Federica Semproni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Federica Semproni has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Menciassi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
6 shared publications - Veronica Iacovacci
The Biorobotics Institute Scuola Superiore Sant’Anna Viale Rinaldo Piaggio 34 56025 Pontedera Italy
5 shared publications - Michele Ibrahimi
The BioRobotics Institute Scuola Superiore Sant’Anna Piazza Martiri della Libertà 33 56127 Pisa Italy
2 shared publications - Alessio Capecchi
BioRobotics Institute, Scuola SuperioreSant’Anna, Pontedera (Pisa), Italy
1 shared publication Colli Andrea
Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine University of Pisa Pisa Italy
1 shared publication- Gastone Ciuti
Scuola Superiore Sant’Anna
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by Wiley in Advanced Intelligent Systems
Implantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies
Cardiovascular diseases remain the leading cause of mortality worldwide, driving the need for implantable technologies capable of repairing, supporting, replacing, and monitoring cardiovascular functions. Current cardiovascular technologies are commonly classified according to anatomical target or invasiveness, limiting direct comparison of how different systems interact with blood and tissues. We present a comparative review based on the distinction between intracardiovascular systems, directly exposed to blood flow, and extracardiovascular systems, primarily interacting with surrounding tissues. A total of 107 devices (77 actuation and 30 sensing technologies) across myocardial, vascular, and valvular domains were analyzed through a semiquantitative framework considering blood contact burden, biomimicry, invasiveness, bulkiness, softness, and clinical maturity. Our analysis reveals that clinically established actuation systems remain predominantly rigid and optimized for reliability and high hemodynamic support, whereas emerging soft technologies aim to improve mechanical compatibility with cardiovascular tissues and reduce physiological burden, although they largely remain preclinical. Blood‐contacting devices provide direct hemodynamic control but face major hemocompatibility constraints, while extracardiovascular approaches reduce blood exposure with more complex tissue coupling. Sensing technologies are generally less mature with the preference for minimally invasive monitoring whenever external acquisition is feasible. This review identifies interface‐dependent design trade‐offs and highlights key translational challenges toward adaptive, patient‐specific cardiovascular therapies.
- 27 October 2026
- Published by Wiley in Advanced Intelligent Systems
Open AccessImplantable Systems for Cardiovascular Treatment and Monitoring: Comparative Insights From Intracardiovascular and Extracardiovascular Technologies
Cardiovascular diseases remain the leading cause of mortality worldwide, driving the need for implantable technologies capable of repairing, supporting, replacing, and monitoring cardiovascular functions. Current cardiovascular technologies are commonly classified according to anatomical target or invasiveness, limiting direct comparison of how different systems interact with blood and tissues. We present a comparative review based on the distinction between intracardiovascular systems, directly exposed to blood flow, and extracardiovascular systems, primarily interacting with surrounding tissues. A total of 107 devices (77 actuation and 30 sensing technologies) across myocardial, vascular, and valvular domains were analyzed through a semiquantitative framework considering blood contact burden, biomimicry, invasiveness, bulkiness, softness, and clinical maturity. Our analysis reveals that clinically established actuation systems remain predominantly rigid and optimized for reliability and high hemodynamic support, whereas emerging soft technologies aim to improve mechanical compatibility with cardiovascular tissues and reduce physiological burden, although they largely remain preclinical. Blood‐contacting devices provide direct hemodynamic control but face major hemocompatibility constraints, while extracardiovascular approaches reduce blood exposure with more complex tissue coupling. Sensing technologies are generally less mature with the preference for minimally invasive monitoring whenever external acquisition is feasible. This review identifies interface‐dependent design trade‐offs and highlights key translational challenges toward adaptive, patient‐specific cardiovascular therapies.
