Bin Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bin Yang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yang Gao
College of Mechatronic Engineering, North Minzu University, Yinchuan 750021, China
3 shared publications - Ruimin Wang
Mechanical Engineering Department, University of Kansas, Lawrence, KS 66045, USA
2 shared publications - Zhifeng Liu
School of Mechanical Engineering, Hefei University of Technology, Hefei 230002, China
2 shared publications - Lin Liu
Department of Mechanical Engineering, University of Kansas, 3138 Learned Hall, 1530 W. 15th Street, Lawrence, KS 66045-4709, USA
1 shared publication - Xinyue Liu
School of Electrical and Information Engineering, North Minzu University, Yinchuan 750021, China
1 shared publication - Yaru Feng
School of Electrical and Information Engineering, North Minzu University, Yinchuan 750021, China
1 shared publication
Latest Publications
- Open Access
- 25 May 2025
- Published by MDPI AG in Magnetochemistry
- Vol. 11 (6) , 46
Research on 3D Magnetic Memory Signals Induced by Circular Hole Defects
Metal magnetic memory testing technology can not only detect macroscopic defects in ferromagnetic materials but also rapidly and conveniently detect early damage and stress concentration areas of components. Therefore, it is widely used in the nondestructive testing of ferromagnetic materials. However, the mechanism of magnetic memory detection is not yet clarified, and experimental research is unsystematic. Previous studies mainly focus on the normal and tangential components of magnetic memory signals (MMSs), and the third directional component is rarely considered, resulting in problems such as missed detection and misjudgement in practical applications. In this research, specimens without and with a circular hole defect were designed, and the correlation between the 3D MMS and the defect size, as well as the applied load, were investigated using tensile tests. Magnetic parameters were defined to characterize the stress and defect-induced abnormal magnetic change. The effects of applied load and defect size on magnetic parameters were discussed. The experimental results showed that the peak–valley difference in the 3D MMS increases with increasing load and defect size, and the peak–valley spacing in the 3D MMS is not influenced by applied load but increases with increasing defect size. The 3D MMS gradient exhibits a good correlation with the equivalent stress along the loading direction. Additionally, the applied load and defect size were quantitatively evaluated by utilizing the Lissajous figure area generated from the X and Z components of the 3D MMS. Finally, a nonlinear fitting equation for defect size evaluation was presented. This study can provide a theoretical basis for the quantitative detection and evaluation of defect size and stress in engineering applications.
- 25 May 2025
- Published by MDPI AG in Magnetochemistry
- Vol. 11 (6) , 46
Open AccessResearch on 3D Magnetic Memory Signals Induced by Circular Hole Defects
Metal magnetic memory testing technology can not only detect macroscopic defects in ferromagnetic materials but also rapidly and conveniently detect early damage and stress concentration areas of components. Therefore, it is widely used in the nondestructive testing of ferromagnetic materials. However, the mechanism of magnetic memory detection is not yet clarified, and experimental research is unsystematic. Previous studies mainly focus on the normal and tangential components of magnetic memory signals (MMSs), and the third directional component is rarely considered, resulting in problems such as missed detection and misjudgement in practical applications. In this research, specimens without and with a circular hole defect were designed, and the correlation between the 3D MMS and the defect size, as well as the applied load, were investigated using tensile tests. Magnetic parameters were defined to characterize the stress and defect-induced abnormal magnetic change. The effects of applied load and defect size on magnetic parameters were discussed. The experimental results showed that the peak–valley difference in the 3D MMS increases with increasing load and defect size, and the peak–valley spacing in the 3D MMS is not influenced by applied load but increases with increasing defect size. The 3D MMS gradient exhibits a good correlation with the equivalent stress along the loading direction. Additionally, the applied load and defect size were quantitatively evaluated by utilizing the Lissajous figure area generated from the X and Z components of the 3D MMS. Finally, a nonlinear fitting equation for defect size evaluation was presented. This study can provide a theoretical basis for the quantitative detection and evaluation of defect size and stress in engineering applications.
