Xingxing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xingxing Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Weidong Li
School of Mathematics and Statistics, Yunnan University, Kunming, People’s Republic of China
2 shared publications - Xuejie Zhang
School of Information Science and Engineering, Yunnan University, Kunming, China
2 shared publications - Cheng Pan
School of Electrical Engineering and Automation, State Key Laboratory of Power Grid Environmental Protection, Wuhan University, Wuhan, China
1 shared publication - Dibo Wang
Electric Power Research Institute, China Southern Power Grid, Guangzhou 510623, China
1 shared publication - Ju Tang
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
1 shared publication - Ran Zhuo
Department of Mathematics, Shanghai Normal University, Shanghai, P. R. China
1 shared publication
Latest Publications
- 6 July 2026
- Published by Elsevier in Future Generation Computer Systems
- Vol. 185
Fairness-efficiency tradeoffs in multiresource allocation for cloud–edge collaborative computing
- 6 July 2026
- Published by Elsevier in Future Generation Computer Systems
- Vol. 185
Fairness-efficiency tradeoffs in multiresource allocation for cloud–edge collaborative computing
- 10 December 2022
- Published by Springer Nature
- p. 248-262
Multi-resource Allocation in Mobile Edge Computing Systems: A Trade-Off on Fairness and Efficiency
- 10 December 2022
- Published by Springer Nature
- p. 248-262
Multi-resource Allocation in Mobile Edge Computing Systems: A Trade-Off on Fairness and Efficiency
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 25 (5) , 1605-1613
Impact of oil velocity on partial discharge characteristics induced by bubbles in transformer oil
Bubble is a typical insulation defect in transformer oil, which can easily initiate partial discharge (PD) during the operation of transformer. Moreover, it migrates along with the oil flow and may be deformed due to the forced oil circulation and temperature difference within transformer bulk, leading to the complexity of PD characteristics and PD mechanism. However, the understanding of to this phenomenon is not clear. In order to identify it, finite element method was employed to simulate the movement process and deformation of bubbles, as well as electric field distribution under the conditions with different oil flow rates. In addition, numerous experiments were performed, mainly including the change of PD ϕ-q and ϕ-n patterns with oil flow rates. By comparing the simulation and experimental results, it is found that PDs are mainly concentrated in the negative half-cycle. Electric force causes bubbles to stretch along the electric field direction. At the stationary condition, bubbles eventually exhibit horizontal stretching and cause maximum electric field distortion. However, bubbles eventually exhibit vertical stretching in flowing oil. Flowing oil can significantly reduce PD intensity. The PD intensity declines rapidly with the increase of the flow velocity, and then increases slowly.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 25 (5) , 1605-1613
Impact of oil velocity on partial discharge characteristics induced by bubbles in transformer oil
Bubble is a typical insulation defect in transformer oil, which can easily initiate partial discharge (PD) during the operation of transformer. Moreover, it migrates along with the oil flow and may be deformed due to the forced oil circulation and temperature difference within transformer bulk, leading to the complexity of PD characteristics and PD mechanism. However, the understanding of to this phenomenon is not clear. In order to identify it, finite element method was employed to simulate the movement process and deformation of bubbles, as well as electric field distribution under the conditions with different oil flow rates. In addition, numerous experiments were performed, mainly including the change of PD ϕ-q and ϕ-n patterns with oil flow rates. By comparing the simulation and experimental results, it is found that PDs are mainly concentrated in the negative half-cycle. Electric force causes bubbles to stretch along the electric field direction. At the stationary condition, bubbles eventually exhibit horizontal stretching and cause maximum electric field distortion. However, bubbles eventually exhibit vertical stretching in flowing oil. Flowing oil can significantly reduce PD intensity. The PD intensity declines rapidly with the increase of the flow velocity, and then increases slowly.