for their effects on: 1) Instantaneous traction forces before venting, after venting, before capsulotomy, and after capsulotomy 2) Distraction differences -- expressed as % femoral head diameter -- between the neutral state and the values at these same interventions 3) The ratios of normalized distraction differences to traction forces at each intervention Results: Both initial distraction and after-venting distraction values differed significantly with respect to sex (distraction: p<0.0001, venting: p<0.0001 ), and hamstring flexibility (distraction: p<0.0140, venting: p<0.0040), with larger distraction magnitudes in female and more flexible patients. After-capsulotomy distraction differed with sex (p<0.0001) and traction method (p<0.0056), with female and peroneal post-distracted patients exhibiting higher distraction magnitudes. All force values along the intervention trajectory (before and after venting, before and after capsulotomy) differed with respect to sex and traction method, but not with hamstring flexibility (Table1). Male patients and post-distracted patients exhibited higher forces. Distraction-traction ratios (distraction achieved per unit force applied) differed with respect to sex, traction method, and hamstring flexibility at all interventions – except for the after-capsulotomy ratio, which was unaffected by hamstring flexibility (Table 1). Higher values (more distraction achieved per unit force) were seen in more flexible patients, female patients, and patients distracted via the postless method. The differences between ratios before and after an intervention differed with respect to sex for venting (p<0.0106), and both sex and traction method for capsulotomy (sex: p<0.0001 traction: p<0.0379), representing more distraction achieved per unit force after capsulotomy in the post-distracted group, and for female patients at both interventions. Conclusions: The distraction results indicate that the posted and postless methods of traction application do not differ significantly in the magnitude of distraction achieved (except after capsulotomy), but depend more on patient flexibility. The fact that after-capsulotomy distractions are larger in the post-distracted group may point to differences in soft tissue strain patterns between traction application methods. Traction forces are higher in post-distracted group but yield lower distraction distances per unit force than the postless method overall; the exception to this pattern is the ratio taken after capsulotomy, which is higher in the post-distracted group. Taken together, these results may support a switch to postless methods and invite further investigation into the anatomical and mechanical patterns governing capsular integrity.
- 1 January 2019
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 9 (4) , e0134
Traumatic Pediatric Quadriceps Rupture After Medial Patellofemoral Ligament Reconstruction
Case: A healthy 14-year-old boy, who presented with recurrent patellar instability, underwent medial patellofemoral ligament (MPFL) reconstruction. Four weeks following this operation, the patient slipped and fell while wearing his knee brace and was found to have sustained a quadriceps tendon rupture. Conclusions: We present a case of a rare, previously undescribed complication following an MPFL reconstruction in a young athlete. The etiology of this particular injury pattern may be due to a disruption of the vascular supply to the superior pole of the patella. Orthopaedic surgeons performing these reconstructions should be aware of this unusual complication.
- 1 January 2019
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 9 (4) , e0134
Traumatic Pediatric Quadriceps Rupture After Medial Patellofemoral Ligament Reconstruction
Case: A healthy 14-year-old boy, who presented with recurrent patellar instability, underwent medial patellofemoral ligament (MPFL) reconstruction. Four weeks following this operation, the patient slipped and fell while wearing his knee brace and was found to have sustained a quadriceps tendon rupture. Conclusions: We present a case of a rare, previously undescribed complication following an MPFL reconstruction in a young athlete. The etiology of this particular injury pattern may be due to a disruption of the vascular supply to the superior pole of the patella. Orthopaedic surgeons performing these reconstructions should be aware of this unusual complication.