- Open Access
Magnetization Changes Induced by Stress Noncoaxial with the Magnetic Field in a Low-Carbon Steel
Ferromagnetic materials are widely used in the manufacturing of key parts of energy equipment, due to their good mechanical properties, such as in nuclear power and pipes. Mechanical stress exists inside of these key parts during operation. Stress can be estimated indirectly by nondestructive testing methods that measure the magnetic flux leakage signals on the surface of the structure, which is of great importance for ensuring the safety of the equipment. However, the physical mechanism of the stress and magnetic field in the magnetization of ferromagnetic materials is still unclear, leading to limited applications of the technique in practice. In this paper, magnetization tests were carried out to investigate magnetization changes under the coupling effect of stress and a noncoaxial magnetic field. Two identical Q195 low-carbon steel specimens were tested. Specimen 1 was subjected to magnetic field values successively increasing from 0 A/m to 6000 A/m under constant uniaxial tension at different angles θ between the field and stress axis. Specimen 2 was subjected to the same magnetic field under different levels of stress at an angle of 0°. The surface magnetic induction B of the specimens was measured and analyzed at each angle of stress–field orientation and at different levels of stress. It was found that there was a difference in the direction between the B and the magnetic field H at different angles θ. The magnetization curves correlated to the angle θ and the stress levels. The behavior of the derived maximum differential permeability and maximum magnetic induction could be used for the nondestructive evaluation of stress magnitude and direction in materials already in service.
Open AccessMagnetization Changes Induced by Stress Noncoaxial with the Magnetic Field in a Low-Carbon Steel
Ferromagnetic materials are widely used in the manufacturing of key parts of energy equipment, due to their good mechanical properties, such as in nuclear power and pipes. Mechanical stress exists inside of these key parts during operation. Stress can be estimated indirectly by nondestructive testing methods that measure the magnetic flux leakage signals on the surface of the structure, which is of great importance for ensuring the safety of the equipment. However, the physical mechanism of the stress and magnetic field in the magnetization of ferromagnetic materials is still unclear, leading to limited applications of the technique in practice. In this paper, magnetization tests were carried out to investigate magnetization changes under the coupling effect of stress and a noncoaxial magnetic field. Two identical Q195 low-carbon steel specimens were tested. Specimen 1 was subjected to magnetic field values successively increasing from 0 A/m to 6000 A/m under constant uniaxial tension at different angles θ between the field and stress axis. Specimen 2 was subjected to the same magnetic field under different levels of stress at an angle of 0°. The surface magnetic induction B of the specimens was measured and analyzed at each angle of stress–field orientation and at different levels of stress. It was found that there was a difference in the direction between the B and the magnetic field H at different angles θ. The magnetization curves correlated to the angle θ and the stress levels. The behavior of the derived maximum differential permeability and maximum magnetic induction could be used for the nondestructive evaluation of stress magnitude and direction in materials already in service.
- Open Access
Effect of Stress on Variations in the Magnetic Field of Ferromagnetic Steel under a Constant DC Magnetic Field
In this paper, variations in the normal component of the magnetic field BZ on the surface of Q195 steel specimens produced by simultaneous application of noncoaxial DC magnetic field and stress were studied by tensile tests. It was found that there was no shift in the direction of BZ variations when the specimens were magnetized parallel to stress, whereas the direction of BZ variations shifted a slight angle relative to the DC magnetic field when the specimens were magnetized perpendicular to stress. The amplitude of BZ increased with stress from 0 MPa to 120 MPa when the stress was parallel to the DC magnetic field. On the contrary, the amplitude of BZ decreased with stress from 0 MPa to 120 MPa when the stress was perpendicular to the DC magnetic field. The mechanisms underlying the experimental characteristics are also discussed. This research provides the possibility for quantitative inspection of the stress in ferromagnetic steels using surface magnetic field measurements.
Open AccessEffect of Stress on Variations in the Magnetic Field of Ferromagnetic Steel under a Constant DC Magnetic Field
In this paper, variations in the normal component of the magnetic field BZ on the surface of Q195 steel specimens produced by simultaneous application of noncoaxial DC magnetic field and stress were studied by tensile tests. It was found that there was no shift in the direction of BZ variations when the specimens were magnetized parallel to stress, whereas the direction of BZ variations shifted a slight angle relative to the DC magnetic field when the specimens were magnetized perpendicular to stress. The amplitude of BZ increased with stress from 0 MPa to 120 MPa when the stress was parallel to the DC magnetic field. On the contrary, the amplitude of BZ decreased with stress from 0 MPa to 120 MPa when the stress was perpendicular to the DC magnetic field. The mechanisms underlying the experimental characteristics are also discussed. This research provides the possibility for quantitative inspection of the stress in ferromagnetic steels using surface magnetic field measurements.