- Open Access
- 17 October 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (2)
A Robotic Urinary Bladder Enabling Volume Monitoring and Assisted Micturition
The urinary bladder is considered a highly complex organ, capable not only of storing urine but also of sensing intra‐vesical volume and dynamically expanding and contracting. Consequently, fully replicating its functions following radical cystectomy remains a significant technological challenge. Hereinafter, an implantable robotic bladder is presented that can change shape and expand its internal volume up to 400 mL, based on the amount of urine collected from kidneys, and monitor the volume in real‐time. It can apply on‐demand mechanical compression to assist urination, by means of an origami‐designed enclosure, coupled to miniaturized mechatronic components. In vitro characterization in a human phantom is demonstrated, and volume monitoring is validated following a realistic filling routine. The tests demonstrate successful expansions for collecting urine, with an average volume reconstruction error of 8.4 ± 6.1 mL, and then 99% of the volume is voided in less than 2 min. The work paves the way for developing active robotic solutions and reproducing bladder functions in patients with cancer and organ removal or impairment.
- 17 October 2025
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (2)
Open AccessA Robotic Urinary Bladder Enabling Volume Monitoring and Assisted Micturition
The urinary bladder is considered a highly complex organ, capable not only of storing urine but also of sensing intra‐vesical volume and dynamically expanding and contracting. Consequently, fully replicating its functions following radical cystectomy remains a significant technological challenge. Hereinafter, an implantable robotic bladder is presented that can change shape and expand its internal volume up to 400 mL, based on the amount of urine collected from kidneys, and monitor the volume in real‐time. It can apply on‐demand mechanical compression to assist urination, by means of an origami‐designed enclosure, coupled to miniaturized mechatronic components. In vitro characterization in a human phantom is demonstrated, and volume monitoring is validated following a realistic filling routine. The tests demonstrate successful expansions for collecting urine, with an average volume reconstruction error of 8.4 ± 6.1 mL, and then 99% of the volume is voided in less than 2 min. The work paves the way for developing active robotic solutions and reproducing bladder functions in patients with cancer and organ removal or impairment.
- Open Access
- 28 August 2025
- Published by AIP Publishing in APL Bioengineering
- Vol. 9 (3) , 036114
A fully implantable sensorized artificial urinary bladder to restore continence and fullness monitoring
A fully implantable sensorized organ to replace the natural urinary bladder holds considerable promise for patients undergoing radical cystectomy. Clinical options to restore continence include urine redirection to wearable bags or reconstruction of neobladders from autologous tissues, often with limited capacity. However, none of these approaches can restore patient's ability to perceive bladder fullness, making voiding self-management complex and burdensome. To address these limitations, we introduce the Soft Self-Sensitive Artificial Bladder (S3AB), a fully implantable sensorized organ designed to replace urinary bladder anatomy, as well as continence and fullness monitoring. The S3AB main component is a silicone origami-inspired bladder designed to fit the abdominopelvic cavity. The foldable and soft nature facilitates the maintenance of intravesical pressure below the physiological range, thereby promoting the preservation of renal function over time. The bladder is integrated with a multi-sensor system based on resistive textile sensors featuring durability and functionality throughout repetitive cycles of filling and draining. The sensors demonstrate stability at physiological temperatures. Once isolated from bodily fluids, textile sensors permit to monitor the bladder internal volume leveraging on the origami structure opening during filling, with an estimation accuracy within approximately 12%. Volume monitoring allows warning the patient when the maximum capacity is almost reached, thus making possible a natural micturition management. S3AB proved efficient in restoring urine collection and filling state monitoring upon successful implantation in a large animal model.
- 28 August 2025
- Published by AIP Publishing in APL Bioengineering
- Vol. 9 (3) , 036114
Open AccessA fully implantable sensorized artificial urinary bladder to restore continence and fullness monitoring
A fully implantable sensorized organ to replace the natural urinary bladder holds considerable promise for patients undergoing radical cystectomy. Clinical options to restore continence include urine redirection to wearable bags or reconstruction of neobladders from autologous tissues, often with limited capacity. However, none of these approaches can restore patient's ability to perceive bladder fullness, making voiding self-management complex and burdensome. To address these limitations, we introduce the Soft Self-Sensitive Artificial Bladder (S3AB), a fully implantable sensorized organ designed to replace urinary bladder anatomy, as well as continence and fullness monitoring. The S3AB main component is a silicone origami-inspired bladder designed to fit the abdominopelvic cavity. The foldable and soft nature facilitates the maintenance of intravesical pressure below the physiological range, thereby promoting the preservation of renal function over time. The bladder is integrated with a multi-sensor system based on resistive textile sensors featuring durability and functionality throughout repetitive cycles of filling and draining. The sensors demonstrate stability at physiological temperatures. Once isolated from bodily fluids, textile sensors permit to monitor the bladder internal volume leveraging on the origami structure opening during filling, with an estimation accuracy within approximately 12%. Volume monitoring allows warning the patient when the maximum capacity is almost reached, thus making possible a natural micturition management. S3AB proved efficient in restoring urine collection and filling state monitoring upon successful implantation in a large animal model.