- Open Access
- 24 May 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 476 (7) , 1494-1502
Revisiting the Anteroinferior Iliac Spine: Is the Subspine Pathologic? A Clinical and Radiographic Evaluation
Background: Subspine impingement is a recognized source of extraarticular hip impingement. Although CT-based classification systems have been described, to our knowledge, no study has evaluated the morphology of the anteroinferior iliac spine (AIIS) with plain radiographs nor to our knowledge has any study compared its appearance between plain radiographs and CT scan and correlated AIIS morphology with physical findings. Previous work has suggested a correlation of AIIS morphology and hip ROM but this has not been clinically validated. Furthermore, if plain radiographs can be found to adequately screen for AIIS morphology, CT could be selectively used, limiting radiation exposure. Questions/purposes: The purposes of this study were (1) to determine the prevalence of AIIS subtypes in a cohort of patients with symptomatic femoroacetabular impingement; (2) to compare AP pelvis and false profile radiographs with three-dimensional (3-D) CT classification; and (3) to correlate the preoperative hip physical examination with AIIS subtypes. Methods: A retrospective study of patients undergoing primary hip arthroscopy for femoroacetabular impingement syndrome was performed. Between February 2013 and November 2016, 601 patients underwent hip arthroscopy. To be included here, each patient had to have undergone a primary hip arthroscopy for the diagnosis of femoroacetabular impingement syndrome. Each patient needed to have an interpretable set of plain radiographs consisting of weightbearing AP pelvis and false profile radiographs as well as full documentation of physical findings in the medical record. Patients who additionally had a CT scan with 3-D reconstructions were included as well. During the period in question, it was the preference of the treating surgeon whether a preoperative CT scan was obtained. A total of 145 of 601 (24%) patients were included in the analysis; of this cohort, 54% (78 of 145) had a CT scan and 63% (92 of 145) were women with a mean age of 31 ± 10 years. The AIIS was classified first on patients in whom the 3-D CT scan was available based on a previously published 3-D CT classification. The AIIS was then classified by two orthopaedic surgeons (TGM, MRK) on AP and false profile radiographs based on the position of its inferior margin to a line at the lateral aspect of the acetabular sourcil normal to vertical. Type I was above, Type II at the level, and Type III below this line. There was fair interrater agreement for AP pelvis (κ = 0.382; 95% confidence interval [CI], 0.239-0.525), false profile (κ = 0.372; 95% CI, 0.229-0.515), and 3-D CT (κ = 0.325; 95% CI, 0.156-0.494). There was moderate to almost perfect intraobserver repeatability for AP pelvis (κ = 0.516; 95% CI, 0.284-0.748), false profile (κ = 0.915; 95% CI, 0.766-1.000), and 3-D CT (κ = 0.915; 95% CI, 0.766-1.000). The plane radiographs were then compared with the 3-D CT scan classification and accuracy, defined as the proportion of correct classification out of total classifications. Preoperative hip flexion, internal rotation, external rotation, flexion adduction, internal rotation, subspine, and Stinchfield physical examination tests were compared with classification of the AIIS on 3-D CT. Finally, preoperative hip flexion, internal rotation, and external rotation were compared with preoperative lateral center-edge angle and alpha angle. Results: The prevalence of AIIS was 56% (44 of 78) Type I, 39% (30 of 78) Type II, and 5% (four of 78) Type III determined from the 3-D CT classification. For the plain radiographic classification, the distribution of AIIS morphology was 64% (93 of 145) Type I, 32% (46 of 145) Type II, and 4% (six of 145) Type III on AP pelvis and 49% (71 of 145) Type I, 48% (70 of 145) Type II, and 3% (four of 145) Type III on false profile radiographs. False profile radiographs were more accurate than AP pelvis radiographs for classification when compared against the gold standard of 3-D CT at 98% (95% CI, 96-100) versus 80% (95% CI, 75-85). The false profile radiograph had better sensitivity for Type II (97% versus 47%, p < 0.001) and specificity for Types I and II AIIS (97% versus 53%, p < 0.001; 98% versus 90%, p = 0.046) morphology compared with AP pelvis radiographs. There was no correlation between AIIS type as determined by 3-D CT scan and hip flexion (rs = -0.115, p = 0.377), internal rotation (rs = 0.070, p = 0.548), flexion adduction internal rotation (U = 72.00, p = 0.270), Stinchfield (U = 290.50, p = 0.755), or subspine tests (U = 319.00, p = 0.519). External rotation was weakly correlated (rs = 0.253, p = 0.028) with AIIS subtype. Alpha angle was negatively correlated with hip flexion (r = -0.387, p = 0.002) and external rotation (r = -0.238, p = 0.043) and not correlated with internal rotation (r = -0.068, p = 0.568). Conclusions: The findings in this study suggest the false profile radiograph is superior to an AP radiograph of the pelvis in evaluating AIIS morphology. Neither preoperative hip internal rotation nor impingement tests correlate with AIIS type as previously suggested questioning the utility of the AIIS classification system in identifying pathologic AIIS anatomy. Level of Evidence: Level III, diagnostic study.
