Filippo Medeghini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Filippo Medeghini has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Peter Mark
Institute of Concrete Structures, Faculty of Civil and Environmental Engineering Ruhr University Bochum Bochum Germany
4 shared publications - Giovanni Plizzari
University of Brescia
3 shared publications - Giuseppe Tiberti
Department of Civil, Environmental, Architectural Engineering and Mathematics University of Brescia Brescia Italy
3 shared publications - Jajnabalkya Guhathakurta
Department of Computational Imaging Systems Institute of Computer Architecture and Computer Engineering, University of Stuttgart Stuttgart Germany
2 shared publications Sven Simon
Department of Computational Imaging Systems Institute of Computer Architecture and Computer Engineering, University of Stuttgart Stuttgart Germany
2 shared publicationsAlessandro Palmeri
Anchors Application Engineering, Hilti Entwicklungsgesellschaft, Hiltistraße 6, 86916 Kaufering, Germany
1 shared publication
Latest Publications
- Open Access
- 26 August 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Tailoring SFRC to mechanical needs: Full-scale experiments with optimized hybrid SFRC composition and fiber alignment to stress path
- 26 August 2025
- Published by Elsevier in Engineering Structures
- Vol. 343
Open AccessTailoring SFRC to mechanical needs: Full-scale experiments with optimized hybrid SFRC composition and fiber alignment to stress path
- Open Access
- 13 June 2025
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 409, 11003
An efficient post-installed shear-strengthening solution for RC structural elements
Much of Europe’s building stock and infrastructure were constructed in the last century, often before strict design standards were adopted. Ageing materials, increased loading demands, sustainability requirements, and cost-efficiency goals further support the need for the retrofitting of existing reinforced concrete (RC) structures rather than their demolition and replacement. Motivated by these considerations, a new post-installed (PI) shear strengthening system was developed. In this solution, threaded rods bonded in drilled holes act as a substitute for traditional cast-in (CI) stirrups. An extensive experimental campaign consisting of several large-scale beams was executed to rigorously assess and quantify the new system’s performance, leading to a “general construction technique permit” in Germany (Allgemeine Bauartgenehmigung, aBG). The campaign investigated experimentally the main parameters that influence the shear resistance in RC beams, namely: shear and longitudinal reinforcement ratios, effective depth, and concrete compressive strength. The longitudinal rebars in tension were instrumented, allowing detailed tracking of strains during all tests. Results were compared with current Eurocode 2 provisions for concrete members with shear reinforcement, demonstrating that the shear resistance mechanism of the new PI solution closely matches that of conventional CI stirrups, with similar structural performance, highlighting its effectiveness as an efficient retrofitting solution.
- 13 June 2025
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 409, 11003
Open AccessAn efficient post-installed shear-strengthening solution for RC structural elements
Much of Europe’s building stock and infrastructure were constructed in the last century, often before strict design standards were adopted. Ageing materials, increased loading demands, sustainability requirements, and cost-efficiency goals further support the need for the retrofitting of existing reinforced concrete (RC) structures rather than their demolition and replacement. Motivated by these considerations, a new post-installed (PI) shear strengthening system was developed. In this solution, threaded rods bonded in drilled holes act as a substitute for traditional cast-in (CI) stirrups. An extensive experimental campaign consisting of several large-scale beams was executed to rigorously assess and quantify the new system’s performance, leading to a “general construction technique permit” in Germany (Allgemeine Bauartgenehmigung, aBG). The campaign investigated experimentally the main parameters that influence the shear resistance in RC beams, namely: shear and longitudinal reinforcement ratios, effective depth, and concrete compressive strength. The longitudinal rebars in tension were instrumented, allowing detailed tracking of strains during all tests. Results were compared with current Eurocode 2 provisions for concrete members with shear reinforcement, demonstrating that the shear resistance mechanism of the new PI solution closely matches that of conventional CI stirrups, with similar structural performance, highlighting its effectiveness as an efficient retrofitting solution.
- Open Access
- 17 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (1) , 481-500
Fiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review
Fiber orientation is of paramount importance for the design of fiber‐reinforced concrete (FRC) structural elements, because it markedly influences the postcracking properties of such material. For this reason, structural codes introduce orientation factors which aim to correlate the real mechanical properties of the structural element with the ones determined from standard beams. Although the need of considering fiber orientation in design codes is commonly accepted, the orientation factors are still based on a limited number of research studies, raising the need to better determine fiber orientation to improve the current standards and support the design process of FRC elements. In this research, a steel fiber‐reinforced concrete (SFRC) with a hybrid system of macro and microfibers is steered into a broad range of fiber orientations and cast into standard beams. Besides measuring the mechanical performance of these SFRC beams, three different methods for assessing fiber orientation are employed, namely electromagnetic induction, image analysis, and micro‐computed tomography. The comparison between the outcomes of the different methods provides detailed information about the accuracy and suitability of each method, considering the corresponding domain of applicability at structural level. Finally, a critical review of the most common 2D and 3D orientation parameters found in literature is performed, and the equations are adapted to account for the hybrid system of fibers.