- Open Access
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1341-1348
Optimization and Validation of an Artificial Bladder Design Through Finite Element Analysis to Meet Clinical Requirements
Bladder cancer and urinary dysfunctions present significant challenges to patient health and quality of life. Considering that radical cystectomy remains the standard treatment for muscle-invasive bladder cancer, there is an urgent need for the implantation of artificial bladders (ABs). In this study, we present the optimization and validation of a novel, collapsible, origami-based AB through Finite Element Method (FEM) simulations. We evaluated various materials and wall thicknesses to improve unfolding capability and minimize structural stress concentrations. Simulations were conducted under different filling conditions, replicating the in-body constraints posed by surrounding organs. The optimal materialthickness combination, namely MoldStar 15 with a 2:1 wall-tofold ratio, effectively maintained low intravesical pressures during filling (0.5-1.96 kPa), meeting the clinical requirements for renal function preservation. Stress analysis showed Von Mises stresses lower than 2.5 MPa, well below the materials tensile stress limit, thus ensuring the structural integrity of the device. The AB model was validated by comparing FEM simulation results with a physical prototype, showing a pressure difference of approximately 15% and a volumetric overlap deviation under 10%.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (3) , 1341-1348
Open AccessOptimization and Validation of an Artificial Bladder Design Through Finite Element Analysis to Meet Clinical Requirements
Bladder cancer and urinary dysfunctions present significant challenges to patient health and quality of life. Considering that radical cystectomy remains the standard treatment for muscle-invasive bladder cancer, there is an urgent need for the implantation of artificial bladders (ABs). In this study, we present the optimization and validation of a novel, collapsible, origami-based AB through Finite Element Method (FEM) simulations. We evaluated various materials and wall thicknesses to improve unfolding capability and minimize structural stress concentrations. Simulations were conducted under different filling conditions, replicating the in-body constraints posed by surrounding organs. The optimal materialthickness combination, namely MoldStar 15 with a 2:1 wall-tofold ratio, effectively maintained low intravesical pressures during filling (0.5-1.96 kPa), meeting the clinical requirements for renal function preservation. Stress analysis showed Von Mises stresses lower than 2.5 MPa, well below the materials tensile stress limit, thus ensuring the structural integrity of the device. The AB model was validated by comparing FEM simulation results with a physical prototype, showing a pressure difference of approximately 15% and a volumetric overlap deviation under 10%.
- Open Access
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 31287-31296
Urinary Bladder Volume Reconstruction Based on Bioimpedance Measurements: Ex Vivo and In Vivo Validation Through Implanted Patch and Needle Electrodes
Restoring bladder sensation in patients with bladder dysfunctions by performing urinary volume monitoring is an ambitious goal. The bioimpedance technique has shown promising results in wearable solutions but long-term validation and implantable systems are not available, yet. In this work, we propose to implant commercial bioimpedance sensors on bladder walls to perform bladder volume estimation. Two commercial sensor types (Ag/AgCl patch and needle electrodes) were selected to this purpose. Injected current frequency of 1.337 MHz and electrodes pair on the same face of the bladder allowed to correlate the changes in impedance with increasing volumes. Two volume reconstruction algorithms have been proposed, based on the direct correlation between bioimpedance readings and bladder volume (Algorithm A) or bioimpedance readings and inter-electrode distance (Algorithm B, bladder shape approximated to a sphere). For both algorithms, a better fit with a second-degree fitting polynomial was obtained. Algorithm A obtained lower estimation errors with an average of 20.35% and 21.98% (volumes greater than 150 ml) for patch and needle electrodes, respectively. The variations in ions concentration led to a slight deterioration of volume estimation, however the presence of tissues surrounding the bladder did not influence the performance. Although Algorithm B was less affected by the experimental conditions and inter-subject biological variability, it featured higher estimation errors. In vivo validation on suine model showed average errors of 29.36% (volumes greater than 100 ml), demonstrating the potential of the proposed solution and paving the way towards a novel implantable volume monitoring system.