- 24 May 2018
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 476 (7) , 1494-1502
Open AccessRevisiting the Anteroinferior Iliac Spine: Is the Subspine Pathologic? A Clinical and Radiographic Evaluation
Background: Subspine impingement is a recognized source of extraarticular hip impingement. Although CT-based classification systems have been described, to our knowledge, no study has evaluated the morphology of the anteroinferior iliac spine (AIIS) with plain radiographs nor to our knowledge has any study compared its appearance between plain radiographs and CT scan and correlated AIIS morphology with physical findings. Previous work has suggested a correlation of AIIS morphology and hip ROM but this has not been clinically validated. Furthermore, if plain radiographs can be found to adequately screen for AIIS morphology, CT could be selectively used, limiting radiation exposure. Questions/purposes: The purposes of this study were (1) to determine the prevalence of AIIS subtypes in a cohort of patients with symptomatic femoroacetabular impingement; (2) to compare AP pelvis and false profile radiographs with three-dimensional (3-D) CT classification; and (3) to correlate the preoperative hip physical examination with AIIS subtypes. Methods: A retrospective study of patients undergoing primary hip arthroscopy for femoroacetabular impingement syndrome was performed. Between February 2013 and November 2016, 601 patients underwent hip arthroscopy. To be included here, each patient had to have undergone a primary hip arthroscopy for the diagnosis of femoroacetabular impingement syndrome. Each patient needed to have an interpretable set of plain radiographs consisting of weightbearing AP pelvis and false profile radiographs as well as full documentation of physical findings in the medical record. Patients who additionally had a CT scan with 3-D reconstructions were included as well. During the period in question, it was the preference of the treating surgeon whether a preoperative CT scan was obtained. A total of 145 of 601 (24%) patients were included in the analysis; of this cohort, 54% (78 of 145) had a CT scan and 63% (92 of 145) were women with a mean age of 31 ± 10 years. The AIIS was classified first on patients in whom the 3-D CT scan was available based on a previously published 3-D CT classification. The AIIS was then classified by two orthopaedic surgeons (TGM, MRK) on AP and false profile radiographs based on the position of its inferior margin to a line at the lateral aspect of the acetabular sourcil normal to vertical. Type I was above, Type II at the level, and Type III below this line. There was fair interrater agreement for AP pelvis (κ = 0.382; 95% confidence interval [CI], 0.239-0.525), false profile (κ = 0.372; 95% CI, 0.229-0.515), and 3-D CT (κ = 0.325; 95% CI, 0.156-0.494). There was moderate to almost perfect intraobserver repeatability for AP pelvis (κ = 0.516; 95% CI, 0.284-0.748), false profile (κ = 0.915; 95% CI, 0.766-1.000), and 3-D CT (κ = 0.915; 95% CI, 0.766-1.000). The plane radiographs were then compared with the 3-D CT scan classification and accuracy, defined as the proportion of correct classification out of total classifications. Preoperative hip flexion, internal rotation, external rotation, flexion adduction, internal rotation, subspine, and Stinchfield physical examination tests were compared with classification of the AIIS on 3-D CT. Finally, preoperative hip flexion, internal rotation, and external rotation were compared with preoperative lateral center-edge angle and alpha angle. Results: The prevalence of AIIS was 56% (44 of 78) Type I, 39% (30 of 78) Type II, and 5% (four of 78) Type III determined from the 3-D CT classification. For the plain radiographic classification, the distribution of AIIS morphology was 64% (93 of 145) Type I, 32% (46 of 145) Type II, and 4% (six of 145) Type III on AP pelvis and 49% (71 of 145) Type I, 48% (70 of 145) Type II, and 3% (four of 145) Type III on false profile radiographs. False profile radiographs were more accurate than AP pelvis radiographs for classification when compared against the gold standard of 3-D CT at 98% (95% CI, 96-100) versus 80% (95% CI, 75-85). The false profile radiograph had better sensitivity for Type II (97% versus 47%, p < 0.001) and specificity for Types I and II AIIS (97% versus 53%, p < 0.001; 98% versus 90%, p = 0.046) morphology compared with AP pelvis radiographs. There was no correlation between AIIS type as determined by 3-D CT scan and hip flexion (rs = -0.115, p = 0.377), internal rotation (rs = 0.070, p = 0.548), flexion adduction internal rotation (U = 72.00, p = 0.270), Stinchfield (U = 290.50, p = 0.755), or subspine tests (U = 319.00, p = 0.519). External rotation was weakly correlated (rs = 0.253, p = 0.028) with AIIS subtype. Alpha angle was negatively correlated with hip flexion (r = -0.387, p = 0.002) and external rotation (r = -0.238, p = 0.043) and not correlated with internal rotation (r = -0.068, p = 0.568). Conclusions: The findings in this study suggest the false profile radiograph is superior to an AP radiograph of the pelvis in evaluating AIIS morphology. Neither preoperative hip internal rotation nor impingement tests correlate with AIIS type as previously suggested questioning the utility of the AIIS classification system in identifying pathologic AIIS anatomy. Level of Evidence: Level III, diagnostic study.