- 17 September 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (1) , 481-500
Open AccessFiber orientation and orientation factors in steel fiber‐reinforced concrete beams with hybrid fibers: A critical review
Fiber orientation is of paramount importance for the design of fiber‐reinforced concrete (FRC) structural elements, because it markedly influences the postcracking properties of such material. For this reason, structural codes introduce orientation factors which aim to correlate the real mechanical properties of the structural element with the ones determined from standard beams. Although the need of considering fiber orientation in design codes is commonly accepted, the orientation factors are still based on a limited number of research studies, raising the need to better determine fiber orientation to improve the current standards and support the design process of FRC elements. In this research, a steel fiber‐reinforced concrete (SFRC) with a hybrid system of macro and microfibers is steered into a broad range of fiber orientations and cast into standard beams. Besides measuring the mechanical performance of these SFRC beams, three different methods for assessing fiber orientation are employed, namely electromagnetic induction, image analysis, and micro‐computed tomography. The comparison between the outcomes of the different methods provides detailed information about the accuracy and suitability of each method, considering the corresponding domain of applicability at structural level. Finally, a critical review of the most common 2D and 3D orientation parameters found in literature is performed, and the equations are adapted to account for the hybrid system of fibers.
- Open Access
- 3 February 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 5150-5166
Material reduced tunnel lining segments for moderately swelling soils
Tunnels in unfavorable ground conditions are exposed to high internal stresses due to localized loading at the outer face. Addition of extra layers of compressible material as a countermeasure needs more material and greater excavation volumes which is in conflict to the global goals of CO2 reduction. Thus, two alternative types of segments with higher bearing capacities are proposed that allow for lining thickness reduction. They are derived from multi‐load topology optimization considering relevant load cases during construction and in service. The first design incorporates centered recesses that maximize segmental stiffness. The second shifts the recesses to the outer face increasing their potential to absorb deformation. Two prototypes of each type are fabricated from high performance steel fiber reinforced concrete. Experiments show that a concrete reduction of up to 55.2% is achieved with respect to a conventional design. The volume savings give space for layers of radially compressible material.
- 3 February 2023
- Published by Wiley in Structural Concrete
- Vol. 24 (4) , 5150-5166
Open AccessMaterial reduced tunnel lining segments for moderately swelling soils
Tunnels in unfavorable ground conditions are exposed to high internal stresses due to localized loading at the outer face. Addition of extra layers of compressible material as a countermeasure needs more material and greater excavation volumes which is in conflict to the global goals of CO2 reduction. Thus, two alternative types of segments with higher bearing capacities are proposed that allow for lining thickness reduction. They are derived from multi‐load topology optimization considering relevant load cases during construction and in service. The first design incorporates centered recesses that maximize segmental stiffness. The second shifts the recesses to the outer face increasing their potential to absorb deformation. Two prototypes of each type are fabricated from high performance steel fiber reinforced concrete. Experiments show that a concrete reduction of up to 55.2% is achieved with respect to a conventional design. The volume savings give space for layers of radially compressible material.
- Open Access
- 10 December 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (10) , 1-18
Steered fiber orientation: correlating orientation and residual tensile strength parameters of SFRC
Adding steel fibers to concrete improves the post-cracking tensile strength of the composite material due to fibers bridging the cracks. The residual performance of the material is influenced by fiber type, content and orientation with respect to the crack plane. The latter is a main issue in fiber-reinforced concrete elements, since it significantly influences the structural behavior. The aim of this research is to develop a tailor-made composite material and casting method to orient fibers in order to optimize the performance of the material for structural applications. To this aim, a mechanized concreting device that induces such preferred fiber orientation is designed and fabricated. It uses vibration and a series of narrow channels to guide and orient fibers. A composite with oriented fibers is produced using a hybrid system of macro and micro fibers and high-performance concrete. From the same concrete batch, specimens are cast both with and without the fiber orientation device, obtaining different levels of fiber orientation. Three-point bending tests are performed to measure and compare the residual tensile strength capacities with standard specimens cast according to EN 14651. Elements with favorable fiber orientation show a significant increase in residual tensile strength with respect to the standard beams. Finally, computed tomography and an electromagnetic induction method are employed to better assess the orientation and distribution of fibers in the beams. Their results are in good agreement and enable to link the residual tensile strength parameters with fiber orientation.
- 10 December 2022
- Published by Springer Nature in Materials and Structures
- Vol. 55 (10) , 1-18
Open AccessSteered fiber orientation: correlating orientation and residual tensile strength parameters of SFRC
Adding steel fibers to concrete improves the post-cracking tensile strength of the composite material due to fibers bridging the cracks. The residual performance of the material is influenced by fiber type, content and orientation with respect to the crack plane. The latter is a main issue in fiber-reinforced concrete elements, since it significantly influences the structural behavior. The aim of this research is to develop a tailor-made composite material and casting method to orient fibers in order to optimize the performance of the material for structural applications. To this aim, a mechanized concreting device that induces such preferred fiber orientation is designed and fabricated. It uses vibration and a series of narrow channels to guide and orient fibers. A composite with oriented fibers is produced using a hybrid system of macro and micro fibers and high-performance concrete. From the same concrete batch, specimens are cast both with and without the fiber orientation device, obtaining different levels of fiber orientation. Three-point bending tests are performed to measure and compare the residual tensile strength capacities with standard specimens cast according to EN 14651. Elements with favorable fiber orientation show a significant increase in residual tensile strength with respect to the standard beams. Finally, computed tomography and an electromagnetic induction method are employed to better assess the orientation and distribution of fibers in the beams. Their results are in good agreement and enable to link the residual tensile strength parameters with fiber orientation.