- 14 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (24) , 31287-31296
Open AccessUrinary Bladder Volume Reconstruction Based on Bioimpedance Measurements: Ex Vivo and In Vivo Validation Through Implanted Patch and Needle Electrodes
Restoring bladder sensation in patients with bladder dysfunctions by performing urinary volume monitoring is an ambitious goal. The bioimpedance technique has shown promising results in wearable solutions but long-term validation and implantable systems are not available, yet. In this work, we propose to implant commercial bioimpedance sensors on bladder walls to perform bladder volume estimation. Two commercial sensor types (Ag/AgCl patch and needle electrodes) were selected to this purpose. Injected current frequency of 1.337 MHz and electrodes pair on the same face of the bladder allowed to correlate the changes in impedance with increasing volumes. Two volume reconstruction algorithms have been proposed, based on the direct correlation between bioimpedance readings and bladder volume (Algorithm A) or bioimpedance readings and inter-electrode distance (Algorithm B, bladder shape approximated to a sphere). For both algorithms, a better fit with a second-degree fitting polynomial was obtained. Algorithm A obtained lower estimation errors with an average of 20.35% and 21.98% (volumes greater than 150 ml) for patch and needle electrodes, respectively. The variations in ions concentration led to a slight deterioration of volume estimation, however the presence of tissues surrounding the bladder did not influence the performance. Although Algorithm B was less affected by the experimental conditions and inter-subject biological variability, it featured higher estimation errors. In vivo validation on suine model showed average errors of 29.36% (volumes greater than 100 ml), demonstrating the potential of the proposed solution and paving the way towards a novel implantable volume monitoring system.
- Open Access
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 125626-125651
Bladder Monitoring Systems: State of the Art and Future Perspectives
The lower urinary tract (LUT) is sensitive to nervous system pathologies, injuries and dysfunctions that may lead to the loss or reduction of bladder fullness sensation. Urination assistive devices aimed at supporting bladder emptying and continence control have been proposed so far. However, patients may not perceive the urge to urinate and activate the device accordingly. In this framework, bladder pressure and volume monitoring is crucial and would lead to optimize the use of assistive devices and reduce side effects for the patient. Despite its centrality in restoring LUT functions, urinary bladder monitoring remains not fully explored, yet. In this review paper, we summarize the efforts performed at the clinical and research level towards efficient bladder monitoring. The analysis of the current state of the art enabled to identify the challenges of the field and to draw potential future directions in LUT dysfunction management by engineering solutions. After the introduction of technologies to support urination, a major focus is placed on three groups of monitoring devices, that is, instruments for a clinical setting, wearable devices for continuous and domestic monitoring, and implantable sensors for chronic monitoring. Finally, the main challenges are identified and discussed, highlighting the most crucial points and the main treatment opportunities.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 125626-125651
Open AccessBladder Monitoring Systems: State of the Art and Future Perspectives
The lower urinary tract (LUT) is sensitive to nervous system pathologies, injuries and dysfunctions that may lead to the loss or reduction of bladder fullness sensation. Urination assistive devices aimed at supporting bladder emptying and continence control have been proposed so far. However, patients may not perceive the urge to urinate and activate the device accordingly. In this framework, bladder pressure and volume monitoring is crucial and would lead to optimize the use of assistive devices and reduce side effects for the patient. Despite its centrality in restoring LUT functions, urinary bladder monitoring remains not fully explored, yet. In this review paper, we summarize the efforts performed at the clinical and research level towards efficient bladder monitoring. The analysis of the current state of the art enabled to identify the challenges of the field and to draw potential future directions in LUT dysfunction management by engineering solutions. After the introduction of technologies to support urination, a major focus is placed on three groups of monitoring devices, that is, instruments for a clinical setting, wearable devices for continuous and domestic monitoring, and implantable sensors for chronic monitoring. Finally, the main challenges are identified and discussed, highlighting the most crucial points and the main treatment opportunities.